(1) General bus duct

Non-flame retardant and non-fire-resistant bus duct used in general load power distribution. In the event of a fire during a short circuit, it will always incinerate to other connected busbars, which may briefly cause fire accidents.

                            Classification of the use of different places in the busway - Vernal

(2) Flame retardant bus duct

In the event of a fire, the flame of this section of the bus will not extend to the bus duct of the other section. To put it simply, the coating of the metal shell of the bus duct and the insulation material of the bus bar must be flame retardant.

(3) Refractory busway

A busway that maintains the integrity of the circuit for a specified period of time under flame conditions. The insulation materials of the fire-resistant busway are conventionally non-combustible materials, and flame-retardant materials are also used. However, it is necessary to carry out type tests according to the national standard JB/T10327-2011 "Refractory Bus Trunk System (Refractory Bus Duct)" to verify its electrical functions such as fire prevention and fire resistance functions, and ensure that it can supply power normally within the specified time in the fire environment.

More on that
The operation procedure of the dual power supply automatic transfer switch The operation procedure of the dual power supply automatic transfer switch

The dual-supply ACT is a new generation of products. Beautiful appearance, good quality, long life, simple It is composed of two three-pole or four-pole shell graders and their parts/mechanical interlocking transmission arrangements, intelligent controllers, etc., which are divided into two structures: integral and split.

Development of the busbar trunk system – Wiener Development of the busbar trunk system – Wiener

(1) Air-type busway Since the mid-50s of the last century, represented by Beijing Baizhifang Airport Electrical Appliance Factory, the conductive row has been supported in the shell with insulating liner and insulated by air medium. The phase-to-phase distance is 50mm. (2) Secret ...

Introduction of busbar, busway and busway bridge - Vernal Introduction of busbar, busway and busway bridge - Vernal

generatrix In the field of electricity, the busbar can also be called the busbar, busbar, etc., most of which refer to the busbar or power supply trunk in the high and low voltage cabinet, which is used to connect multiple electrical lines. The system will install various interface cards through the bus, and transmit various data to the devices connected to the interface cards.

Busway installation waterproofing work - Vernal Busway installation waterproofing work - Vernal

Most of the bus duct is the design standard for indoor use, so even if the humidity in the indoor air is relatively high, it will not have much impact on the operation of the busbar, but the bus duct enters the water during the use of the busway, which will definitely cause a certain degree of impact.

Wiener busbar system PT disconnection treatment Wiener busbar system PT disconnection treatment

The judgment of PT three-phase voltage loss (symmetrical disconnection) is fundamentally the same for each manufacturer, and it is judged according to the three-phase no voltage and the current of the line. The same is true for PT asymmetrical wire breakage. After analyzing the characteristics of PT wire breaking, the specific judgment of PT asymmetric wire breaking of different manufacturers ...

Bus voltage non-system equipment failure and solution - Wienal Bus voltage non-system equipment failure and solution - Wienal

In order to ensure the safe and economical operation of the power system and its power generation, supply and electrical equipment, power grid users require the voltage to operate in three ways: forward voltage regulation, reverse voltage regulation and constant voltage regulation. However, when the power grid is in practice, due to the change of active and reactive power output, the increase or decrease of electricity load, and the system wiring party...

Precautions for busway installation Precautions for busway installation

1. Requirements for civil engineering before installation 1. The foundation, frame, reserved holes and embedded parts meet the planning requirements of electrical equipment. 2. After the construction of the roof and floor slab, there shall be no leakage. 3. After the indoor above-ground construction is completed, mark the leveling elevation on the wall on the ground.

The importance of room power supply and busbar system – Vernal The importance of room power supply and busbar system – Vernal

In today's information society, the computer room is a very common equipment, so the most important thing in a computer room is the bus system, which is the center and skeleton of the power distribution of the entire computer room. Then a reasonable bus system will greatly improve the efficiency of the computer room. So how do you optimize ...

Advantages of installing cable trays with busway – Wiener Advantages of installing cable trays with busway – Wiener

When it comes to cable tray installation, wiring is not very convenient. This phenomenon can be avoided by using busway. The 5 advantages of using busway in the cable tray device are as follows: 1. Convenient connection of bus duct: the so-called plug-in bus duct, fireproof bridge is the way it uses plugged in.

