Now enterprises need to use a lot of ventilator inverters, the larger the scale of the enterprise, the more production workshops, the more ventilator inverters will be used. However, no matter how large the enterprise, there is a primary ventilator inverter, the selection of this kind of inverter is very important, because if the selection is not correct, it may cause huge losses to the enterprise. So how should this inverter be acquired:
Choose the right inverter for your company's power
Before the acquisition of the primary ventilator inverter, we must have a comprehensive understanding of the enterprise, understand how much the inverter power is required in the current production process of the enterprise, for example, the enterprise needs to use 200KW ventilator inverter, then the acquisition of 200KW-300KW ventilator inverter can, the purchase of too large power ventilator inverter is a waste, the purchase of too small power ventilator inverter can not meet the production needs of the enterprise.
Select the functions that meet the needs of the market
Now the market competition is becoming more and more severe, and the selection of this kind of inverter must meet the market demand. Although there is no need to buy advanced fan drives, it is not possible to buy fan drives that have been obsolete by age. This is an era of fierce competition, and if the equipment has fallen behind, it is difficult to make a living in this market.
Find out how long your equipment will last
The acquisition of the primary ventilator inverter must understand the service life, because if the equipment has frequent problems, the company's work efficiency will decrease, and the profit will also decline.
To sum up, when you buy the primary ventilator inverter, you need to analyze the service life, function, and power from three aspects, so as not to buy the wrong equipment.
|
More on that
|
The main part of LS power inverter is composed
The inverter circuit is the first part of the inverter
The function of the DC central circuit is to smooth the output of the rectifier circuit to ensure that the inverter circuit and the control power supply can obtain a DC power supply with higher quality. When the rectifier circuit is the voltage flow of the central circuit, the primary component is the electrolysis of Darongtong ...
|
|
What are the advantages of frequency conversion speed regulation - LS power production
1. Outstanding frequency conversion speed regulation characteristics
Completing the frequency conversion speed regulation of asynchronous motor is the "century wish" that people have been waiting for since the creation of asynchronous motor for 100 years. Through unremitting improvement, enhancement and perfection, the speed regulation function of VFD is not bad, that is, compared with the DC speed regulation system, the part ...
|
|
Grounding of the secondary side of the voltage transformer and the current transformer - power generation
1. The transformer is grounded twice
It refers to the grounding of the S2 terminal of the current transformer or the ground of the n terminal of the voltage transformer. As long as the single point is grounded, because the transformer is blocked between the second and the first, before grounding, the secondary winding has no potential connection with the ground, after grounding, the transformer ...
|
|
An integral part of an electrical solid state relay
Solid state relays consist of three parts: the input circuit, the barrier (coupling), and the output circuit.
Input Circuit:
According to the different categories of input voltage, the input circuit can be divided into DC input circuit, communication input circuit and AC-DC ...
|
|
The basic component of the inverter is LS power generation
The inverter is usually divided into 4 parts: the rectifier unit, the high-capacity capacitor, the inverter and the controller.
Rectifier unit: converts alternating current with a fixed operating frequency into direct current.
High Capacitance: Stores converted electrical energy.
...
|
|
Introduction of LS electric power contactors
How LS Contactor Works:
Generally, after the contactor coil is energized, the entire coil current will generate a magnetic field, which will make the core inside have electromagnetic attraction to attract the core, and let their communication contactor point action normally closed contact disconnect, or close, which ...
|
|
Precautions for powering on the inverter after the LS power production holiday
1. During the holiday, low temperature can easily cause the equipment to be damp, check whether the electrical equipment is dry, whether there is moisture and condensation;
2. Check whether the grounding wire is loose and whether the cable is damaged by rodents and insects;
3. Sort out the dust and oil stains, and inverter ...
|
|
Features of LS SUSOL series circuit breakers
Features of SUSOL series circuit breakers:
It can be used as the main switch of electrical equipment, and the limit breaking ability is high, Icu=Ics
Modular construction of circuit breakers: Tripper replacement (TS series) can be combined in a variety of combinations, such as ...
