A detailed description of the Wiener comb busbar and connection terminals

Create Date: 2024-8-30 12:03:23|Source: Woehner/Wiehner

The Wiener comb busbars and connection terminals are available with QUADRON®CrossLinkBreaker in size 000/00
                                  A detailed description of the Wiener comb busbar and connection terminals
Recommended installation: Wire entry at the lower end of the NH-fuse disconnector through the comb busbar.

When there is a deviation between the installation position and the installation conditions, pay attention to the use of capacity reduction.

Degree of protection: IP20 The front can be combined with NH-fuse type disconnectors, comb busbars and connection terminals.

The degree of protection of the terminal depends on the installation method.

Touch protection: according to EN 50274/BGV A3.

Rated operating voltage: 690 V AC/440 V DC.

Rated insulation voltage: 800V when the pollution level is 2;

At a pollution level of 3, 690 V.

Rated impulse withstand voltage: 6 kV.

Rated impulse withstand current: 25 kA/400 V.

Rated short-circuit current stability: 12.5 kA-100 ms/400 V.

Size 000: Connection terminal: Cu 6 - 35 mm2 re, rm; Cu 4 - 25 f, f+AE

(maximum connection diameter 11 mm).

Cross-sectional area of comb busbar: 35 mm2.

Size 00: Connection terminal: Cu 25 - 95 mm2 re, rm; Cu 35 - 95 mm2 sm ; Cu 25 - 70 mm2 f+AE

(Pressed into a square or trapezoidal shape with a maximum connection diameter of 14 mm).

Current rating: Intermediate input 1 x 260 A / 2 x 260 A; Side input 1 x 130 A
More on that
Protection of medium and low voltage busbars – Wienal Protection of medium and low voltage busbars – Wienal

There are three types of maintenance commonly used in medium and low voltage bus systems: (1) Transformer backup overcurrent maintenance (typical maintenance action time is 1.2s - 1.4s) (2) Transformer voltage with feeder quick-break maintenance locking ...

How to choose the right fuse - Wiener How to choose the right fuse - Wiener

1. Select the type of fuse according to the line requirements and installation conditions. Circuits with small capacity are semi-enclosed or enclosed without fillers; The selection of large short-circuit current has a packing closed type; Semiconductor component maintenance selection of quick fuses. ...

Wiener fixed and busbar mounting Wiener fixed and busbar mounting

Precautions for the device VDE 0660 Specification Section 107 / EN 60947-3 Specification / IEC 60947-3 Specification 3 poles are broken at the same time, double breakpoints. Operator-independent, safe opening/closing, in position ...

The application of Wiener bus system wiring technology in box transformer The application of Wiener bus system wiring technology in box transformer

The bus system is to directly connect the components to the bus, the bus does not need to be perforated, at this time, the bus is not only the conductor of the component, but also the support of the component, the current can reach 2500A, so that the box transformer function has the following progress: 1 ...

Distribution cabinet bus connection method - Wiener Distribution cabinet bus connection method - Wiener

When users use the distribution cabinet, they must understand the circuit device of the busbar, and many users are not very well understood, so let's talk about the bus connection mode of the distribution cabinet. The bus bar is used for the internal and external electrical appliances of the distribution cabinet.

Difference Between Fuse and Circuit Breaker – Vernal Difference Between Fuse and Circuit Breaker – Vernal

The principle of the fuse is to use the current to flow through the conductor to heat the conductor, and the conductor is ablated after reaching the melting point of the conductor, so the electrical appliances and circuits used for circuit maintenance are not burned out. It is an accumulation of heat, so it is also able to complete overload maintenance. Once...

Application advantages of industrial busway - Wiener Application advantages of industrial busway - Wiener

1. It has a modern beauty; 2. Small dimensions; 3. Strong and light weight, simple operation; 4. The connection is very simple (just like connecting water pipes, connecting sections through tees, elbows and other joints to make them into a system; ...

Precautions for busway installation Precautions for busway installation

1. Requirements for civil engineering before installation 1. The foundation, frame, reserved holes and embedded parts meet the planning requirements of electrical equipment. 2. After the construction of the roof and floor slab, there shall be no leakage. 3. After the indoor above-ground construction is completed, mark the leveling elevation on the wall on the ground.

