An internal component of LS's power circuit breaker

Create Date: 2024-8-30 12:03:23|Source: LS/Power Generation

1. Auxiliary contact: the contact mechanically linked with the main circuit of the circuit breaker and the closing mechanism is mainly used for the display of the circuit breaker and the closing status, and is connected to the control circuit of the circuit breaker through the opening and closing of the circuit breaker to control or interlock its related electrical appliances. For example, it outputs signals to traffic lights, relays, etc. The additional current of 100A for the shell frame level of the molded case circuit breaker is a single break conversion contact, and 225A and above is a bridge contact structure, and the heating current is 3A; The additional current of 400A and above in the shell frame level can be installed with two normally open and two normally closed, and the heating current is 6A. The number of operation functions is the same as the total number of operation functions of the circuit breaker.

                               An internal component of LS's power circuit breaker

2. Alarm contact: the alarm contact used for circuit breaker accidents, and this contact only acts when the circuit breaker trips and breaks, mainly used for the load of the circuit breaker to overload, short circuit or undervoltage and other faults and trips freely, the alarm contact is converted from the original normally open orientation to the closed position, and the indicator light or electric bell and buzzer in the auxiliary line are turned on to show or remind the circuit breaker of the fault tripping status. Because the probability of the circuit breaker tripping freely due to load failure is not too much, the life of the alarm contact is 1/10 of the life of the circuit breaker. The operating current of the alarm contact generally does not exceed 1A.

3. Shunt excitation tripper: Shunt tripper is a kind of tripper encouraged by a voltage source, and its voltage has nothing to do with the main circuit voltage. The shunt trip is an accessory for long-distance operation and opening. When the supply voltage is equal to any voltage between 70% and 110% of the additional control supply voltage, the circuit breaker can be reliably disconnected. The shunt tripper is a short-term operation system, and the coil energizing time generally cannot exceed 1S, otherwise the wire will be incinerated. In order to avoid coil incineration, the molded case circuit breaker is connected in series with a micro switch in the shunt trip coil, when the shunt tripper is engaged by the armature, the micro switch is converted from normally closed to normally open, because the control line of the power supply of the shunt tripper is blocked, even if the button is held down artificially, the shunt coil will not be energized again, which avoids the occurrence of coil burning. When the circuit breaker is re-closed, the micro switch is back in the normally closed position.

4. Under-voltage tripper: The under-voltage tripper is a kind of tripper that makes the circuit breaker have a delay or no delay when its terminal voltage drops to a specified range, and when the power supply voltage drops (or even slowly drops) to the range of 70% to 35% of the additional operating voltage, the under-voltage tripper should operate, and the under-voltage tripper should be able to avoid the circuit breaker closing when the power supply voltage is equal to 35% of the additional operating voltage of the tripper; When the supply voltage is equal to or greater than 85% of the additional operating voltage of the undervoltage tripper, the circuit breaker should be able to be securely closed under hot conditions. Therefore, when the power supply voltage in the protected circuit produces a certain voltage drop, the circuit breaker can be automatically disconnected to block the power supply, so that the load electrical appliances or electrical equipment below the circuit breaker are protected from damage by the undervoltage. When in use, the under-voltage tripper coil is connected to the power supply side of the circuit breaker, and the circuit breaker is closed only after the under-voltage tripper is energized.

More on that
A brief description of the K120S series plc A brief description of the K120S series plc

K120S series PLC product is a unit PLC product introduced to the market by LS in 2004, which has laid a solid foundation in the low-end small machinery supporting industry with its high-performance price ratio. Relying on some special functions of the product, it has also won some industry praise. ...

The wiring distance between the motor and the inverter The wiring distance between the motor and the inverter

Burn two new motors in a row! The output current and voltage of the inverter are balanced, the input voltage is balanced, the current is unstable, and the fluctuation is 20%-50%, the inverter is burned off by a short circuit between 35Hz turns, the grid voltage is very stable, 720V, the interval between the motor and the inverter is 120m, and the input and output terminals of the inverter are powered ...

Parameter setting of LS power inverter Parameter setting of LS power inverter

The inverter is a high-tech intelligent product, in order to let it complete the specified control mission, it must be set parameters, otherwise, it is like the computer is not installed and used, and it cannot be operated normally. The parameter setting is carried out by the control surface of the inverter. All kinds of inverters ...

The difference between inverter overload and overcurrent - LS generates electricity The difference between inverter overload and overcurrent - LS generates electricity

Inverter is an important drive material in modern industrial production, as a power equipment, it is working hard all the time, so its fault rate is very high, and the rapid processing of inverter faults, to ensure the continuity of industrial production, is every maintenance electrician and on-site debugging of electricians.

An integral part of an electrical solid state relay An integral part of an electrical solid state relay

Solid state relays consist of three parts: the input circuit, the barrier (coupling), and the output circuit. Input Circuit: According to the different categories of input voltage, the input circuit can be divided into DC input circuit, communication input circuit and AC-DC ...

The cause of the failure of low-voltage electrical appliances - LS power generation The cause of the failure of low-voltage electrical appliances - LS power generation

In the control circuit of low-voltage electrical appliances, there are simple low-voltage components such as: buttons, safe, etc.; There are also slightly messy low-voltage electrical control components, such as circuit breakers, touch devices, time relays, thermal relays and other simple components, which makes it necessary to diagnose and analyze the cause of the problem. ...