|
|
The role of contactors in industrial electricity - LS generates electricity
The contactor is an automatic switch in industrial electricity that uses a button to control its on/off. The contactor consists of an electromagnetic coil, a static armature, a moving armature, a static contact, a moving contact and a fixing bracket. The principle is that when the electromagnetic coil of the contactor is connected to the communication electricity, a strong magnetic field will be generated to make the center of the coil ...
|
|
The wiring distance between the motor and the inverter
Burn two new motors in a row! The output current and voltage of the inverter are balanced, the input voltage is balanced, the current is unstable, and the fluctuation is 20%-50%, the inverter is burned off by a short circuit between 35Hz turns, the grid voltage is very stable, 720V, the interval between the motor and the inverter is 120m, and the input and output terminals of the inverter are powered ...
|
|
The difference between voltage inverter and current inverter - LS produces electricity
For example, the operating principle of voltage inverter is mainly to regulate the voltage source, and the voltage source regulates the current to achieve the role of conditioning, while the current inverter is to directly regulate the current to achieve the role of conditioning.
...
|
|
The application of LS inverter in the grinding machine industry
First, the process requirements of the grinding machine:
The grinding machine is a kind of textile machinery, and its function is to polish the dyed cloth to improve its added value, which is an important process in the printing and dyeing process. The traditional drive mode is driven by a DC motor, which is linked with the lifting rod ...
|
|
The protection measures of the power generator inverter for the motor
The protection of the motor by the power converter mainly includes the following aspects: overvoltage protection, undervoltage protection, overcurrent protection, phase loss protection, inverter protection, overload protection, grounding protection, short circuit protection, overfrequency protection and stall protection.
...
|
|
LS has reached agreements with Doosan and Hanwha in Korea on a business model for vacuum power generation
LS Electric recently signed an MOU agreement with Doosan Fuel Cell, Hanwha Power Systems, and Hanwha Asset Management in Seoul, Korea, to establish a business partnership for city gas companies to develop a fuel cell-vacuum power generation business model. Through this agreement, the two sides will expand the scope of cooperation ...
|
|
The function and function of the inverter VFD - LS produces electricity
1. Energy saving
The energy-saving effect of VFD is mainly manifested in the application of fans and water pumps. After the fan and pump load is selected for frequency conversion speed regulation, the power saving rate is 20% - 60%, because the actual power consumption of the fan and pump load is basically proportional to the cubic speed. When users ask for an average ...
|
|
The production power takes you to read the PLC ladder diagram
1. Trapezoidal stairs start from the horizontal line and end up with a vertical line (generally you can omit not to draw, only draw the left busbar). On the left side of each row is the junction combination, indicating the conditions that drive the logic coil, while the logic coil indicating the effect can only be connected to the bus on the right. The contact can not appear in the coil right ...
|
|
The method of judging the quality of components - LS power production
1. Detection of ordinary diodes
Use the MF47 multimeter to measure, connect the red and black watch pens to the two ends of the diode, read the reading, and then adjust the watch pen to measure. According to the results of two measurements, the forward resistance value of the general low-power germanium diode is 300-500Ω, and the silicon diode ...
|
|
Quickly locate switching power supply faults
Switch Mode Power Supply (SMPS) will cause the base of the switch tube to fail to get the switching pulse and intermittently operate due to the short circuit of the load, the failure of the self-vibration circuit and the loss of control of the protection circuit, which makes it difficult to locate the shortcomings of SMPS. Difficult to repair the work ...
|
|
Analysis of common faults of LS AC contactors
AC contactor is generally used to turn on or off the power supply in the control circuit of electromechanical equipment, it can frequently turn on or off the AC circuit, and can realize long-distance control.
The toucher is mainly composed of a contact system and an electromagnetic system, and the problem of AC contactor is generally generated in the coil.
|
|
The power of LS power inverter is selected
The relationship curve between the load rate β and the power η of the inverter can be seen: when β = 50%, η = 94%; When β = 100%, η = 96%. Although the β has doubled, the η change is only 2%, but it is also considerable for medium to high power (a few hundred kilowatts to several thousand kilowatts) electric motors. The system power is equal to the inverter power ...
|
|