An integral part of an electrical solid state relay

Create Date: 2024-8-30 12:03:23|Source: LS/Power Generation

Solid state relays consist of three parts: the input circuit, the barrier (coupling), and the output circuit.

                               An integral part of an electrical solid state relay

Input Circuit:

According to the different categories of input voltage, the input circuit can be divided into three types: DC input circuit, communication input circuit and AC and DC input circuit. Some input control circuits also have TTL/CMOS compatibility, positive and negative logic control and inverted phase functions, which can be easily connected with TTL and MOS logic circuits.

For the control signal with a fixed control voltage, a resistive input circuit is selected. The operating current is guaranteed to be greater than 5mA. For the control signal of large change scale (such as 3-32V), the constant current circuit is selected to ensure that the current is more than 5mA reliable operation in the whole voltage change scale.

Barrier (Coupling):

There are two types of blocking and coupling modes for the input and output circuits of solid-state relays: photoelectric coupling and transformer coupling: photodiode-phototriode, photodiode-bidirectional light-controlled thyristor, photovoltaic cell, to complete the control side and the load side barrier control; High-frequency transformer coupling is the self-excited high-frequency signal generated by the input control signal is coupled to the secondary, rectified by the detection wave, and processed by the logic circuit to form the driving signal.

Output Circuit:

The power switch of the SSR is directly connected to the power supply and the load side to complete the on/off switching of the load power supply. The main applications are high-power transistors (Transistor), unidirectional thyristors (Thyristor or SCR), triacs (Triac), power field-effect transistors (MOSFETs), and insulated gate bipolar transistors (IGBTs). The output circuit of the solid state relay can also be divided into DC output circuit, communication output circuit and AC and DC output circuit. According to the load type, it can be divided into DC solid state relay and communication solid state relay. Bipolar devices or power MOSFETs can be used for DC output, and two thyristors or one bidirectional thyristor can be used for communication output. The communication solid state relay can be divided into single-phase communication solid state relay and three-phase communication solid state relay. Communication solid-state relays, according to the timing of on-on and off-, can be divided into random communication solid-state relay and zero-crossing type communication solid-state relay.
More on that
Features of LS SUSOL series circuit breakers Features of LS SUSOL series circuit breakers

Features of SUSOL series circuit breakers: It can be used as the main switch of electrical equipment, and the limit breaking ability is high, Icu=Ics Modular construction of circuit breakers: Tripper replacement (TS series) can be combined in a variety of combinations, such as ...

Meaning and classification of LS Electronic Motor Relay (EMPR). Meaning and classification of LS Electronic Motor Relay (EMPR).

The Electronic Motor Relay (EMPR) is a digital motor maintenance relay with an MCU that has a compact and compact form factor that can be combined directly with a contactor. Through the implementation of real-time data processing, high reliability and high precision can be completed, and it can pass through phase loss, reverse, unbalance, stalled rotor, connection...

LS Electric reached a strategic cooperation with Nandu Power Supply and Changzhou Kunlan LS Electric reached a strategic cooperation with Nandu Power Supply and Changzhou Kunlan

Due to the "new infrastructure" policy, the Chinese government has vigorously promoted the new energy and ESS markets, and according to CNESA, the cumulative electrochemical energy storage scale in China will reach 19.3GW in 2023, which is expected to exceed 20% of the global market. June 3 ...

Precautions for the maintenance of the inverter of the tensile testing machine - LS generates electricity Precautions for the maintenance of the inverter of the tensile testing machine - LS generates electricity

In the course of regularly checking the variable-frequency drive (VFD) of the tensile testing machine, we can visually check the operating status directly from the outside. (1) The ambient temperature is normal, and it is required to be between -10°C and +40 ...

The cause of motor burnout caused by inverter - LS generates electricity The cause of motor burnout caused by inverter - LS generates electricity

In fact, the problems of the motor are not the cause of the motor itself, most of them are caused by the non-standard debugging of the inverter or the wrong inverter motor when the inverter motor is used, etc., mainly due to the following situations: 1. Put the general motor ...

Fault analysis of servo motors – LS power generation Fault analysis of servo motors – LS power generation

1. Problem phenomenon: servo error OL, servo motor can not start, and there is abnormal sound problem analysis and possible causes: (1) Bearing damage, foreign objects falling and stuck, stator magnet bursting and falling or moving tissue jamming caused by the motor itself. (2) ...

