Uses and technologies of cable junction boxes – Wienal

Create Date: 2024-8-30 12:03:23|Source: Woehner/Wiehner

XBT series mine flameproof communication cable distribution box has the characteristics of small size, reasonable cable import and export, and wide coverage. Each distribution box has 4-10 inlet and outlet line bells, which is suitable for HUYV type mine signal cable in the coal mine containing sexual gas (methane) mixture (non-mining face), for communication and signal distribution purposes.

                               Uses and technologies of cable junction boxes – Wienal

1. The device frame is made of hinge structure, which is installed in the shell through screws, and the wiring is sensitive, convenient and reliable;

2. The terminal base body is made of plastic, with good insulation and high strength, and the connection between the terminal post and the insulating seat is firm and reliable.

Third, the main technical parameters A

Standard: 10 pairs, 20 pairs, 30 pairs, 40 pairs, 50 pairs (number of binding posts);

B Rated voltage (V): [AC 12, 24 ] [DC 12, 24, 36, 48, 60];

C Rated current (A): 0.1——1.0;

D AC power rated frequency (Hz): 50;

E Work system: long-term.

More on that
Common Bus Application Considerations – Wiener Common Bus Application Considerations – Wiener

  In the common DC bus system of multiple inverters, especially the common DC bus of inverters of different power levels, it is very important that the connection between the bus bars is maintained by fuses. When one of the inverter power equipment in the common bus is damaged by short circuit breakdown, the other inverter bus ...

The advantage of busway over cable in construction - Wienal The advantage of busway over cable in construction - Wienal

Modern power supply lines play a very important role like the aorta of the human body, and if something goes wrong, it can have serious consequences. Before the 80s of the 20th century, many stable cables were used in modern construction. With the rapid development of the city, the power load of the building ...

Ship unloader distribution cabinet convergence mode - Wiener Ship unloader distribution cabinet convergence mode - Wiener

In the hardware layout planning of the ship unloader distribution cabinet, in order to omit the wiring slot pawn, save time and effort in wiring, prevent wiring errors, and make the distribution cabinet beautiful and useful, the circuit breaker inlet end in the distribution cabinet will use the confluence method. Here are a few commonly used ways to combine the flow with Siemens circuit breakers.

Busway ultimate temperature rise value - Wiener Busway ultimate temperature rise value - Wiener

The ultimate temperature value-added of the busway is directly related to the current-carrying capacity of the conductor and the potential safety hazards, so it is necessary to mark the limiting temperature value-added of the busway, which is the most critical safety technical parameter of the busway. Follow me...

Busbar system segmentation understanding - Wiener Busbar system segmentation understanding - Wiener

The so-called "section" of the bus bar is that the data that constitutes the bus are directly connected, and there is no circuit breaker or blocking switch in the center. A circuit breaker or barrier switch in the center is called a "segment". Different voltage levels cannot be connected in the same section. No...

Characteristics of single bus wiring in the switchgear - Wiener Characteristics of single bus wiring in the switchgear - Wiener

In power distribution equipment such as voltage distribution cabinets and switchgear at all levels of power plants and substations, the conductors connected between large electrical equipment such as generators and transformers and various electrical equipment are called busbars. Busbars, also known as busbars, are used to gather, distribute, and transmit electrical energy. The connection methods of the bus bar are ...

Precautions for installation of Wiener busway Precautions for installation of Wiener busway

1. Before the bus duct installation, it should be ensured that the electrical shaft, substation and distribution room, the decoration project of the place through which the bus duct passes, and the heating and ventilation project are all completed to ensure that the bus duct is not polluted. The reserved holes and embedded parts of the floor and wall should be embedded and reserved according to the position required by the design. The functions of the busway are single ...

Distribution cabinet bus calculation method - Vilna Distribution cabinet bus calculation method - Vilna

1. The main bus at the upper end of the low-voltage distribution cabinet is calculated according to the material and cross-section in the extension meter. The bus bar connected to the main bus at the upper end of the switch is not accounted for and is included in the low-voltage distribution cabinet. 2. The transformer mainly depends on how large the load is, according to your switchgear can be calculated to match the transformer, but not the same...

