What are the categories of PLC products?

Create Date: 2024-8-30 12:03:23|Source: LS/Power Generation

The XGT series is a creative PLC product family that combines LS's power generation technology capabilities to provide next-generation solutions based on open networks, ultra-high-speed processing speeds, compact scales, and greatly improved software for the engineering environment. In order to diversify the scope of application, the XGT series has a lineup of products ranging from small to small XGK-CPUS, which can be used for small and medium-sized planning and control, and XGK-CPUH, which is large enough to be capable of high-speed and large-capacity control.

                                 What are the categories of PLC products?

XG5000 program development, from debugging to warranty, can be a full set of corresponding automation software - programming software XG5000 - XGT PLC programming & debugging tools - maximize the retention of windows function, convenient operation - a variety of monitoring and diagnosis functions - one project, multi-function PLC, multi-task, multi-function program management - Operating environment: Windows2000, XP (Windows98, ME limited use).

The XGB Series is a next-generation PLC product group that integrates the most cutting-edge technology of LS Power Production, and in addition to compact size and powerful performance, it also greatly strengthens the network support function and achieves an innovative "futuristic total solution" with user-centered and consistent operation. LS Sanden provides customer-centric integrated automation solutions and presents the multi-functional XGB series of PLCs with high-reliability products that are available worldwide.

High-speed processing of operating parameters and data of XGT special modules - In the XGT CPU, the operation data of the special module is performed together with I/O - Replacement data of AD/DA modules, high-speed counting module, Interactive information such as instructions of the position module in this area, which enhances the convenience of use. - In the XG5000 parameter service, the parameters can be set through the special module parameter dialog - In the online service of the XG5000, through the special module monitoring dialog box, The operation data and intersection information of each module can be checked or tested. Maintenance Enhancement (Online Module Replacement) - If the power supply is not closed during the operation of the XGT CPU, the module can be replaced online by the special module
More on that
LS electric braking unit functions, advantages and operation process LS electric braking unit functions, advantages and operation process

First, the main function of the braking unit In some applications, the need for rapid speed reduction, according to the principle of asynchronous motor, it can be known that if the slip is larger, the greater the torque, the same braking torque will increase with the increase of the speed reduction rate, so that the system speed reduction time is greatly shortened, and the energy feedback is greatly ...

Three-phase motor current is too high - LS power generation Three-phase motor current is too high - LS power generation

First, the power supply problem 1. The power supply voltage is too high When the power supply voltage is too high, the motor back electromotive force, magnetic flux and magnetic flux density all increase. Since the magnitude of the iron loss is proportional to the square of the magnetic flux density, the iron loss increases, resulting in overheating of the core. And the increase in magnetic flux causes ...

Analysis of the problem of excessive current of LS three-phase motor for power generation Analysis of the problem of excessive current of LS three-phase motor for power generation

First, the power supply problem 1. The power supply voltage is too high When the power supply voltage is too high, the motor back electromotive force, magnetic flux and magnetic flux density all increase. Since the magnitude of the iron loss is proportional to the square of the magnetic flux density, the iron loss increases, resulting in overheating of the core. And the increase in magnetic flux causes ...

The reason for the overload trip of the inverter - LS generates electricity The reason for the overload trip of the inverter - LS generates electricity

1. The load is too heavy, the load carried by the motor is too heavy, or in other words, the resistance torque of the production machinery exceeds the additional torque of the motor. 2. Use improper overload, for example, increase the operating frequency of the inverter to the extra frequency of the motor, and the motor is in the extra frequency.

LS Electric has been selected as one of the "Top 100 Global Innovators" for 10 consecutive years. LS Electric has been selected as one of the "Top 100 Global Innovators" for 10 consecutive years.

In Clarivate's recent statement, LS Electric was named one of the top 100 innovators in the world. The trophy handover ceremony was held in Anyang, LS Electric R&D Park, with Kim Yeong-geun, Chief Technical Officer of LS Electric, and Ahn Seong-sik, CEO of Clarivate Korea, acting as representatives of both parties.

A common fatal form of failure of the terminal block - LS power generation A common fatal form of failure of the terminal block - LS power generation

1. Poor touch The metal conductor inside the terminal block is the core part of the terminal, which transmits the voltage, current or signal from the external wire or cable to the touch piece corresponding to the connector it matches. Therefore, it is necessary for the touch parts to have excellent structure, stable and reliable touch firmness.

Debugging of basic parameters of inverter - LS power generation Debugging of basic parameters of inverter - LS power generation

There are many functional parameters of the inverter, and there are generally dozens or even hundreds of parameters for users to choose. In practice, it is not necessary to set and debug every parameter, and most of them only need to use the factory setting value. However, some parameters are very closely related to the application of practice, and some of them are still ...

