Inverter installation environment requirements - LS power generation

Create Date: 2024-8-30 12:03:23|Source: LS/Power Generation

Inverter device environmental requirements 1: operating temperature;

The inverter is a high-power electronic component, which is very easy to be affected by the working temperature, and the product is generally required to be 0-55 °C, but in order to ensure that the work is [safe] [complete] [can be] [reliable], the use should be considered to leave room for control, and the control is below 40 °C. In the control box, the inverter should generally be installed in the upper part of the box, and strictly abide by the device requirements in the product manual, and it is not allowed to put the heating element or the component that is easy to heat up close to the bottom of the inverter.

                            Inverter installation environment requirements - LS power generation

Inverter device environmental requirements 2: ambient temperature;

When the temperature is too high and the temperature changes greatly, the inverter is prone to condensation, and its insulation function will be greatly reduced, and it may even cause a short circuit. If necessary, add desiccant and heater to the box. In the water treatment room, water vapor is generally heavier, and this problem will be more prominent if the temperature changes significantly.

Inverter device environmental requirements three: corrosive gas;

If the concentration of corrosive gas is high in the application environment, it will not corrode the leads and printed circuit boards of the components, and it will also accelerate the aging of plastic equipment and reduce the insulation function.

Inverter device environmental requirements four: oscillation and impact;

When a control cabinet equipped with a frequency converter is subjected to mechanical oscillations and shocks, it can cause poor electrical contact. Huai'an Thermal Power presents such a problem. At this time, in addition to improving the mechanical strength of the control cabinet and keeping away from the oscillation source and impact source, the anti-seismic rubber pad should also be used to fix the electromagnetic switches outside and inside the control cabinet and other components that produce oscillation. After the device has been running for a while, it should be inspected and protected.

Inverter device environmental requirement five: electromagnetic wave disturbance;

Due to the rectification and frequency conversion in the work of the inverter, a lot of disturbing electromagnetic waves are generated around, and these high-frequency electromagnetic waves have a certain disturbance to the nearby appearance and instruments. Therefore, the internal and external surfaces and electronic [systems] of the cabinet should be made of metal shells to shield the disturbance of the inverter from the external appearance. In addition, the connection between the electrical components, instruments and the surface should be shielded control cables, and the shielding layer should be grounded. If the electromagnetic disturbance is not handled well, the entire [system] [system] will often be unable to work, resulting in the failure or damage of the control unit.

More on that
LS power circuit breaker wiring method LS power circuit breaker wiring method

The wiring method of the circuit breaker has the front of the board, the back of the board, the plug-in type, the drawer type, if the user has no special requirements, they are supplied according to the front of the board, and the wiring before the board is a common wiring method. 1. Wiring method behind the board: The wiring feature behind the board is that the circuit breaker can be replaced or repaired, without wiring from the beginning.

Selection of the color of the conductor of the high and low voltage switchgear - LS power production Selection of the color of the conductor of the high and low voltage switchgear - LS power production

1 AC three-phase circuit a) Yellow for phase A, green for phase B, and red for phase C; b) Light and blue colors for the neutral line or neutral line; C) Yellow and green two-color wires are used for safety grounding wires. 2 AC circuits connected by twinax wires or stranded wires: red, black ...

Relationship between motion control and frequency converter Relationship between motion control and frequency converter

Motion control has a significant period characteristic, it is a combination of a variety of high-tech to push industrial automation, office automation and home automation to a higher stage. At present, the motion control is mainly composed of three parts: inverter, motor and controller. ...

Introduction of LS power products Introduction of LS power products

1. Power-related products: medium, low and high voltage electrical products; (1) Low Voltage Products: Molded Case Circuit Breaker, Air Circuit Breaker, LS Contactor & Overload Relay, Miniature Circuit Breaker, Dual Power Automatic Transfer Switch, Intelligent Motor Protector, Manual Motor Starter, Surge Protection ...

The given way of the inverter - LS generates electricity The given way of the inverter - LS generates electricity

Frequency given meaning and given method The speed of the motor can be changed by changing the output frequency of the inverter. In order to adjust the output frequency of the inverter, the inverter must supply the signal of the changed frequency, which is called the frequency given signal.

Inverter overvoltage alarm analysis - LS power generation Inverter overvoltage alarm analysis - LS power generation

Change the shutdown mode to inertia parking and you're done! In this way, after the fan is stopped, the inverter will immediately turn off the output, so that the fan can stop freely, at this time, although the fan is in the power generation situation, but the electricity generated by the fan will not pass through the inverter of the inverter to generate direct current, so the inverter will not overvoltage ...

Introduction of plc inverter - LS power generation Introduction of plc inverter - LS power generation

Because the imported products of the inverter brand have their own PLC function, they mainly play an important role in the control effect of mechanical equipment, and play an important role in the equipment, which can regulate the operation and control of the machine and meet the requirements of users. It should be scale pLC ...

