Introduction: Fisher/Fisher 67C Instrument Regulators Direct Acting Regulators and Filter Regulators are commonly used to deliver reduced, continuously controlled pressure to pneumatic and electropneumatic controllers and other instruments. These regulators are suitable for most air or gas applications. Other applications include providing reduced pressure for pneumatic chucks, air nozzles, and spray guns.
Product parameters
Body material is optional
Series 67C: Aluminum
67CS Series: Stainless steel
Optional structure
67C and 67CS: Stand-alone regulators
67CR & 67CSR: Internal pressure relief with soft seat
67CF and 67CFS: with filter
67CFR and 67CFSR: Internal pressure relief with filter and soft seat
Body size and port connection: 1/4 NPT
Maximum Inlet Pressure (Body Rating): 250 psig/17.2 bar for all models except 67CS and 67CSR
Type 67CS and 67CSR: 400 psig/27.6 bar
Maximum Emergency Outlet Pressure: 50 psi/3.4 bar above outlet pressure setpoint
Pressure method: internal pressure
Temperature range
NBR: -40 to 180°F/-40 to 82°C
FKM: 0 to 300°F/-18 to 149°C
Silicone rubber (VMQ) diaphragm, cryogenic bolt-on: -60 to 180°F/-51 to 82°C
Approximate weight
67C, 67CR, 67CF, and 67CFR: 1 lb/0.5 kg
67CS and 67CSR: 2.5 lb/1.1 kg
67CFS and 67CFSR: 4 lb/1.8 kg
Features:
Compact design
Panel mounting
Voltage regulator for instruments
Stainless steel construction is optional
Internal pressure relief
When the supply pressure is lost, the pressure is relieved from the outlet using the Smart Bleed™ internal check valve
Sturdy construction
Fasteners are corrosion-resistant
This article introduces the Fisher/Fisher 67C instrument pressure regulator products, if you are interested in the Fisher/Fisher pressure regulator, please also contact our customer service, we look forward to your call, hope our technology and service can bring you a better experience.
Our customer-centric service concept: the pursuit of a full range of services is a high-quality, high-standard service, the pursuit of every detail of the service process. It is impossible for interests to blossom into brilliant flowers from lies. Only by being professional and careful in every process, every action and every detail of the service can we meet or even exceed customer expectations and make customers satisfied and recognize us. Honest, professional, affordable, and fast, so you can rest assured. "Honest and professional service, affordable price, continuous improvement" is our service philosophy. Safety relay products, if you are interested in Fisher/Fisher voltage regulators, please also contact our customer service, we look forward to your call, hope our technology and service can bring you a better experience.
|
More on that
|
Fisher/Fisher MR98 Series Back Pressure Regulators, Relief and Differential Pressure Relief Valves
The MR98 series is suitable for back- or pressure-relief applications in liquid, gas, air, and vapor applications. Models MR98L, MR98H and MR98HH are direct-acting spring valves. Models MR98LD, MR98HD and MR98HHD utilize additional load pressure to maintain differential pressure relief, ...
|
|
Fisher/Fisher OSE Quick Release Valve Remote alarm function
Introduction: The Fisher/Fisher OSE quick shut-off valve quickly shuts off the airflow in the event of overpressure or loss of pressure. It is ideal for applications that require complete cut-off protection, precise sealing, fast response, high impact and shock resistant gases, top-mounted design, easy in-line maintenance, and savings.
|
|
Fisher/Fisher Models 1808 and 1808A Pressure Relief Valves or Back Pressure Regulators
Fisher's 1808 Spherical and 1808A Angle-Directed Back-Pressure Regulators or Relief Valves are economical and compact for use in gas or liquid applications to maintain pressure on oil-gas separators, or for pressure relief applications in gas distribution systems.
peculiarity
The design is simple and reliable
Compact and lightweight
Square...
|
|
Fisher/Fisher Cavitrol™ III trims
Fisher Cavitrol III trims are designed for clean, cavitation applications with a maximum pressure drop of 207 bar (3000 psi). The cage in the trim includes a large number of specially shaped, radially arranged holes to reduce turbulence and maintain the overall pressure drop, thereby controlling or eliminating cavitation.
|
|
Fisher/Fisher DVC6200 valve positioners
THE FIELDVUE DVC6200 DIGITAL VALVE CONTROLLER IS A HARTR COMMUNICATION INSTRUMENT USED TO CONVERT A TWO-WIRE 4-20 MA CONTROL SIGNAL INTO A BAROMETRIC OUTPUT FOR SUPPLY TO THE ACTUATOR. It can also be easily retrofitted to replace most Fisher and non-Fisher pneumatic actuators...
|
|
Fisher Model 155 High Pressure Steam Pressure Reducing Valve
Low-noise steam pressure reducing valves controlled by multi-stage trim trims are used in boiler start-up and steam generation processes
peculiarity
Pressure-sealed bonnet.
Low-maintenance gland filled with pure graphite (re-tightened).
Polished stem.
