01. The robot switch often jumps or can't close?
Cause:
1. Aging of switches;
2. The switch selection is wrong;
3. The pump is stuck or the motor is short-circuited;
4. The line is aging, short circuit, the line is too small or the phase is missing.
Solution: Turn off the power supply of the control system, and then use the motor around the meter, whether the three-phase of the circuit has a short circuit or grounding phenomenon (pay attention to the frequency conversion output when measuring: remove the frequency conversion output end, so as not to burn out the frequency conversion output module during the test), turn the motor by hand to see if it is stuck, and replace the switch if necessary.
02. Is the robot contactor noisy?
Cause: It is likely to be caused by the uneven contact surface of the contactor, and there is sand or rust on the surface. The consequence will cause a lack of phase, which will lead to the burnout of contactors, switching frequency conversion and other components.
Solution: Knock down the load switch that controls the contactor, and if the sound has not been removed after repeated manual fast switching contactor, it needs to be removed to grind the armature flat, or replace the contactor with a new one.
03. Robot hot relay often jumps?
Cause:
1. Motor overload;
2. Whether the selection is matched;
3. Whether it is aging and whether the main line is too small.
Solution: Check whether the selection of the motor and the thermal relay match, check the motor to ensure that the motor is normal, and this phenomenon needs to be replaced with a new one. Replace the matching main line with a new one.
04. Is the robot contactor or relay engaged abnormally?
Cause:
1. Coil zero loop break;
2. The intermediate relay head is broken.
Solution: Check the line and replace it with a new trunk head.
05. Robot inverter often reports faults?
Cause:
1. The parameter setting is incorrect;
2. Aging of inverter;
3. The water pump is overloaded;
4. Lack of phase;
5. Loose lines.
Solution: Reset the inverter first, if the same fault occurs again in a short time, it means that the inverter can not continue to work until the work is released. The fault code generated by the inverter is recorded, the fault is solved according to the manual, the circuit is tightened once, and the three-phase current is measured to see if it is balanced. The inverter needs to be replaced if the inverter is burned out due to the lack of phase of the power supply, or the inverter is aging.
06. The output and input points of the robot maintenance controller are abnormal or cannot operate normally?
Cause:
1. The input and output points of the controller operate frequently for a long time, resulting in the burning of the contacts inside the controller;
2. Due to the strong current of the contact;
3. There is an error in the program or the controller has been burned.
Solution: It is necessary to update the program of the controller to change the burned input and output points to the standby electric shock through the software, and replace the controller if necessary.
07. Yaskawa robot maintenance pressure is unstable and fluctuating?
Cause:
1. The parameters of the controller are not adjusted;
2. The efficiency of the water pump is too low.
08. The robot system is sometimes good and sometimes bad, and cannot operate normally?
Cause:
1. The appearance of loose lines;
2. Aging of components.
|
More on that
|
Yaskawa servo motor - the working principle and basic requirements of servo drive
At present, the mainstream servo drives all use digital signal processors (DSPs) as the control core, which can realize more complex control algorithms and realize digitalization, networking and intelligence. Power devices generally use the drive circuit designed with intelligent power module (IPM) as the core.
|
|
Yaskawa Robot was launched in China to create a mutually beneficial and win-win pattern
China's industrial manipulator (15.620, 0.00, 0.00%) market capacity continues to develop, and overseas robot manufacturers have surged production capacity to solve China's requirements. As one of the "four families" of intelligent robots, Yaskawa Electric has accelerated the rational layout of Chinese artificial intelligent sales market, ...
|
|
Yaskawa servo drive failure and repair
1. The motor runs faster in one direction than in the other;
(1) Cause of failure: The phase of the brushless motor is wrong.
Solution: Detect or detect the correct phase.
(2) Cause of failure: When not used for testing, the test/deviation switch hits the test position. ...
|
|
Analysis of common fault codes of Yaskawa servo drive
A.020 A.02 User Parameters and Number Check Abnormalities The data of the internal parameters of the servo unit is abnormal
A.021 A.02 Parameter Formatting Abnormality The data of the internal parameters of the servo unit is abnormal
A.022 A.02 Abnormal system parameters and number check The data of the internal parameters of the servo unit is different ...
|
|
How to adjust the multi-stage speed of Yaskawa V1000 inverter?
Yaskawa Inverter A1000 User Guide 1. Description of the operator: (1). Keyboard description:
【ESC】Function:
1. Return to the previous screen;
2. Shift the bit that needs to be changed when setting the parameter number to the left;
3. If you press and hold it, you can ...
|
|
What are the faults of Yaskawa inverter?
