The inverter is a high-tech intelligent product, in order to let it complete the specified control mission, it must be set parameters, otherwise, it is like the computer is not installed and used, and it cannot be operated normally. The parameter setting is carried out by the control surface of the inverter. The control panels of various types of inverters are not only different, but also have many similar places or coordination points. The points of cooperation are:
1. There is a working interface/parameter setting interface switch key, such as the "PRG" button of Fujifilm P11S series inverter, and the "function/data" key of Sunland SBl2 series inverter. The first thing that appears after the inverter is powered on is the working interface, which can be switched to the parameter setting interface by pressing the switch button.
2. There are increase keys "∧" and decrease keys "∨", and most inverters also have shift keys """. The "∧" and "∨" keys are used to increment or decrement the code number when selecting the function code (parameter number). It is used to increase or decrease the value when modifying the parameter value; The "" key is used to select the "bit" to be modified when modifying the parameter value.
3. There is a recognition key, after selecting the parameter code, press the recognition key to enter the parameter value modification law, and press the recognition key to save the modified value at the end of the modification.
4. Both have one or two LED displays, or one LED display plus one LCD display. As long as the inverter of a display, in the parameter setting shape, the parameter code is displayed first, and then converted to the display parameter value after pressing the recognition key; There are two displays, one for the parameter code and one for the parameter value.
5. There is a forward rotation "FWD" button and a rotary "REV" button, which are used to start forward rotation or rotation; However, some inverters only have a working "RUN" button, which is determined by external power.
6. There is a curb "STOP" button. After the above buttons, you can set the parameters or start the inverter to work by connecting the introduction of the inverter.
Figure 3 is a fuss diagram of Fujifilm P11S series inverter and the key display related to parameter setting, in which the "FUNC/DATA" key has the function of acknowledging and saving data; The "RESET" button is the reset key, and the inverter has a very alarm. It is necessary to press the reset button after the problem is relieved to start the work from the beginning.
Before the inverter works, the parameters in the attached table must be set, together with the requirements of the work control, such as closed-loop control, but also set the parameters related to the PID, these parameters will be introduced in a separate article.
All kinds of inverters have a "restore factory value" or "data initialization" parameter code, before the parameter setting starts, you can first go through the parameter code to initialize the parameter value, how, there may be a lot of parameter values just what we need, no need to modify, so as to simplify the setting process.
The inverter is adjacent to the power supply, motor and the required control terminal wiring, and after setting the parameters, it can be put into trial work through the forward or rotary button on the control panel.
|
More on that
|
Contactors play a role in industrial electricity
The contactor is an automatic switch for industrial roofs to control its on/off with a button. The contactor consists of an electromagnetic coil, a static armature, a moving armature, a static contact, a moving contact and a fixing bracket. The principle is that when the electromagnetic coil of the contactor is connected to the communication electricity, a strong magnetic field will be generated to make the center of the coil ...
|
|
Three-phase motor current is too high - LS power generation
First, the power supply problem
1. The power supply voltage is too high
When the power supply voltage is too high, the motor back electromotive force, magnetic flux and magnetic flux density all increase. Since the magnitude of the iron loss is proportional to the square of the magnetic flux density, the iron loss increases, resulting in overheating of the core. And the increase in magnetic flux causes ...
|
|
The role of LS electric contactors
1. It is often used in electric motors as control targets.
2. It is used to control power loads such as factory equipment, electric heaters, working machines and various power units.
3. It has the effect of low voltage release protection.
4. It is suitable for frequent operation and long-distance control, and is an automatic operation.
|
|
Analysis of the working principle of the inverter - LS power generation
The rectified DC voltage of the rectifier contains the pulsating voltage of the power supply 6 times the frequency, and the pulsating current generated by the inverter also changes the DC voltage.
The main power is the power replacement part of the power supply for the asynchronous motor voltage regulation and frequency modulation power supply, and the main power of the inverter can be roughly divided into two ...
|
|
How to operate LS inverters
1. When the power supply is now powered or the inverter is in running condition, do not open the shell of the inverter. Otherwise, an electric shock may occur.
2. When the front cover of the inverter is opened, do not move the inverter. Otherwise, you may be shocked by the high-voltage terminals or exposed charging capacitors. ...
|
|
The protection measures of the power generator inverter for the motor
The protection of the motor by the power converter mainly includes the following aspects: overvoltage protection, undervoltage protection, overcurrent protection, phase loss protection, inverter protection, overload protection, grounding protection, short circuit protection, overfrequency protection and stall protection.
