Fisher
Left boxProduct DisplayRight box
  • Fisher/Fisher Valve 2100 Level Switch
  • Fisher/Fisher 8590 High Performance Butterfly Valve Multiple connections
  • Fisher/Fisher HP Series Control Valves
  • Fisher 656 pneumatic actuator
  • Fisher/Fisher V500 Eccentric Plug Valve Fugitive emissions
  • Fisher/Fisher 1061 Pneumatic Pilot Rotary Actuator
  • Fisher/Fisher Whisper Trim I Valve Cage™
  • Fisher/Fisher 67C Series High Pressure Regulator LPG
  • Fisher/Fisher two-stage regulator model R632A Inlet pressure 17.2 bar
  • Fisher/Fisher multi-way valves
  • Fisher/Fisher 657 and 667 diaphragm actuators
  • Fisher/Fisher easy-e EW Series Control Valves
  • Fisher/Fisher 4200 Electronic Position Transmitter 4-20mA
  • Fisher/Fisher 630 Series Regulators Inlet pressure 103 bar
  • Fisher/Fisher V250 Control Valve Features linear
  • Fisher/Fisher H200 Series Pressure Relief Valves
  • Fisher/Fisher AV III Micro-Flat trims
  • Fisher/Fisher Model 749B Conversion Manifold Assembly Air supply: 15 psig
  • Fisher/Fisher Models 1301F and 1301G High Voltage Regulators
  • Fisher/Fisher 585C piston actuator
  • Fisher/Fisher 25 VenTemp desuperheater
  • Fisher/Fisher Model R222H Primary Regulator for LPG
  • Fisher/Fisher D is threaded to the DA control valve
  • Fisher/Fisher 3582i Single-Acting Electro-Pneumatic
  • Fisher/Fisher 627 Series Commercial/Industrial Regulators
  • Fisher/Fisher Model 310A Pressure Reducing Regulator Inlet pressure 102 bar
  • Fisher/Fisher 657 and 667 Spring Diaphragm Pneumatic Actuators
  • Fisher/Fisher C1 Pneumatic Controllers & Converters
  • Fisher/Fisher Model 1290 Vapor Recovery Regulator
  • Fisher/Fisher 670 Series Panel Mount Load Regulators
  • Fisher/Fisher YD and YS 3-Way Cage Pilot Valves Socket welded connections
  • Fisher/Fisher DVC6200P PROFIBUS PA Digital Valve Positioner
  • Fisher/Fisher Model 630 Regulator
  • Fisher/Fisher Vee-Ball™ V150 Flanged Control Valve is SIL compliant
  • Fisher/Fisher Pressure Regulator Series 310A
  • Fisher/Fisher D3 FloPro Control Valve
  • Fisher 3610JP Pneumatic Double Acting Valve Positioner
  • Fisher/Fisher DSA Vapor Regulated Desuperheater Pressure Rating ASME
  • Fisher/Fisher Model 1190 Low Pressure Hermetically Sealed Regulator Outlet pressure 5.2 bar
  • Fisher/Fisher CSB700 Pressure Reducing Regulator Overvoltage Protection
  • Fisher/Fisher 1301F/G Series High Pressure Regulator Weight 3.6kg
  • Fisher/Fisher Solenoid Valves ASCO™ 210 Series
  • Fisher/Fisher 4660 Pneumatic Pilot Operated Pressure Controller
  • Fisher/Fisher Model R622 Pressure Reducing Regulator
  • Fisher/Fisher Model 92C Self-Operated Control Valve
  • Fisher/Fisher Model 99 Pressure Regulator Outlet pressure 6.9 bar
  • Fisher/Fisher FieldQ VOS Valve Operating System (VOS) and rack and pinion actuators
  • Fisher/Fisher Control Valve - V150S-V-Ball Rotary Flange Control Valve
  • Fisher/Fisher Models 119, 119EZ, and 119EZS Changeover Valves
  • Fisher/Fisher V260 Control Valve
line Last next sign
Left boxBrand ProfileRight box
FisherFisher Control Equipment International Ltd. was founded in 1880. At that time in Marshalltown, Iowa, United States, founder Wiliam Fisher invented the first pump regulator, sowing the seeds of Fisher in the small town. Since then, Fisher has achieved tremendous growth over the years and has become a recognized brand.

Emerson purchased Fisher in 1992 and merged with Rosemount, another world leader in process instrumentation, to form Fisher-Rosemount to better meet our customers' requirements for a complete range of applications and process control

In April 2001, Fisher-Rosemount changed its name to Emerson Process Management, a brand of Emerson Process Management, part of Emerson's business platform.

Through Fisher, Emerson provides customers with time-tested and innovative solutions to meet their needs. Whether you're in the oil & gas, refining, petrochemical & chemical, food & beverage, pulp & paper, life sciences, power or pharmaceutical, our comprehensive range of products and innovative technologies will satisfy you.

Fisher valves provide innovative, time-tested solutions that help customers reduce equipment maintenance costs, reduce capital requirements, cut compliance costs, and increase process availability. This will be achieved through world-class products including: Fisher Positioners, FSHER Regulators, FSHE Control Valves, Fisher Valves, Fisher Regulators, IHER Pressure Reducing Valves, ISHER Control Valves, Fisher Instrumentation and Performance Services, which are among the most reliable products in the process control industry.
Left boxBrand NewsRight box
Fisher Fisher - Hazards and Protection of Abnormal Pressure Boost in the Cavity of Gate Valves
Fisher Fisher - Hazards and Protection of Abnormal Pressure Boost in the Cavity of Gate Valves
Gate valves usually have single ram, double ram, wedge, parallel and other structural designs, among which wedge double ram (Z42, Z62 series) and wedge elastic ram (Z40, Z60 series) are widely used, the former when the gate is closed, the gate automatically fits the valve seats on both sides, and automatically compensates the processing position of the wedge angle.
Debugging steps for the Fisher Locator (DVC6200).
Debugging steps for the Fisher Locator (DVC6200).
The Fisher Positioner DVC6200 is Emerson's valve-mounted, digital valve controller that intelligentizes the entire control valve assembly. Take control of your process with important, real-time information that can be accessed from anywhere in the loop. Also able to get a problem before it becomes ...

Fisher Fisher - Electric Actuator Selection
Fisher Fisher - Electric Actuator Selection
Electric actuator, also known as valve electric device, it is a name in different industries, called valve electric device in the industrial pipeline valve industry, and called electric actuator in the instrument industry, but now there is no clear distinction in the industry.

Fisher Fisher - Seven common problem solutions for pneumatic butterfly valves
Fisher Fisher - Seven common problem solutions for pneumatic butterfly valves
Seven common problem solutions for pneumatic butterfly valves: 1. The butterfly valve is installed in the pipeline, and the best position is vertical, but it cannot be reversed. 2. It is recommended to use the special flange of the butterfly valve, that is, the HGJ54-91 socket welded steel flange. 3. Butterfly valve stem installation ...

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top