When the LS power generation module is put into operation, its working process is generally divided into three stages, namely input sampling, user program fulfillment and output rewriting. The completion of these three phases is called a scan cycle. Throughout the entire operation, the PLC's CPU repeats the above three phases at a certain scanning speed.
(1) Input sampling stage In the input sampling stage, the PLC reads all input conditions and data sequentially in a scanning manner, and stores them in the corresponding unit in the I/O image area. After the input sampling is complete, it moves to the user program fulfillment and output rewriting phase. In both phases, even if the input status and data change, the condition and data of the corresponding cells in the I/O map will not change. Therefore, if the input is a pulsed signal, the width of the pulse signal must be greater than one scan period to ensure that the input can be read in any case.
(ii) User program fulfillment phase
During the user program fulfillment phase, the LS power generation module always scans the user program in a top-down order (ladder diagram). When scanning each ladder diagram, the control circuit composed of each contact on the left side of the ladder diagram is always scanned first, and the control circuit composed of contacts is logically operated in the order of first left and then right, first up and then down, and then according to the results of logical operation, the corresponding position of the logic coil in the system RAM storage area is rewritten; Or override the position of the output coil in the I/O image area; Or confirm whether the special functional instructions specified in the ladder diagram are to be performed.
That is, in the process of user program performance, only the status and data of the input points in the I/O image area will not change, while the conditions and data of other output points and soft devices in the I/O image area or the system RAM storage area may change, and the ladder diagram ranked above, the program performance results will play a role in the ladder diagram of all the coils or data used in the below; Conversely, the condition or data of the overwritten logic coils in the ladder diagram below can only be used for the program above it until the next scan cycle.
In the process of program execution, if the immediate I/O command is used, the I/O point can be directly accessed. Even if the I/O command is used, the value of the input process image register will not be updated, and the program will take the value directly from the I/O module, and the output process image register will be updated immediately, which is somewhat different from the immediate input.
(iii) Output rewriting phase
When the user program is scanned, the LS power generation module enters the output rewriting stage. During this period, the CPU overrides all the output latch circuits according to the corresponding conditions and data in the I/O image area, and then drives the corresponding peripherals through the output circuits. At this time, it is the real output of the PLC.
|
More on that
|
How LS produces power PLC operation
Although many relays, timers and counters are often used in the ladder diagram programs used by LS PLC, LS PLC does not have these hardware physically, but uses memory and program programming methods to make logic control modifications, and connects external machines through output components.
|
|
Inverter installation environment requirements - LS power generation
Inverter device environmental requirements 1: operating temperature;
The inverter is a high-power electronic component, which is easily affected by the working temperature, and the product is generally required to be 0-55 °C, but in order to ensure that the work is [safe] [complete] [can be] [reliable], the use should be considered to leave room for control, and the control is at 40 ...
|
|
The basic method and steps of inverter debugging - power inverter
1. No-load energizing test of inverter
1. Ground the grounding terminal of the inverter.
2. Connect the power input terminal of the inverter to the power supply through the leakage maintenance switch.
3. Check whether the factory display window of the inverter is normal, if it is incorrect, it should be reset.
|
|
The power of LS power inverter is selected
The relationship curve between the load rate β and the power η of the inverter can be seen: when β = 50%, η = 94%; When β = 100%, η = 96%. Although the β has doubled, the η change is only 2%, but it is also considerable for medium to high power (a few hundred kilowatts to several thousand kilowatts) electric motors. The system power is equal to the inverter power ...
|
|
Meaning and classification of LS Electronic Motor Relay (EMPR).
The Electronic Motor Relay (EMPR) is a digital motor maintenance relay with an MCU that has a compact and compact form factor that can be combined directly with a contactor. Through the implementation of real-time data processing, high reliability and high precision can be completed, and it can pass through phase loss, reverse, unbalance, stalled rotor, connection...
|
|
Precautions for inverter installation and wiring - LS power generation
The inverter is an electric power control equipment that uses frequency conversion skills and microelectronic skills to control the AC motor by changing the power supply frequency of the motor operation. It is used in a wide range of fields, including conveyors, feeders, mixers, grinders, pulverizers, paper cutters, calenders in various industries...
|
|
What are the categories of PLC products?