...
|
|
The application of the inverter to supply power to the motor has encountered a problem
A frequency converter is a device that converts power to other frequencies of power supply. The power frequency of our country is 50Hz, in the field of motors, in order to change the speed of the motor, or other performance changes, many motors choose inverter power supply.
...
|
|
Analysis of the problem of excessive current of LS three-phase motor for power generation
First, the power supply problem
1. The power supply voltage is too high
When the power supply voltage is too high, the motor back electromotive force, magnetic flux and magnetic flux density all increase. Since the magnitude of the iron loss is proportional to the square of the magnetic flux density, the iron loss increases, resulting in overheating of the core. And the increase in magnetic flux causes ...
|
|
DC motor troubleshooting - LS power generation
1. The speed of the motor slows down, and the cause of the problem of sound disorder may occur in the electronic speed stabilization device and the motor itself. If there is no problem with the power supply, most of the motor itself has a problem. It can be repaired by replacing the new motor and dismantling and repairing the motor. Dismantling and repairing the motor ...
|
|
The basic method and steps of inverter debugging - power inverter
1. No-load energizing test of inverter
1. Ground the grounding terminal of the inverter.
2. Connect the power input terminal of the inverter to the power supply through the leakage maintenance switch.
3. Check whether the factory display window of the inverter is normal, if it is incorrect, it should be reset.
|
|
Inverter air boost test step - LS power generation
1. Download the control program.
2. Put the inverter in open-loop experimental mode and set the appropriate parameters.
3. Connect the incoming cable of the inverter. The cable on the output side of the inverter is not connected.
4. Push the high-voltage cabinet to the experimental position, close the switch, and ...
|
|
Debugging of basic parameters of inverter - LS power generation
There are many functional parameters of the inverter, and there are generally dozens or even hundreds of parameters for users to choose. In practice, it is not necessary to set and debug every parameter, and most of them only need to use the factory setting value. However, some parameters are very closely related to the application of practice, and some of them are still ...
|
|
The working principle of LS PLC module
When LS PLC is put into operation, its operation process is generally divided into three stages, namely input sampling, user program fulfillment and output rewriting. The completion of these three phases is called a scan cycle. Throughout the operation, the PLC's CPU repeatedly performs the performance at a certain scanning speed on ...
|
|
The internal accessories component of the power production circuit breaker
1. Auxiliary contact: the contact mechanically linked with the main circuit of the circuit breaker and the closing mechanism is mainly used for the display of the circuit breaker and the closing status, and is connected to the control circuit of the circuit breaker through the opening and closing of the circuit breaker to control or interlock its related electrical appliances. For example, output to signal lights, relays, etc.
|
|
Inverter circuit board repair and drawing-free maintenance method - LS power generation
1. Be "confident"
It is necessary to fully understand the principles of some typical circuits and be familiar with them. Guangzhou Kewo Training Center believes that drawings are dead, and the thoughts in the head are alive, able to make analogies, able to reason, and able to touch analogies. For example, switching power supply is always inseparable from ...
|
|
The difference between input reactor and output reactor – LS produces electricity
The rectifier part of the general inverter selects the diode uncontrollable bridge rectifier circuit, and the middle filter part selects the large capacitor as the filter, so the input current of the rectifier is actually the charging current of the capacitor, and the harmonic component is relatively steep and steep.
|
|
Inverter applications and common loads – LS generates electricity
1. Air conditioning load
Office buildings, shopping malls and some supermarkets and factories have central air conditioning, and the electricity consumption of air conditioning is very large during the peak electricity consumption in summer. In hot weather, the electricity consumption of air conditioners in Beijing, Shanghai and Shenzhen accounts for more than 40% of peak electricity. Therefore, with inverter equipment, drag the air conditioning system ...
|
|
Introduction of LS power products
1. Power-related products: medium, low and high voltage electrical products;
(1) Low Voltage Products: Molded Case Circuit Breaker, Air Circuit Breaker, LS Contactor & Overload Relay, Miniature Circuit Breaker, Dual Power Automatic Transfer Switch, Intelligent Motor Protector, Manual Motor Starter, Surge Protection ...
|
|
After the contactor is energized, the start button continuously engages and disconnects ?—— LS generates power
What is the reason why the contactor keeps engaging and disconnecting by pressing the start button after the AC contactor is energized?
In my personal opinion, most of the situation is caused by the wrong coil voltage of the replacement AC contactor, or the purchase of ...
|
|
The five stages of mastery of PLC technology
One. Logical stage
The so-called logical stage is to be able to complete the general logical planning in the relay system, since it is a relay system, so the knowledge of power drag is the foundation of this stage. I personally summarize that the root of learning the relay system lies in the word "grab", the relay system ...
|
|