The size of the contactor is selected by the type of contactor - LS produces electricity The size of the contactor is selected by the type of contactor - LS produces electricity

1. Select the corresponding category of contactor according to the control object, operation times and application category of the contactor. 2. Select according to the rated voltage of the line at the application location. 3. Select the rated current of the main contact of the contactor according to the load capacity. 4. About the voltage level of the lead coil ...

LS power generation low-voltage universal inverter vector control mode LS power generation low-voltage universal inverter vector control mode

The method of vector control frequency conversion speed regulation is to change the stator current Ia, Ib, Ic of the asynchronous motor in the three-phase coordinate system, after the three-phase - two-phase change, equivalent to the communication current Ia1Ib1 under the two-phase static coordinate system, and then after the directional rotation according to the rotor magnetic field, it is equivalent to synchronous rotation sitting.

The power frequency motor is abnormally installed with an inverter - LS produces electricity The power frequency motor is abnormally installed with an inverter - LS produces electricity

Installing a variable-frequency drive (VFD) on the power frequency motor can complete the accurate control and speed regulation of the motor, and improve the power and accuracy of the forward motor. However, if not properly equipped and used, it may cause the following hazards: ​ ...

LS takes you to understand the inverter in the inverter LS takes you to understand the inverter in the inverter

Contrary to the rectifier, the inverter converts the DC power into the communication power of the required frequency, and the 3-phase communication output can be obtained by turning on and off the 6 switching devices at the confirmed time. Take a voltage-type PWM inverter as an example to show the switching time and voltage waveform. Control circuit ...

LG Inverter-LS Inverter-IGXA Sales LG Inverter-LS Inverter-IGXA Sales

LG Inverter LS Inverter IGXA Series ** for sale, its models are as follows: SV004IGXA-4 60210101W0 Power 0.37KW (Input: 3-phase 380V / Output: 3-phase 0——380V)   SV008IGXA-4 6021010 ...

Servo drives and servo motors – LS produces electricity Servo drives and servo motors – LS produces electricity

Driver: Under the premise of carrying out frequency conversion skills, the servo drive has carried out more advanced control skills and algorithm operations than general frequency conversion in the current ring, speed ring and azimuth ring inside the drive (the frequency converter does not have this ring), and it is much stronger than the traditional servo in terms of function.

Precautions for powering on the inverter after the LS power production holiday Precautions for powering on the inverter after the LS power production holiday

1. During the holiday, low temperature can easily cause the equipment to be damp, check whether the electrical equipment is dry, whether there is moisture and condensation; 2. Check whether the grounding wire is loose and whether the cable is damaged by rodents and insects; 3. Sort out the dust and oil stains, and inverter ...

Grounding of the secondary side of the voltage transformer and the current transformer - power generation Grounding of the secondary side of the voltage transformer and the current transformer - power generation

1. The transformer is grounded twice It refers to the grounding of the S2 terminal of the current transformer or the ground of the n terminal of the voltage transformer. As long as the single point is grounded, because the transformer is blocked between the second and the first, before grounding, the secondary winding has no potential connection with the ground, after grounding, the transformer ...

Contactors play a role in industrial electricity Contactors play a role in industrial electricity

The contactor is an automatic switch for industrial roofs to control its on/off with a button. The contactor consists of an electromagnetic coil, a static armature, a moving armature, a static contact, a moving contact and a fixing bracket. The principle is that when the electromagnetic coil of the contactor is connected to the communication electricity, a strong magnetic field will be generated to make the center of the coil ...

Why can't the inverter be equipped with a leakage protector - power generation Why can't the inverter be equipped with a leakage protector - power generation

When using an inverter, a leakage maintainer must not be used. This is a major principle of the use of frequency converters. Some users choose the corresponding leakage maintainer for the inverter when using the inverter. *The result is: the inverter moves together ...

LS automatic gain adjustment for power generation LS automatic gain adjustment for power generation

In fact, there are also options for automatic gain adjustment, which generally divide the control response into several levels, such as high echo, medium echo, and low echo, which can be set by the user according to actual needs. Azimuth Share Buff: 1. Set the share gain of the azimuth ring adjuster; 2 ...

Models and features of LS Metasol series products Models and features of LS Metasol series products

Metasol series MS (100A and below) products are newly launched and the primary product specifications: contactors, thermal relays, and center relays. Features: The body is small, the internal structure is sealed, and the safety factor is high ...

Why can't the inverter be equipped with a leakage protector? Why can't the inverter be equipped with a leakage protector?

When using an inverter, a leakage maintainer must not be used. This is a major criterion for the use of frequency converters. Some users choose the corresponding leakage maintainer for the inverter when using the inverter. *The result is: the inverter moves together ...

Brake unit, brake resistor function - LS generates electricity Brake unit, brake resistor function - LS generates electricity

Brake unit: The function of the braking unit is to turn on the energy-dissipating circuit when the voltage Ud of the DC circuit exceeds the specified limit (such as 660V or 710V), so that the DC circuit can release energy by thermal energy after passing through the braking resistor. The braking unit can be divided into built-in and external, the former is ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top