A detailed description of the Wiener comb busbar and connection terminals A detailed description of the Wiener comb busbar and connection terminals

The Wiener comb busbars and connection terminals are available with QUADRON®CrossLinkBreaker in size 000/00 Recommended installation: Wire entry at the lower end of the NH-fuse disconnector through the comb busbar. In the mounting position ...

Wiener looks at the busway drawing method Wiener looks at the busway drawing method

First, in the CAD system drawing, it is a plan of the bus duct, and two parallel polylines can indicate the bus duct. 2. The busway includes the following parts: 1. Feeder busbar, which is used to transmit electricity 2. Plug-in busbar with plug-in interface above, ...

Detailed explanation of Wiener DC bus Detailed explanation of Wiener DC bus

1. Three-phase AC power supply inlet The power input of each inverter is connected in parallel on the same AC bus, and the power phase of the input end of each inverter is ensured. The circuit breaker QF is the incoming line protection device for each inverter. LR is an incoming reactor, when multiple inverters are operating in the same environment.

Busbar system in detail – Vernal Busbar system in detail – Vernal

1. In the 60mm bus system, the square fuse type blocking switch can be directly hooked. 2. The 60mm bus system refers to the three-wire or four-wire bus spacing of 60mm. 3. Strip NH-fuse type load barrier switch with scale 00 ...

How to optimize the busbar system of the computer room - Wiener How to optimize the busbar system of the computer room - Wiener

In today's information society, the computer room is a very common equipment, so the most important thing in a computer room is the bus system, which is the center and skeleton of the power distribution of the entire computer room. Then a reasonable bus system will greatly improve the efficiency of the equipment room. So how do you optimize ...

Classification of the use of different places in the busway - Vernal Classification of the use of different places in the busway - Vernal

(1) General bus duct Non-flame retardant and non-fire-resistant bus duct used in general load power distribution. In the event of a fire during a short circuit, it will always incinerate to other connected busbars, which may briefly cause fire accidents. (2) Flame retardant bus duct ...

What is the role of the busbar in the distribution box What is the role of the busbar in the distribution box

Busbar refers to a product made of copper and aluminum materials with high conductivity to transmit electrical energy and have the ability to gather and distribute electricity. The main conductor used by the power station or substation to transport electrical energy. In the power system, the busbar in the distribution box connects the various current-carrying branch circuits in the distribution unit, ...

Wiener Electric's busbar system escorts the operation of textile machinery equipment Wiener Electric's busbar system escorts the operation of textile machinery equipment

According to Wiener electrical engineer, the bus system is a process-assisted component, the main effect is to hook the switch on the adapter, and the adapter is then hooked on the copper bar, so that the full protection of the copper bar can be completed, and the safety factor is improved; The upper port of the switch can be connected without ...

Application advantages of industrial busway - Wiener Application advantages of industrial busway - Wiener

1. It has a modern beauty; 2. Small dimensions; 3. Strong and light weight, simple operation; 4. The connection is very simple (just like connecting water pipes, connecting sections through tees, elbows and other joints to make them into a system; ...

Wiener busway specification standard parameters Wiener busway specification standard parameters

1. The standard scale of the bus duct This specification regulates the terminology, skill requirements and test methods of the insulated bus trunk system (bus duct) and its plug-in feed box (hereinafter referred to as the feed box). This specification specification applies to additional voltage AC to 660V...

Wiener busway plug-in box wiring method Wiener busway plug-in box wiring method

The bus duct bracket has to be firmly installed, and the bus duct should be correctly placed according to the segment sequence number, phase sequence, number, direction and device mark, and when the sections are connected, the adjacent section of the bus duct should be aligned, and the conductor and shell of the bus duct should not accept mechanical stress after the connection. ...

Advantages of busbar mounted electrical equipment - Wiener Advantages of busbar mounted electrical equipment - Wiener

The novelty, flexibility and originality of the busbar device appliance. It indicates the vitality of this skill and its broad market prospects. This is the real reason for our attention. First of all, this small electrical appliance plant was conceived ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top