    Product Introduction
    They have the advantages of smooth and reliable operation, tight shut-off and long service life.
Product Description
The EZH (Spring Closed) and EZHSO (Spring Open) series regulators are precision-piloted, pressure-balanced soft-seat regulators. These regulators are used for high-pressure natural gas transmission/city gate stations, high-flow distribution systems, and power plant gas supply. They have the advantages of smooth and reliable operation, tight shut-off and long service life.
Fisher/Fisher EZH and EZHSO series
peculiarity

Completely air-free – all gases are vented to downstream systems with a pilot-operated control system, so no harmful exhaust gases are emitted into the air.

Gas Cut-off – Sharp metal plugs and soft seats provide gas shut-off and can be used in applications that require positive pressure shut-off, such as end systems.

Long service life in severe conditions – The metal plug design keeps particles and debris away from the soft seat, providing superior resistance to particle erosion and extending service life.

Failure Mode Options—Maximize uptime with the EZHSO-style spring-open design and protect downstream assets with the EZH-style spring-off design. For many customers, the combination of EZHSO regulators and EZH monitors maximizes the effectiveness of both devices.

Precise Pressure Control—Provides stable, accurate downstream pressure control regardless of load or inlet pressure changes.

Quiet operation—The Whisper Trim™ cage option reduces source noise by up to 8 dBA, eliminating the need for costly tubing treatments such as insulation, buried valves, and the use of noise-only enclosures.

Complete pressure ratings—1500 psig/103 bar equal inlet and outlet pressure ratings for easier selection without the need for special start-up or shutdown procedures.

Integrated quick shut-off configuration—In the event of overpressure and loss of pressure, the EZHOSX and EZHSO-OSX models stop the gas supply by shutting off the gas.

This article introduces the Fisher/Fisher EZH and EZHSO series products, if you are interested in Fisher/Fisher pressure regulators, please also contact our customer service, we look forward to your call, hope our technology and service can bring you a better experience.

The company has been customer-centric, the concept of creating value for customers, winning the market with quality and service, and sincerely hopes to cooperate with all sectors of society to create success, create brilliance together, and work together to create a better tomorrow! In line with the concept of credibility and service-oriented, the company warmly welcomes new and old customers to inquire, visit and negotiate business!

More on that
Fisher/Fisher 3582I Valve Positioner Fisher/Fisher 3582I Valve Positioner

Flexible module design – The 3582 Series units can be upgraded to the Model 3582i Electro-Pneumatic Positioner in the field to replace the measurement module with the Model 582i Electro-Ptic Converter Assembly (1). The Type 582i electric-gas converter is attached to the housing of the positioner and provides a very economical ...

Fisher/Fisher DVC6200 valve positioners Fisher/Fisher DVC6200 valve positioners

THE FIELDVUE DVC6200 DIGITAL VALVE CONTROLLER IS A HARTR COMMUNICATION INSTRUMENT USED TO CONVERT A TWO-WIRE 4-20 MA CONTROL SIGNAL INTO A BAROMETRIC OUTPUT FOR SUPPLY TO THE ACTUATOR. It can also be easily retrofitted to replace most Fisher and non-Fisher pneumatic actuators...

Fisher/Fisher 1061 Pneumatic Pilot Rotary Actuator Fisher/Fisher 1061 Pneumatic Pilot Rotary Actuator

The Fisher 1061 actuator is used to operate splined shaft rotary control valves such as Fisher Vee-Ball™ valves, eccentric butterfly valves, and butterfly valves. The actuator/body connection of this actuator can be set either as push-down open or push-down as off. In addition, 1061 ...

Fisher/Fisher WhisperFlo Pneumatic Noise Cancelling Internals Fisher/Fisher WhisperFlo Pneumatic Noise Cancelling Internals

Designed for applications that require superior noise reduction, Fisher WhisperFlo trims represent the most advanced solutions available. Control valves with WhisperFlo trims provide additional suppression of pneumatic noise in the harshest high-pressure precipitation or gas applications. With phase ...

Fisher/Fisher 3610J Pneumatic, Single-Acting Positioner Fisher/Fisher 3610J Pneumatic, Single-Acting Positioner

The Fisher 3610J pneumatic positioner can be used with a single-acting rotary actuator to precisely locate control valves used in throttling applications. These positioners are rugged and provide valve positioning proportional to the pneumatic input signal or DC current input signal and as a whole ...

Fisher/Fisher Model R222H Primary Regulator for LPG Fisher/Fisher Model R222H Primary Regulator for LPG

 Introduction: The Fisher/Fisher Model R222H is a one-stage regulator that offers 65% higher flow and 40% smaller volume than standard compact regulators for use in underground tanks or airchambers where space is limited. Approved by Underwriters Laboratories (UL) (United States Safety Testing Laboratories Inc. ...

Fisher/Fisher multi-way valves Fisher/Fisher multi-way valves

Fisher multi-way valves and actuators divert fluid from a single fluid line to a test outlet or sampling device. A single multi-flow selector acts as a manifold that brings together eight fluid lines at once. Actuator is an electronic device designed to control and monitor the operation of multiple flow selectors.

