Schneider PLC intelligent parameter features

Create Date: 2024-8-30 12:03:23|Source: Schneider/Schneider

Characteristic:

1. NEZA PLC (TSX08 series)

EZA series is a small PLC with rich functions, high performance-to-price ratio, small size and strong versatility.

The new generation of handheld programmer - Chinese handheld computer PL707WinCE, supports Chinese interface, whether it is programming, monitoring, debugging or on-site operation, it is very convenient.

Custom Utility Blocks – Put your algorithm directly into the utility block so that it can be used as a standard instruction.

The I/O point can be expanded from 20 points to 80 points.

                            Schneider PLC intelligent parameter features

2. Premium PLC (TSX 57 series)

Medium-sized rack with strong CPU function, fast speed and large memory.

Abundant networking and communication functions. Compact and flexible switching and a wide range of analog modules.

Special modules: high-speed counting module, axis control module, stepping control module, communication module and weighing module.

The programming environment is the same as that of Micro PLC. Schneider PLC Smart Building Life.

More on that
Pressure reducing valves in Schneider instrumentation Pressure reducing valves in Schneider instrumentation

A kind of pressure reducing valve in instrumentation refers to a device used to control the pressure value. Pressure reducing valves are usually used in water-related categories, because from the perspective of the transmission medium, the transmission medium of the equipment is mainly water, but we all know that water is a thing that will ...

Whether an AC circuit breaker can be used in a DC circuit Whether an AC circuit breaker can be used in a DC circuit

Schneider circuit breakers are used to open and break communication loops. The arc extinguishing of the communication system is simple, but the arc extinguishing of the DC system is more difficult. Because the system is different and the arc extinguishing principle is different, there is a big difference in structure and performance between the communication circuit breaker and the DC circuit breaker. Compared with the communication circuit breaker, the DC circuit breaker ...

Instrumentation overhaul points - Schneider Instrumentation overhaul points - Schneider

The test input does not conform to the "short" rule, and the problem is here. 1. Overhaul according to the comparator rules, fit it, the piece is good, and check the periphery; It doesn't fit, the piece is bad. 2. It does not fit the "virtual break" - there are ...

Maintenance of Schneider circuit breakers Maintenance of Schneider circuit breakers

In order to keep the main Schneider circuit breaker in excellent operating condition, it is necessary to strengthen the maintenance management. 1. Insist that the air is moist or unclean, and the pipes are not clean, may have the following consequences: (1) The wet gas is decomposed into mixed gases such as hydrogen and oxygen under the action of electric arc, which damages the ...

Schneider inverter frequency signal source mode Schneider inverter frequency signal source mode

In order for the inverter to operate normally, it must have two basic conditions, that is, the frequency signal and the operating signal, let's talk about the first condition, which is the frequency signal of the inverter. Our intention to use the inverter is to change the ...

THE DIFFERENCE BETWEEN SCHNEIDER CIRCUIT BREAKER EASYPACT AND MASTERPACT THE DIFFERENCE BETWEEN SCHNEIDER CIRCUIT BREAKER EASYPACT AND MASTERPACT

First of all, both are low-voltage circuit breakers (below 1000V) Let's start with Schneider Masterpact, which is a structural circuit breaker. The current rating of the structure varies from 800A ---- 6300A. The Masterpact series is divided into M series and MT series. The M series has been on the market since 1986 and was screened and delisted in 2002.

The difference between Schneider and Siemens PLC The difference between Schneider and Siemens PLC

There are three main differences, namely: different uses, different products, and different characteristics. 1. Different use cases: The programmable manipulator produced by Siemens in Germany is also widely used in China, and has been used in metallurgy, chemical industry, printing production lines and other fields.

Inverter selection and capacity matching - Schneider Inverter selection and capacity matching - Schneider

In addition, it is unscientific to select the inverter body alone, without considering whether the inverter selection and capacity matching are appropriate. ...