Precautions for terminal block wiring - Wiener Precautions for terminal block wiring - Wiener

1. The fastening wiring force should be moderate, avoid sliding the bolts and nuts with excessive force, and replace the bolts and nuts that have been slid in time, and prohibit the operation. 2. When tightening or loosening the screws with a screwdriver, it is necessary to force the screws to ...

Tubular busbar structure layout - Wienal Tubular busbar structure layout - Wienal

1. The tubular bus is in the form of a split-phase fully insulated shielded copper tube bus. 2. The cylindrical capacitor structure is selected, and the voltage equalizing capacitor layer, the main insulation layer, and the bottom layer of the shielding street are set between the conductor and the insulating sheath, and the shielding grounding layer on the outside is connected to the grounding grid. The quantity of each layer is determined by the seller.

Low-voltage enclosed busway function - Wiener Low-voltage enclosed busway function - Wiener

Phase-off bus is a kind of high-current transmission equipment widely used in the outgoing circuit of generators of 50MW and above and the branch circuit of the factory The phase-off busbar, conductor and shell are made of aluminum plate coil and welding, with the following characteristics: ...

The difference between metal busbar and closed busbar - EVOC The difference between metal busbar and closed busbar - EVOC

The nature is different Busbar: It is a common path on which multiple devices are connected in the form of side-by-side branches. Busway: It is a closed metal equipment composed of copper and aluminum busbars. Different uses Mother...

Characteristics of power system bus wiring mode Characteristics of power system bus wiring mode

(1) Single bus wiring. Single bus wiring has the advantages of simple and clear, less equipment, less investment, convenient operation and expansion, but its reliability and activity are poor. When the bus or bus divider is faulty or overhauled, it is necessary to disconnect all power to the bus. ...

Conductor and bus welding requirements - Wiener Conductor and bus welding requirements - Wiener

1. Before welding, it is necessary to check whether the welding equipment is defective, whether the grounding of the electrical equipment is reliable, and strictly abide by the "welder safety operation procedures" when welding. 2. Correct wires and busbars, and prohibit the use of handleless files. ...

Standard parameters of busway specification - Wiener Standard parameters of busway specification - Wiener

1. The standard scale of the bus duct This specification regulates the terminology, skill requirements and test methods of the insulated bus trunk system (bus duct) and its plug-in feed box (hereinafter referred to as the feed box). This specification specification applies to additional voltage AC to 660V...

Features of the use of closed busway - Wiener Features of the use of closed busway - Wiener

Compared with other air-type busway, Wiener closed busway has many similarities in appearance, and its difference lies mainly in the shell, the structure of the closed busway is more distinctive, which also makes its use have certain advantages. As long as it is in contrast ...

Development of the busbar trunk system – Wiener Development of the busbar trunk system – Wiener

(1) Air-type busway Since the mid-50s of the last century, represented by Beijing Baizhifang Airport Electrical Appliance Factory, the conductive row has been supported in the shell with insulating liner and insulated by air medium. The phase-to-phase distance is 50mm. (2) Secret ...

Use and characteristics of AC busbar systems – Wiener Use and characteristics of AC busbar systems – Wiener

The communication and connection skills of the independent power supply system create better prospects for the power supply of the future. Hundreds of systems around the world have installed SMA's Sunny Island battery inverters to supply power to customers for a long time. The stackability of Sunny Island, i.e. multiple Sunny Islands ...

The busway power system is a key component - Wiener The busway power system is a key component - Wiener

The busway is one of the more critical components in the power system, and it is an important part of connecting cables to important equipment such as substations, overhead lines, transformers, circuit breakers, etc. It is widely used in various power systems, mainly for the reliable operation of power systems. ...

What is tubular busbar and dense busbar - Wiener What is tubular busbar and dense busbar - Wiener

What is a tubular busbar Tubular bus bar is a kind of bus bar product with copper tube or aluminum alloy tube as conductor and external insulation. The tubular bus has the characteristics of high current (12000A), high mechanical strength, good insulation, wide application range, etc., ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top