Fisher 656 pneumatic actuator Fisher 656 pneumatic actuator

It can produce up to 5.3 kN (1,200 lbf) of thrust, depending on the construction. Depending on the size, travels up to 105 mm (4 1/8 inches) are available. The actuator base has four screw holes that allow for the installation of brackets or plates. With a wide selection of springs, it is suitable for almost any ...

Fisher/Fisher Model R231A Integrated Two-Stage Regulator Fisher/Fisher Model R231A Integrated Two-Stage Regulator

The Model R232A regulator is certified by Underwriters Laboratories (United States Safety Testing Laboratories, Inc.) for use in LPG systems. The regulator is designed to reduce tank pressure through an integrated two-stage system that provides an 11-inch water column of outlet pressure. For the people ...

Fisher/Fisher 1301 regulator Fisher/Fisher 1301 regulator

The 1301 series is a high-pressure pressure regulator used to supply air to instruments. It is equipped with a pressure gauge interface and can be equipped with a pressure gauge as an option. Connection size: NPS 1/4 Regulated pressure range: .0.69 to 34.5 bar/10 to 500 psig Maximum inlet pressure: 414bar/6000psig This article describes the fee ...

Fisher/Fisher Model R622 Pressure Reducing Regulator Fisher/Fisher Model R622 Pressure Reducing Regulator

The Fisher Model R622 direct-acting, spring-loaded regulator provides economical pressure reduction control in a variety of residential, commercial, and industrial applications. These regulators can be used for natural gas, manufactured gas, or LPG with the same inlet and outlet pressure capabilities. peculiarity Compact...

Fisher/Fisher Valve DVC6010F-SCAD Fisher/Fisher Valve DVC6010F-SCAD

F1 ELDVUEDVC6000 Series Digital Valve Controller (Fig. 1) and Actuator. The digital valve controller receives the valve stroke position in Figure 2) is a communicative, microprocessor-based conversion of electrical signals into feedback, as well as air supply pressure and pneumatic pressure of the actuator. This makes ...

Fisher/Fisher Series 1805 Series Back Pressure Regulators and Relief Valves Fisher/Fisher Series 1805 Series Back Pressure Regulators and Relief Valves

The Series 1805 pressure relief valve is ideal for farm faucet applications where a pressure relief valve is required between the primary and secondary regulators. The Series 1805 pressure relief valve is suitable for use with natural gas, air, propane, or any medium that is compatible with internal valve components. Relief ranges from 5 to 125 psig/0. ...

The Fisher/Fisher 585C actuator is configured with DVC6200 valves The Fisher/Fisher 585C actuator is configured with DVC6200 valves

The Fisher Model 585C actuator is typically equipped with a DVC6200 digital valve controller or a 360OP/P or I/P analog positioner. Can be used with a top-mounted or side-mounted manual handwheel (depending on the size of the actuator). Features: Produces up to 111 kN (25,000 lb ...

Fisher/Fisher Model MR105 Direct-Acting Vacuum Liquid Regulator Fisher/Fisher Model MR105 Direct-Acting Vacuum Liquid Regulator

The Model MR105 Direct Acting Pressure Reducing Regulator is a high-flow, multi-purpose regulator designed to provide fast and economical pressure control for a wide range of applications with different fluid media such as liquids, air, and gases. The MR105 valve is the most important for response speed.

Fisher/Fisher 67C Instrument Regulator Body material is optional Fisher/Fisher 67C Instrument Regulator Body material is optional

Introduction: Fisher/Fisher 67C Instrument Regulators Direct Acting Regulators and Filter Regulators are commonly used to deliver reduced, continuously controlled pressure to pneumatic and electropneumatic controllers and other instruments. These regulators are suitable for most air or gas applications. Other application packages ...

Fisher/Fisher Model 630 Regulator Fisher/Fisher Model 630 Regulator

The Fisher Model 630 Big Joe™ Regulator is a direct-acting, spring-loaded decompression regulator with body sizes NPS 1 & 2 / DN 25 & 50 for a maximum inlet pressure of 1500 psi/103 bar and an outlet of 3-500 psi/0.21-34.5 bar ...

Fisher/Fisher 3620JP Electrical Double Acting Positioner Fisher/Fisher 3620JP Electrical Double Acting Positioner

The Fisher 3620JP Electrical Double Acting Positioner can be used with rotary actuators and locate control valves used in throttling applications. The positioner is mounted to the actuator housing. The positioner is rugged and provides valve positioning proportional to the DC current input signal. Fee...

Fisher/Fisher dirty service trims Fisher/Fisher dirty service trims

Fisher dirt service trims are designed for dirt and cavitation applications. Cavitation is eliminated with a range of flow limits and extensions, allowing particles up to 19mm (3/4in) in diameter to pass through without clogging. Each trim stage has a sequentially increasing flow ...

Fisher/Fisher Control Valve - V150S-V-Ball Rotary Flange Control Valve Fisher/Fisher Control Valve - V150S-V-Ball Rotary Flange Control Valve

Fisher Control Valve V150S V-Ball Rotary Flange Control Valve, which uses rugged construction, highly abrasion-resistant trim materials, and unrestricted DC access, makes this valve ideal for controlling abrasive slurries. This design is particularly effective in reducing ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top