The XGT series is a creative PLC product family that combines LS's power generation technology capabilities to provide next-generation solutions based on open networks, ultra-high-speed processing speeds, compact scales, and greatly improved software for the engineering environment. XGT series for a variety of ...
|
|
The selection principle of AC contactors - LS produces electricity
1. The voltage level of the AC contactor should be the same as the load, and the type of contactor should be suitable for the load.
2. The accounting current of the load should be less than or equal to the additional working current of the contactor.
The turn-on current of the contactor is greater than the starting current of the load, and the breaking current is greater than the load ...
|
|
The difference between servo drive and frequency converter - LS produces electricity
Servo drives and frequency converters are defined differently
The driver, also known as servo manipulator and servo amplifier, is a kind of manipulator used to control servo motors, and its function is similar to that of a frequency converter acting on a general communication motor. It is part of the servo system, mainly used for high-precision positioning ...
|
|
An integral part of an electrical solid state relay
Solid state relays consist of three parts: the input circuit, the barrier (coupling), and the output circuit.
Input Circuit:
According to the different categories of input voltage, the input circuit can be divided into DC input circuit, communication input circuit and AC-DC ...
|
|
Common practical knowledge in the inverter industry - power inverter
The inverter is the power frequency power supply (50Hz or 60Hz) converted into various frequencies of AC power supply to achieve the variable speed operation of the motor equipment, by changing the motor power frequency to achieve speed adjustment, is an ideal high-efficiency, high-speed regulation means. Frequency converters are used in industrial production and residential ...
|
|
LS power circuit breaker wiring method
The wiring method of the circuit breaker has the front of the board, the back of the board, the plug-in type, the drawer type, if the user has no special requirements, they are supplied according to the front of the board, and the wiring before the board is a common wiring method.
1. Wiring method behind the board: The wiring feature behind the board is that the circuit breaker can be replaced or repaired, without wiring from the beginning.
|
|
Classification of the nature of DC power supply of inverter - LS power generation
A frequency converter is actually an inverter. It starts by turning alternating current into direct current. Then the direct current is switched on and off with electronic components. Becomes alternating current. Thyristors for general inverters with larger power. And set up a device with adjustable frequency. Make the frequency adjustable within a certain range. Used to control ...
|
|
Electricity-producing permanent magnet AC contactor structure
The contactor is mainly composed of a drive system, a contact system, an arc extinguishing system and other parts.
1. Drive system: The drive system includes electronic modules, soft iron, and permanent magnets, which is an important part of the permanent magnet contactor.
|
|
Precautions for the use of inverter - LS produces electricity
1. The inverter should not be installed on the equipment with vibration, because the main circuit connection screw in the inverter is simply loose, and many inverters are damaged due to this reason.
Second, the wiring problem: the inverter input termination on an air initial maintenance current value can not be too large, ...
|
|
Analysis of the selection of major ventilator inverters - LS power generation
Now enterprises need to use a lot of ventilator inverters, the larger the scale of the enterprise, the more production workshops, the more ventilator inverters will be used. However, no matter how large the enterprise, there is a primary ventilator inverter, the selection of this kind of inverter is very important, because if there is no ...
|
|
Inverter external potentiometer connection method - LS power generation
The two wires are connected to the resistor, and the other wire is connected to the adjustment terminal.
The red thread is attached to the blackhead and inserted in a small hole.
Connect both ends of the IR potentiometer to +10V and ACM, and slide the termination to the voltage input terminal AVI.
...
|
|
The method of resetting the fault of the inverter
1. Power off the inverter and power it back on;
2. Press the FN button on BOP-2;
3. After the digital input 3, the default setting of 3 is reset to the problem;
4. Press the P button or power off, in the case of no problem;
...
|
|
An internal component of LS's power circuit breaker
1. Auxiliary contact: the contact mechanically linked with the main circuit of the circuit breaker and the closing mechanism is mainly used for the display of the circuit breaker and the closing status, and is connected to the control circuit of the circuit breaker through the opening and closing of the circuit breaker to control or interlock its related electrical appliances. For example, output to signal lights, relays, etc.
|
|
Parameter setting of LS power inverter
The inverter is a high-tech intelligent product, in order to let it complete the specified control mission, it must be set parameters, otherwise, it is like the computer is not installed and used, and it cannot be operated normally. The parameter setting is carried out by the control surface of the inverter. All kinds of inverters ...
|
|