LS power terminal is faulty LS power terminal is faulty

From the perspective of application, the function of the terminal block should be achieved: the contact part should be conducted, and the contact should be reliable. The insulating parts should not be conducted, and it is necessary to insulate them firmly. There are three common forms of fatal failure of terminal blocks: ...

The internal accessories component of the power production circuit breaker The internal accessories component of the power production circuit breaker

1. Auxiliary contact: the contact mechanically linked with the main circuit of the circuit breaker and the closing mechanism is mainly used for the display of the circuit breaker and the closing status, and is connected to the control circuit of the circuit breaker through the opening and closing of the circuit breaker to control or interlock its related electrical appliances. For example, output to signal lights, relays, etc.

How LS PLC works How LS PLC works

Although many names such as relays, timers and counters are often used in the ladder diagram programs used by LS PLC, LS PLC does not have these hardware physically, but uses memory and program programming to do logic control and editing, and connects to external machines through output components.

The protection measures of the power generator inverter for the motor The protection measures of the power generator inverter for the motor

The protection of the motor by the power converter mainly includes the following aspects: overvoltage protection, undervoltage protection, overcurrent protection, phase loss protection, inverter protection, overload protection, grounding protection, short circuit protection, overfrequency protection and stall protection. ...

Energy-saving method of ventilator inverter - LS power generation Energy-saving method of ventilator inverter - LS power generation

high-power Although some inverters are fan type inverters, but it is a low-power fan inverter, such an inverter does not have the effect of energy saving, and it is necessary to achieve energy saving must be a high-power inverter, in addition to the high-power fan inverter, it is necessary to meet its ...

Why can't the inverter be equipped with a leakage protector? Why can't the inverter be equipped with a leakage protector?

When using an inverter, a leakage maintainer must not be used. This is a major criterion for the use of frequency converters. Some users choose the corresponding leakage maintainer for the inverter when using the inverter. *The result is: the inverter moves together ...

The method of resetting the fault of the inverter The method of resetting the fault of the inverter

1. Power off the inverter and power it back on; 2. Press the FN button on BOP-2; 3. After the digital input 3, the default setting of 3 is reset to the problem; 4. Press the P button or power off, in the case of no problem; ...

A brief description of the K120S series plc A brief description of the K120S series plc

K120S series PLC product is a unit PLC product introduced to the market by LS in 2004, which has laid a solid foundation in the low-end small machinery supporting industry with its high-performance price ratio. Relying on some special functions of the product, it has also won some industry praise. ...

LS produces common sense of electroplastic case circuit breaker LS produces common sense of electroplastic case circuit breaker

Now in the process of using molded case circuit breakers, it is necessary to understand the rated current of molded case circuit breakers, and the rated current of molded case circuit breakers generally has more than a dozen, mainly 16A, 25 A, 30A, and the height may reach 630A. L ...

Specifications for the use of power converters Specifications for the use of power converters

Operating regulations for power inverters   Maintenance & Installation Work according to the weight of the product. The number of inverter boxes cannot be stacked in excess of the specified number. Install according to the user manual. Do not open the case during transport. Do not place ...

Dealing with intermittent shutdown fault measures - power generation Dealing with intermittent shutdown fault measures - power generation

Because the touch of the network adapter is not good, perhaps due to disturbance and other problems, the DP network that has been used for a long time may show a "transient disconnection" situation, that is, it will be disconnected by an occasional moment, and it will soon recover normally. If OB86 is not downloaded, the CPU will stop during a transient outage. Now all over the option to download a ...

The cause and inspection method of inverter overload tripping - LS power generation The cause and inspection method of inverter overload tripping - LS power generation

1. The main reason for the overload of the inverter (1) Malfunction, the current detection part inside the inverter has a problem, and the detected current signal is too large, resulting in tripping. (2) The mechanical load is overloaded, and the main feature of the overload is that the motor heats up, and it can be ...

Inverter maintenance fault handling method - LS power generation Inverter maintenance fault handling method - LS power generation

1. Not manifested. This situation is more common, generally in the normal condition of the external three-phase power supply, it is the switching power supply of the inverter burned, and the 24 volt power supply on the output board of the inverter terminal can be measured.

Asynchronous motor with inverter - LS generates electricity Asynchronous motor with inverter - LS generates electricity

Before the asynchronous motor is equipped with an inverter, let's take a look at the three major types of mechanical equipment loads: 1. Constant torque load: such as conveyor belts and mixers; When the inverter drags a load of constant torque nature, the torque at low speed should be large enough and the overload capacity should be large enough. If you need ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383