Busway installation method - Wiener Busway installation method - Wiener

1. Busway horizontal device, the interval between the two brackets is ≯2500mm, and the interval between straight devices is ≯3600mm; 2. When the device bracket is straight, it should be drilled with the channel side plate and fastened with M6-M8 bolts. 3. In the process of installation construction, priority should be given to the power supply system, ...

How to choose the right fuse - Wiener How to choose the right fuse - Wiener

1. Select the type of fuse according to the line requirements and installation conditions. Circuits with small capacity are semi-enclosed or enclosed without fillers; The selection of large short-circuit current has a packing closed type; Semiconductor component maintenance selection of quick fuses. ...

Busway installation method - Wiener Busway installation method - Wiener

1. Busway horizontal device, the interval between the two brackets is ≯2500mm, and the interval between straight devices is ≯3600mm; 2. When the device bracket is straight, it should be drilled with the channel side plate and fastened with M6-M8 bolts. 3. In the process of installation construction, priority should be given to the power supply system, ...

Introduction to Laminated Busbar System – Wiener Introduction to Laminated Busbar System – Wiener

In the power system, the bus connects the various current-carrying branch circuits in the power distribution device together, and plays the role of collecting, distributing and transmitting electric energy; According to the appearance and structure, the bus bar is roughly divided into three categories: hard busbar, soft busbar and closed busbar. ...

Advantages of pluggable busway Advantages of pluggable busway

1. The plug-in bus duct has strong overload capacity The overload capacity of the bus duct is strong, depending on the high working temperature of the insulation material it uses, and the working temperature of 105 is selected for the insulation data used in the bus duct, and the radiation cross-linked flame retardant winding tape with a working temperature of more than 140 °C has been developed.

Advantages of cable tray installed in busway Advantages of cable tray installed in busway

At the time of the cable tray installation, the wiring is not very convenient. This phenomenon can be avoided by using busway. The 5 advantages of using busway in the cable tray device are as follows: 1. Convenient connection of bus duct: the so-called plugging ...

Fast protection of medium and low voltage busbars – Wienal Fast protection of medium and low voltage busbars – Wienal

1.It is necessary to install arc light maintenance Arc maintenance in foreign countries has nearly 20 years of history, the first set of maintenance devices in 1995 has been put into operation, China's previous imported units in the introduction of foreign complete sets of arc light maintenance (such as Guohua Tianjin Panshan Power Plant), domestic units ...

Rectangular busbar, trough busbar, and tubular busbar analysis Rectangular busbar, trough busbar, and tubular busbar analysis

The rectangular bus has good heat dissipation performance and is easy to fix and connect. But its skin effect is quite large. In order to reduce the skin effect, the cross-sectional area of a single busbar should not exceed 1250 square millimeters. When the working current exceeds the promised current of a single bus, 2 to 4 rectangular buses can be used. Rectangular conductor a ...

Lighting power busway service life - Wienal Lighting power busway service life - Wienal

The system consists of a current box, a bus body, a branch plug and device accessories. When the heat dissipation of conductive copper strip has been effectively improved, the contact between the copper strip and the inner wall of the tube is reduced, and the insulation resistance and anti-aging ability of the tube body are strengthened, so as to prolong the service life of the pipe body. The life of the tube far exceeds ...

Wiener Electric's busbar system escorts the operation of textile machinery equipment Wiener Electric's busbar system escorts the operation of textile machinery equipment

According to Wiener electrical engineer, the bus system is a process-assisted component, the main effect is to hook the switch on the adapter, and the adapter is then hooked on the copper bar, so that the full protection of the copper bar can be completed, and the safety factor is improved; The upper port of the switch can be connected without ...

Classification of the use of busway in different places - Vernal Classification of the use of busway in different places - Vernal

(1) General bus duct Non-flame retardant and non-fire-resistant bus duct selected for general load power distribution. In the event of a short circuit, it will be incinerated until it is connected to other busbars, which can easily cause fire accidents. (2) Flame retardant bus duct ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top