The following are the common faults of the inverter and how to deal with them
1) OC Over Current
This is the most frequent failure of the inverter, and it is divided into external and internal causes in the analysis of causes. External causes: mechanical structure and parameter setting, open-loop control ...
|
|
Yaskawa MOTOMAN servo drive fault repair case summary (3-4)
3. When the oscilloscope checks the current monitoring output of the driver, it is found that it is all noise and cannot be read;
Cause of failure: The current monitoring output is not isolated from the AC power supply (transformer).
Solution: It can be detected and observed with a DC voltmeter.
4、LE ...
|
|
How to wire Yaskawa servo motor B1B2?
1. First of all, connect the terminal block of Yaskawa servo B1B2, in which the B1 terminal receives the power supply and the B2 terminal receives the signal;
2. Then, connect the terminal block of Yaskawa servo B1B2, wherein B1 terminal receives power supply, and B2 terminal receives signal;
3. After the wiring is completed, ...
|
|
Yaskawa servo manual control motor rotation method
1. Open the control panel of Yaskawa Servo and select Manual Mode.
2. Manually rotate the rotor of the motor to calibrate the position of the motor;
3. Press the start button on the panel to let the motor start to rotate;
4. Using the speed adjuster on the panel, adjust the motor ...
|
|
Yaskawa inverter – how to check for inverter failure
1. Static test
1. Test the rectifier circuit
Find the P and N ends of the DC power supply inside the inverter, adjust the multimeter to the resistance X10 gear, connect the red watch rod to P, and separate the black watch rod to R, S, T. Instead, take the black watch rod ...
|
|
Inverter wiring method
First, the wiring of the main circuit
1. The power supply should be connected to the R, S, and T terminals at the input end of the inverter, and must not be connected to the output terminal (U, V, W) of the inverter, otherwise the inverter will be damaged. After wiring, the fragmented wires must be cleaned, and the fragmented wires may cause abnormalities.
...
|
|
How to set the parameters of Yaskawa H1000 inverter multi-stage speed?
Yaskawa H1000 inverter parameter model setting steps:
Yaskawa H1000 hoisting using debugging steps (with PG ) No. Name Optimal value
A 1-02 Control Mode Selection 3: With PG Vector Control
A 1-03 Initialization 2220: 2 Wire Initialization
A ...
|
|
Yaskawa Robot - the basic function of the robot control system
(1) Memory function: store operation sequence, motion path, motion mode, motion speed and information related to production process;
(2) Teaching function: offline programming, online teaching, indirect teaching. There are two types of online teaching: teaching box and guided teaching;
(3) With ...
|
|
The operation faults of Yaskawa inverter W1000 and the solutions
(1) Operator display: oPE01
Fault name: The setting of the inverter capacity is faulty, and the setting content of O2-04 (inverter capacity selection) is inconsistent with the actual inverter capacity.
The reason is that the setting content of O2-04 (inverter capacity selection) is the same as the actual inverter capacity.
|
|
Yaskawa inverter - how to maintain high-voltage inverter?
1. Use a vacuum cleaner with a plastic nozzle to thoroughly clean the inside and outside of the inverter cabinet to ensure that there is no excessive dust around the equipment.
2. Check the ventilation and lighting equipment of the frequency conversion room to ensure that the ventilation equipment can operate normally.
3. Check that the connection between the cables inside the inverter should be correct and acceptable.
|
|
Yaskawa servo drive parameters
PN000 function selection N.0010 (setting value) 0th position: set the direction of rotation of the motor; Set "1" to change the rotation of the motor in reverse. 1st position: Set the control mode to: "1" position control mode.
PN200 Command Pulse Input Mode Function Selection N.0101 (Set Value) "1" Positive ...
|
|
Yaskawa Robotics - Introduction to the six subsystems of industrial robots
Industrial robot is a multi-degree of freedom machine device, can automatically perform work, according to its own power and control ability to achieve various functions, by the mechanical part, sensing part, control part and other three parts, these three parts are divided into six subsystems, namely:
1. Drive...
|
|
Yaskawa servo motor - the selection step of servo control
1. Determine mechanical specifications, load, rigidity and other parameters;
2. Confirm the action parameters, stroke, accuracy, acceleration and deceleration time, cycle, moving speed, etc.;
3. Select motor inertia, load inertia, motor axis conversion inertia, and rotor inertia;
4. Select the motor back ...
|
|
YASKAWA The success of industrial automation starts here
Founded in 1989, Yaskawa Motoman is a leading industrial robotics company in the Americas. With more than 400,000 Motoman industrial robots, 15 million servos and 26 million inverter drives installed worldwide, Yaskawa provides automation products and ...
|
|
Product classification of Yaskawa servo motors
Yaskawa Electric is a professional manufacturer in the field of motion control, is the first company in Japan to do servo motors, its products are known for stable and fast, cost-effective, is the world's largest sales, the most used servo brand. In China, Yaskawa Servo has occupied the largest market for many years ...
|
|