Hard-faced rails.
Pressure-balanced spool.
Hard-faced sealing surfaces.
...
|
|
Fisher/Fisher Model R222H Primary Regulator for LPG
Introduction: The Fisher/Fisher Model R222H is a one-stage regulator that offers 65% higher flow and 40% smaller volume than standard compact regulators for use in underground tanks or airchambers where space is limited. Approved by Underwriters Laboratories (UL) (United States Safety Testing Laboratories Inc. ...
|
|
Fisher 167D-2594-179127 Switching Valve 167DA Position Retention Valve
Fisher 167D-2594-179127 Switching Valve 167DA Retaining Valve The 167D Series Switching Valve is typically used to provide reduced, stable vaporized liquid pressure to pilot-acting controllers and other pneumatic instruments.
Models 167D and 167DS valves are two-way switching valves. 167DA and 167DA ...
|
|
Fisher/Fisher 8580 High Performance Butterfly Valve
Fisher™ 8580 High Performance Butterfly Valve |
The Fisher 8580 High Performance Butterfly Valve features enhanced shut-off with an eccentric mounting butterfly plate with soft or metal seals. This control valve provides an excellent throttling and switching performance experience.
Authentication...
|
|
Fisher/Fisher DVI Vapor Regulated Desuperheater
The Fisher DVI desuperheater is injected with a water jet at the venturi outlet section to ensure thorough mixing as well as rapid atomization. DVI desuperheaters can be easily installed between flanges in steam pipes from DN25 to DN600 (1 to 24 inches). No moving parts, water fill mode for fast, ...
|
|
The Fisher/Fisher 585C actuator is configured with DVC6200 valves
The Fisher Model 585C actuator is typically equipped with a DVC6200 digital valve controller or a 360OP/P or I/P analog positioner. Can be used with a top-mounted or side-mounted manual handwheel (depending on the size of the actuator).
Features:
Produces up to 111 kN (25,000 lb ...
|
|
Fisher/Fisher D2T FloPro Control Valve 2250 psig pressure drop force
Introduction: The Fisher/Fisher D2T valve is best suited for use as a dump valve for gas separators and scrubbers. It is also suitable for other high-pressure applications in natural gas production, compression and processing.
Features:
Optional 1 NPT end connection.
Have a C ...
|
|
Fisher/Fisher D is threaded to the DA control valve
Introduction: Fisher/Fisher D and DA single seat high pressure valves are widely used in the oil and gas production industry. These valves are particularly suitable for throttling or on/off control of fluids that contain sand, viscous oil and gas, or have a tendency to clog valve trims. DA valves are also suitable for corner pipes or other applications that require self-draining.
|
|
Fisher/Fisher S402Y Regulator Body size NPS3/4 1NPT
Description: The Fisher/Fisher Model S402Y Pressure Regulator Direct Acting Reed Regulator provides economical pressure reduction control in corrosive environments in a variety of residential and small commercial applications. Typically, the Model S402Y is used to reduce the pressure of gas distribution to 4.5 in w.c. to 2.5 ps ...
|
|
Fisher/Fisher pipe silencer
Complete Fisher pipe silencers provide superior noise reduction performance for applications where valves generate a lot of noise. Once installed, the total system pressure drop is split between the valve and the silencer. This allows the valve to operate at a lower pressure drop ratio, reducing the noise generated during the flow through the control valve.
|
|
Fisher/Fisher V260 Control Valve
The Fisher V260 is a full-bore control valve with a bottom-up design that maximizes pressure, flow, and process control. Integral borehole silencers are used to control noise and vibration generated by high-pressure drop liquids and gases. The spline shaft is connected with the actuator, which reduces the movement loss. ...
|
|
Fisher/Fisher D3 FloPro Control Valve
The Fisher D3 Control Valve is a compact, rugged valve for on/off or throttle control with FloPro technology and the choice of pneumatic or electric control. This valve is best used as a tipping valve for gas separators and scrubbers. At the same time ...
|
|
Fisher/Fisher CSB700 Pressure Reducing Regulator Overvoltage Protection
Description: The Fisher CSB700 Pressure Reducing Regulator Direct Acting Spring-Loaded Regulator is designed for a wide range of pressure reduction applications. The regulator offers a great deal of flexibility because it offers a variety of body sizes and end connections, outlet pressure settings, and ...
|
|
Fisher/Fisher Models 1301F and 1301G High Voltage Regulators
Models 1301F and 1301G are self-acting, high-pressure regulators that can be used in applications where the pressure of high-pressure gases must be reduced, used as a pilot supply pressure in a pilot-acting regulator, or as a load pressure in a pressure-loaded regulator. The Model 1301F and 1301G regulators are also ...
|
|
Fisher/Fisher easy-Drive™ Actuators
With Fisher easy-Drive actuators, you can rest easy knowing that your control valve will perform as intended, regardless of application conditions. This design is based on extensive field testing and application design expertise.
specification
Actuation mode: linear, electric
Region...
|
|