Busbar refers to a product made of copper and aluminum materials with high conductivity to transmit electrical energy and have the ability to gather and distribute electricity. The main conductor used by the power station or substation to transport electrical energy. In the power system, the bus in the distribution box connects the various current-carrying branch circuits in the distribution device and plays the role of gathering, distributing and transmitting electrical energy.
In the distribution box, the bus bar is made of copper or aluminum bar, which has high current density, small resistance, small skin effect, and no need to reduce capacity. Small power buck also means low energy loss, which ultimately saves the user's capital. The core of the cable is a multi-strand thin copper wire, and its root area is larger than that of the bus bar of the same current level. And its "skin effect" is serious, which reduces the current rating, increases the voltage drop, and is easy to heat. The metal-enclosed housing of the busway can maintain the busbar from mechanical damage or animal injury, improving the safety of the distribution box.
|
More on that
|
Advantages of a shared DC bus system – Wienal
The shared DC bus system is the future development direction in the application of multi-drive motors, which makes reasonable use of the regenerative energy of the system together with better dynamic and static functions and speed regulation accuracy, eliminating a lot of braking units and braking resistors, and the energy efficiency ratio of the system has been greatly improved.
|
|
Advantages of busbar mounted electrical equipment - Wiener
The novelty, flexibility and originality of the busbar device appliance. It indicates the vitality of this skill and its broad market prospects. This is the real reason for our attention.
First of all, this small electrical appliance plant was conceived ...
|
|
Busbar system reverse operation – Wiener
1. For the charging of the spare bus, when there is a bus tie circuit breaker, the bus tie circuit breaker should be used to charge the spare bus. At this moment, the maintenance device of the bus tie circuit breaker should be fully invested, and the relevant maintenance value and time limit should be changed to a smaller one, so as to facilitate the bus tie circuit breaker when there is a problem, the bus tie circuit breaker can quickly trip, cut ...
|
|
The connection method of the tubular busbar
In the industry, tubular bus bar can be described as one of the more common equipment, with high mechanical strength, good insulation, wide range of application and other characteristics of many enterprises. So do you know what are the ways to link tubular busbars?
...
|
|
Temperature rise requirements and safety of Wiener busway
With the rapid development of our economy and technology, the trend of urbanization is becoming more and more popular, and people's electricity consumption is also increasing. In this case, the busway has developed significantly, and the use of instead of cable has become the development trend of the times. Therefore, what are the requirements for the temperature rise of the busway and ...
|
|
Precautions for the operation of low-voltage cabinets - Wienal
1. To carry out work in all and part of the energized panels, the equipment should be overhauled and separated from the operating machinery and equipment with obvious markings.
2. The secondary winding of the voltage transformer and the transformer should have reliable grounding maintenance.
3. On the secondary circuit of the voltage transformer in operation...
|
|
What are the hazards of 220V DC in the bus system - Wiener
The grounding of the DC system should include two situations: the one-point grounding of the DC system and the two-point grounding of the DC system.
In the DC system, the positive and negative poles of DC are insulated from the ground, and there is no grounding current when generating a ground current when one pole is grounded.
|
|
Laminated busbar system – Wiener
In the power system, the bus connects the various current-carrying branch circuits in the power distribution device together, and plays the role of collecting, distributing and transmitting electric energy; According to the appearance and structure, the bus bar is roughly divided into three categories: hard busbar, soft busbar and closed busbar.
...
|
|
Mesh tray reduces the cost of replacing cables – Wiener
(1) Simple maintenance and repair operations
Equipment is often added or removed or changed in the computer room, and cables are removed or added at the same time, and the grid bridge with open structure can observe the cables to the maximum extent, so it is easy to distinguish the cables that need to be replaced, so that maintenance and repair ...
|
|
Types of corrosion of Wiener tubular busbars
Tubular bus is a new type of equipment that is widely used in our current days, and it itself has the characteristics of high current, outstanding insulation and wide range of application, so we don't seem to be too worried about its function and role when using it. But there is one thing that needs to be ...
|
|
What are the characteristics of the bus wiring method of the power system?
(1) Single bus wiring. Single bus wiring has the advantages of simplicity and clarity, less equipment, less investment, and convenient operation and expansion, but its reliability and activity are poor. When the bus or bus separator is faulty or overhauled, all power to the bus must be disconnected.
...
|
|
Introduction to the classification of busway - Wiener
According to the different uses of the bus duct, the bus groove is generally composed of the start bus slot, the straight bus slot (no partition jack and jack), the L-shaped straight (horizontal) curve bus, the Z-type straight (horizontal) offset bus, the T-shaped straight (horizontal) tee bus, the X-type straight (horizontal) cross-way bus, the variable ...
|
|
Use and characteristics of AC busbar systems – Wiener
The communication and connection skills of the independent power supply system create better prospects for the power supply of the future. Hundreds of systems around the world have installed SMA's Sunny Island battery inverters to supply power to customers for a long time. The stackability of Sunny Island, i.e. multiple Sunny Islands ...
|
|
Phase of the busway in the low-voltage incoming line – Wiener
According to the requirements of the relevant specifications, the placement of the three-phase busbar can be roughly divided into two kinds according to the model of the low-voltage distribution cabinet and the different manufacturers: horizontal placement and placement of the down wire, according to the order of placement.
|
|
Wiener Data Center Bus System
Although the service life cost of the busbar system is usually lower than that of the traditional wiring method, the busbar system still bears a considerable cost compared to other structural elements of the water supply and drainage or HVAC system.
In addition, customized busbars ...
|
|
Introduction to the advantages of busway - Wiener
The advantage of the busway is that its structural design is simple, it is composed of metal plates, which can connect the circuits together, so as to achieve the safe and reliable transmission of electric energy. In addition, its structural design can effectively assist in reducing the occurrence of short circuits, reducing heat loss, and can effectively ensure the power ...
|
|
The essence of Wiener busbar technology
1. Closed busbar hooking technology
Circuit breakers and contactors can be hooked on the bus through the bus adapter, and fuse switches and other products are directly attached to the bus, so the bus bar plays a two-layer effect of conductive and fixed rotation.
|
|
Precautions for terminal block wiring - Wiener
1. The fastening wiring force should be moderate, avoid sliding the bolts and nuts with excessive force, and replace the bolts and nuts that have been slid in time, and prohibit the operation.
2. When tightening or loosening the screws with a screwdriver, it is necessary to force the screws to ...
|
|
Difference Between Busbar and Busway – Vernal
The connection of voltage distribution devices at all levels in the substation, as well as the connection of electrical equipment such as transformers and corresponding distribution devices, mostly use bare wires or stranded wires of rectangular or circular cross-section, which are collectively referred to as busbars.
The role of the bus bar is to collect, distribute and transmit electrical energy. Because the busbar ...
|
|
Wiener Electric's busbar system escorts the operation of textile machinery equipment
According to Wiener electrical engineer, the bus system is a process-assisted component, the main effect is to hook the switch on the adapter, and the adapter is then hooked on the copper bar, so that the full protection of the copper bar can be completed, and the safety factor is improved; The upper port of the switch can be connected without ...
|
|