The UPS boot panel does not show that the UPS is not working - Schneider The UPS boot panel does not show that the UPS is not working - Schneider

Problem: After the UPS is turned on, there is no display on the panel, and the UPS does not work Problem analysis: Judging from the problem phenomenon, the problem lies in the mains input, the battery and the mains detection part and the battery voltage detection loop: 1. Check ...

Fault check steps for frequency converters - Schneider frequency converters Fault check steps for frequency converters - Schneider frequency converters

1. Check whether the appearance of the inverter is in good condition, including whether the indicator light is running normally, whether the task control function of the operation panel is complete, and carefully observe the appearance of the inverter in the operating state, and do the corresponding recording work; When repairing the inverter, check whether the voltage value and current value exceed the allowable ...

The difference between Schneider miniature circuit breaker and leakage switch The difference between Schneider miniature circuit breaker and leakage switch

1. Definition of miniature circuit breaker The electrical occupation is referred to as MCB, which is suitable for communicating 50/60Hz additional voltage 230/400V, additional current to 63A line overload and short circuit maintenance, and can also be used as infrequent operation conversion of the line under normal circumstances. ...

The difference between vector and general use of inverter - Schneider The difference between vector and general use of inverter - Schneider

1. The control accuracy of the vector type is higher than that of the general-purpose type. 2. The vector type has a large output torque at low speed, which can make the motor get a larger starting torque, which is suitable for application in the occasion of heavy load starting, such as: high-power long belt, hoist, etc. If used in some of the more common fields ...

Deterioration site and the principle of higher harmonic generation - Schneider Deterioration site and the principle of higher harmonic generation - Schneider

1. Electrical equipment will produce higher harmonics when it produces abnormality and deterioration, and the abnormality and deterioration of motors, loads, and inverters are used to distinguish the higher harmonics from 2 to 40 times, and the data is changed by FFT, and the analysis is made on the basis of the analysis data of long-term savings.

The inverter controls the speed of the AC motor – Schneider The inverter controls the speed of the AC motor – Schneider

Most of the motors used in the industry are of this type. The rotational speed of an induction AC motor (henceforth referred to as a motor) is approximately determined by the number of poles and frequency of the motor. The number of poles of the motor is fixed by the working principle of the motor. Since the pole ...

Schneider inverter ATV310 instruction with given Schneider inverter ATV310 instruction with given

The instructions of the inverter are given with the given conf→400- → 401 (given channel), → 01 (given analog terminal), 163 (given by remote display terminal), 164 (given by mudobus communication), 183 (navigation knob ...

How to prevent counterfeiting from Schneider switch sockets How to prevent counterfeiting from Schneider switch sockets

1. Logo The logo of the product is a status symbol, so it will be made very exquisitely. Schneider switches are also very careful in the production of logo, each letter is like an independent work of art, and let's see that the letter "A" is flat and wide. But the imitation ...

Schneider ATV312 inverter failure Schneider ATV312 inverter failure

1. OLF is motor overload. Possible reasons: 1. Triggered by high motor current. 2. The value of the [cold stator resistance] (rSC) parameter is wrong. Corrective measures: 1. Check the [Motor Thermal Current] (ItH) setting of the motor thermal maintenance function and check the motor load. Wait...

Two of Schneider's low-voltage power distribution products won the Germany Red Dot Award Two of Schneider's low-voltage power distribution products won the Germany Red Dot Award

Beijing, China, April 6, 2022 – Recently, the list of "Red Dot Planning Awards", known as one of the world's three cutting-edge industrial planning awards, was grandly announced in Germany.

Frequency converter and PLC connection problems - Schneider Frequency converter and PLC connection problems - Schneider

When the inverter is used to form an automatic control system for control, in many cases, the PLC and the inverter are used together, and how to correctly connect the PLC and the inverter together has become the key to the success of the system. 1.PLC switch ...

Schneider ATV32 inverter malfunction Schneider ATV32 inverter malfunction

1. The ATV32 inverter reports that the bLF is a brake control fault. Possible causes: 1. The brake release current is not reached. 2. When the braking logic control is assigned, only the closing frequency threshold [brake closure frequency] (bEn) is adjusted. Repair measures: 1. Check the inverter/electric ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top