LS power production automation subdivision industry service era LS power production automation subdivision industry service era

LS power automation drives are mainly for industrial enterprises and construction enterprises, including municipal, metallurgical, electric power, chemical and other power-oriented industrial enterprises, car, food and beverage, pharmaceutical and other professional enterprises, as well as OEM equipment manufacturing enterprises. ...

Fault analysis of servo motors – LS power generation Fault analysis of servo motors – LS power generation

1. Problem phenomenon: servo error OL, servo motor can not start, and there is abnormal sound problem analysis and possible causes: (1) Bearing damage, foreign objects falling and stuck, stator magnet bursting and falling or moving tissue jamming caused by the motor itself. (2) ...

The difference between LS power inverter and servo The difference between LS power inverter and servo

An important difference between servo and frequency conversion is that frequency conversion can be without encoder, while servo must have an encoder for electronic commutation. 1. What the two have in common: The AC servo technology itself is to learn and apply the technology of frequency conversion, and the servo control of the DC motor is based on the ...

The torque of the inverter is directly used as the controlled quantity mode - LS generates electricity The torque of the inverter is directly used as the controlled quantity mode - LS generates electricity

VVVF frequency conversion, vector control frequency conversion, and direct torque control frequency conversion are all one of the AC-DC-AC frequency conversion. Its common disadvantages are low input power factor, large harmonic current, large demand for energy storage capacitors in DC circuits, and renewable energy can not be reflected back to the grid, that is, it cannot carry out four-quadrant operation.

Introduction of LS PLC programming software Introduction of LS PLC programming software

LS PLC programming software is a professional PLC programming assistant tool, providing excellent interface, which can carry out PLC programming operations such as online modification, debugging and self-diagnosis, packing and debugging, etc., compatible with LG Master-K series and LG MASTER-K series, which can make you in the process of processing in a timely manner.

Inverter air boost test step - LS power generation Inverter air boost test step - LS power generation

1. Download the control program. 2. Put the inverter in open-loop experimental mode and set the appropriate parameters. 3. Connect the incoming cable of the inverter. The cable on the output side of the inverter is not connected. 4. Push the high-voltage cabinet to the experimental position, close the switch, and ...

LS Electric has been selected as one of the "Top 100 Global Innovators" for 10 consecutive years. LS Electric has been selected as one of the "Top 100 Global Innovators" for 10 consecutive years.

In Clarivate's recent statement, LS Electric was named one of the top 100 innovators in the world. The trophy handover ceremony was held in Anyang, LS Electric R&D Park, with Kim Yeong-geun, Chief Technical Officer of LS Electric, and Ahn Seong-sik, CEO of Clarivate Korea, acting as representatives of both parties.

The selection principle of AC contactors - LS produces electricity The selection principle of AC contactors - LS produces electricity

1. The voltage level of the AC contactor should be the same as the load, and the type of contactor should be suitable for the load. 2. The accounting current of the load should be less than or equal to the additional working current of the contactor. The turn-on current of the contactor is greater than the starting current of the load, and the breaking current is greater than the load ...

The cause of motor burnout caused by the inverter - electricity production The cause of motor burnout caused by the inverter - electricity production

In fact, the fault of the motor is not the cause of the motor itself, most of them are caused by the non-standard debugging of the inverter or the wrong inverter motor when the inverter motor is used, etc., mainly in the following situations: 1. Treat the general motor as a ...

The Importance of Welding in Inverter Maintenance – LS Generates Electricity The Importance of Welding in Inverter Maintenance – LS Generates Electricity

Whether the welding skills of the inverter repair personnel are excellent is directly related to the quality and results after repair. If the welding quality is not up to standard during repair, the pins of the components will be broken when the components are disassembled, the printed circuits on the PCB will be damaged, the components will not be soldered firmly when the components are installed, and the two components ...

Briefly describe LS ABE203b molded case circuit breaker Briefly describe LS ABE203b molded case circuit breaker

The circuit breaker is a fundamental low-voltage electrical appliance, which has the function of overload, short circuit and undervoltage maintenance, and has the ability to maintain the line and power supply. Circuit breaker is an indispensable product in electrical safety. Due to different applications, there are molded case circuit breakers, frame circuit breakers, miniature circuit breakers, etc.

Inverter overvoltage fault analysis method - LS power generation Inverter overvoltage fault analysis method - LS power generation

The overvoltage of the inverter is manifested in the tributary voltage of the DC bus. Under normal conditions, the direct current of the inverter is the average value of the three-phase full-wave rectification. If calculated by 380V line voltage, the average DC voltage Ud=1.35U line=513V.

The cause of the failure of low-voltage electrical appliances - LS power generation The cause of the failure of low-voltage electrical appliances - LS power generation

In the control circuit of low-voltage electrical appliances, there are simple low-voltage components such as: buttons, safe, etc.; There are also slightly messy low-voltage electrical control components, such as circuit breakers, touch devices, time relays, thermal relays and other simple components, which makes it necessary to diagnose and analyze the cause of the problem. ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383