The touch screen controls the inverter steps The touch screen controls the inverter steps

1. The touch screen is controlled by PLC inverter 1. At present, the general control of the inverter needs to use PLC to communicate with the inverter, read the information of the inverter, and then the touch screen communicates with the PLC in order to complete the control of the inverter to start, stop, and monitor the operation of the inverter.

Inverter life extension method - LS power generation Inverter life extension method - LS power generation

1. The inverter should not be installed on the equipment with a sensation, because the main circuit connection screw in the inverter is easy to loosen, and many inverters are damaged due to this reason. 2. Wiring problem: the input terminal of the inverter should be connected to a ...

Inverter fault handling - LS power generation Inverter fault handling - LS power generation

1. The working temperature of the inverter is high 1. Check whether the ambient temperature of the inverter is too high; 2. Check whether the cooling fan inside the device is working normally; 3. Check whether the ventilation pores and mask grilles are blocked; 4. Check if the load is too heavy. ...

LS Electric helps Cisco Smart City build an industry benchmark LS Electric helps Cisco Smart City build an industry benchmark

In March 2019, LS Group signed a strategic cooperation agreement with Country Garden to build Cisco Smart City into an innovative model for smart cities. LS Electric will provide power distribution system solutions for Cisco (Guangzhou) Smart City, providing frame circuit breakers, molded case circuit breakers, vacuum circuit breakers, miniature circuit breakers, and micro circuit breakers.

An integral part of an electrical solid state relay An integral part of an electrical solid state relay

Solid state relays consist of three parts: the input circuit, the barrier (coupling), and the output circuit. Input Circuit: According to the different categories of input voltage, the input circuit can be divided into DC input circuit, communication input circuit and AC-DC ...

Summer maintenance and maintenance of inverter method - LS power generation Summer maintenance and maintenance of inverter method - LS power generation

1. Check the running status of the inverter, whether the voltage and current value during operation are within the normal range. 2. Carefully monitor and record the ambient temperature of the frequency conversion chamber, which is generally between -5 °C and 40 °C. The temperature rise of the phase-shifting transformer should not exceed 130°C. 3. Prevent ...

Analysis of heat dissipation problems of inverter - LS power generation Analysis of heat dissipation problems of inverter - LS power generation

In order to use the inverter correctly, it is necessary to consider that the service life of the VFD decreases exponentially with the increase in temperature. This is due to: When the ambient temperature rises by 10 degrees, the service life of the VFD is halved. So pay attention to heat dissipation! When the VFD is working, the current flowing through the VFD is very large, and the VFD emits ...

Wiring of the main circuit of the inverter - LS generates electricity Wiring of the main circuit of the inverter - LS generates electricity

1. The power supply should be connected to the R, S, and T terminals at the input end of the inverter, and must not be connected to the output terminal (U, V, W) of the inverter, otherwise the inverter will be damaged. After wiring, it is necessary to clean the trivial wires, which may cause abnormalities, failures and problems, and it is necessary to always keep ...

The application of the inverter to supply power to the motor has encountered a problem The application of the inverter to supply power to the motor has encountered a problem

A frequency converter is a device that converts power to other frequencies of power supply. The power frequency of our country is 50Hz, in the field of motors, in order to change the speed of the motor, or other performance changes, many motors choose inverter power supply. ...

The protection measures of the power generator inverter for the motor The protection measures of the power generator inverter for the motor

The protection of the motor by the power converter mainly includes the following aspects: overvoltage protection, undervoltage protection, overcurrent protection, phase loss protection, inverter protection, overload protection, grounding protection, short circuit protection, overfrequency protection and stall protection. ...

Methods for extending the service life of inverters - LS generates electricity Methods for extending the service life of inverters - LS generates electricity

1. The influence of electromagnetic disturbance on the inverter: In the modern industrial control system, the microcomputer or PLC control technology is mostly selected, and in the process of system planning or transformation, it is necessary to pay attention to the disturbance of the inverter to the microcomputer control board. The inverter is disturbed by the outside world, because the user ...

Characteristics of single-phase current converter - LS power generation Characteristics of single-phase current converter - LS power generation

Single-phase current transmitter is a kind of power test substation developed for the power measurement of single-phase AC in motor test on the basis of motor test and test technology research, in accordance with IEC and relevant national specifications for motor test. The selection of advanced filtering technology, reasonable software algorithms, processing ...

Failure analysis of electromagnetic system of LS power production contactor Failure analysis of electromagnetic system of LS power production contactor

(1) The core noise is large: it is normal for the electromagnetic system to produce a slight humming sound during operation, if the sound is too loud or abnormal, it can be judged that the electromagnetic system has a problem, and there are three reasons: (1) Poor contact between the armature and the core or tilting of the armature. After repeated collisions between the touch of the armature and the core, ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top