Instrumentation mechanical equipment system - Schneider
1. Power system:
The wire and cable products selected in the power system mainly include overhead bare wires, busbars (busbars), power cables (plastic cables, oil-paper power cables (fundamentally replaced by plastic power cables), rubber cables, overhead insulated cables), branch cables (replacing part of the busbars), ...
|
|
The ultimate short-circuit breaking capacity of Schneider circuit breakers
The limit short-circuit breaking ability (ICU) refers to the short-circuit current that can be turned on and broken under certain experimental parameters (voltage, short-circuit current, power factor) and through a certain experimental procedure, and after this on-off, it will no longer continue to carry its rated current. It's experiments ...
|
|
Schneider UPS power supply preventive maintenance precautions
1 Contingency plan
Contingency plans are the top priority of preventive protection. Arrangements need to be better partnered with service providers to be part of the corporate programme. This means implementing processes and procedures for every type of thing, including contingency plans.
...
|
|
Schneider inverter enters the parameter setting method
1. The first step is to check whether the inverter is connected to the line, and whether the wiring of the control line and the power circuit is correct
2. Next, turn on the power of the inverter, enter the motor parameters, and perform motor identification
3. Next, set the function parameters to launch the ...
|
|
Schneider instrumentation maintenance precautions
1. Don't blindly knock and bump when overhauling to avoid expansion failures, and the more you repair, the worse it gets.
2. Do not plug and unplug various control boards and plugs with electricity. Due to the strong induced electromotive force generated by plugging and unplugging the control board under the power-on condition, the instantaneous ...
|
|
Schneider miniature circuit breaker problem analysis and answer
Fault 1: The shell of Schneider MCB product is yellowed or burned.
Reason 1: It is very likely that the magnetic coil inside the circuit breaker is burned out because of harmonics or high-frequency signals.
Method 1: * The good thing is that the filtering can be satisfied with the use of 50Hz/60Hz power frequency.
...
|
|
Schneider molded case and miniature circuit breaker recommended models
Molded case circuit breaker recommendation
Schneider EZD series
Create a high-quality circuit breaker for secondary power distribution
EZD molded case circuit breaker is a product series of molded case circuit breakers specially designed for secondary power distribution by Schneider Electric, which is especially suitable for ...
|
|
Schneider inverter ATV61 OPF failure analysis
Q: 250KW ATV61 with 250KW fan, when decelerating to low speed, OPF (motor missing three-phase) problem will be reported occasionally. There are no contactors or switches between the inverter and the motor.
Answer: This situation seems to be a problem with the inverter, which is a false alarm. Not really! The fan is decelerating ...
|
|
Precautions for external wiring of the inverter
In the process of connecting the line of the inverter, it is necessary to pay attention to the following aspects:
1. The power supply must be connected to the main circuit power terminal L1/R, L2/S, L3/T, if the power supply is connected to other terminals by mistake, the inverter will be damaged.
2. It is necessary for the grounding terminal to be well connected.
|
|
Selection and control of the inverter installation - Schneider
Frequency converters are widely used equipment in modern industry. If you want to complete the functions of soft stop, soft start, stepless speed regulation or special requirements for speed rise and fall, you need the more advanced speed control equipment in modern asynchronous motors - frequency converters. The main circuit of the equipment is selected to communicate - DC - communication ...
|
|
Schneider PLC failure steps
(1) If the signal is controlled on a counter, first look at the logic that controls the reset, then the counter signal. Follow steps 2 to 5 above.
(2) If Schneider PLC aborts in some places where the output is encouraged, generally in the middle of the situation, then look for the next step ...
|
|
Schneider intermediate relays
Schneider 24VDC intermediate relays are the most common components in control systems. Generally, 2 normally open and 2 normally closed are the most commonly used, but sometimes 4 normally open and 4 normally closed contacts are not enough. Both have different coil and base models.
...
|
|
Schneider circuit breaker maintenance method
1. Insist that the air is moist or unclean, and the pipes are not clean, which may have the following consequences:
(1) The wet gas is decomposed into mixed gases such as hydrogen and oxygen under the effect of arcing, destroying the insulation between the fractures after the main contact is broken, which is difficult to arc or arc re-ignition, and in severe cases, arc extinguishing will be formed.
|
|
Schneider relay model introduction
RM4 Series Control Relay (Three-phase Power Control)
RM4 series voltage steerable relays
RM4 current operated relay
RM4 level control relay
RM17 three-phase power controller
RM35 3-phase power control relay
RM17 Voltage Steerable Relay ...
|
|
Circuit breaker breaking capacity selection - Schneider
How to choose the circuit breaker break? Rated voltage and current are the key
For professional electrical operators, the question of how to choose the circuit breaker can be said to be easy and effortless, but it is a bit difficult for novices. Circuit breaker breaking can ...
|
|
Anti-electromagnetic interference method - Schneider
There are three main sources of electromagnetic disturbance to the industrial system: first, space field disturbance, which enters the system through electromagnetic wave radiation; the second is power disturbance, which directly damages the system; The third is the signal disturbance channel, which enters the system through the front and rear channels connected to the host. In order to ensure that the instrumentation ...
|
|
Schneider disconnector operation inspection content and requirements
(1) Whether the closing of the barrier switch is defective, whether there is no failure or dislocation;
(2) The porcelain insulation of the barrier switch should be free of cracks, discharge phenomena and flashover traces;
(3), contact viewing: a, view ...
|
|
Schneider instrumentation maintenance precautions
1. When installing and adjusting the appearance, the original status should be recorded for rehabilitation.
2. When repairing the appearance of fine instruments, if you accidentally bounce small parts away, you should first determine the direction where you can fly.
|
|
Inverter trip protection circuit – Schneider
After the maintenance function of the inverter is caused by the operation of the problem, it will trip immediately, and the fault code will be displayed together, and the tripping alarm indication circuit of the peripheral inverter will send out an audible and visual alarm to remind the operator to clean up the problem in time.
Inverter hopping ...
|
|
Schneider pushbutton switch type
(1) Protective button: a kind of button with a protective shell that can prevent the internal button parts from being mechanically damaged or people touching the live part, and its code is H.
(2) Dynamic break button: Under normal conditions, the switch contact is a kind of button that is turned on.
(3) Dynamic button: Under normal conditions, the ...
|