Busbar system in detail – Vernal

Create Date: 2024-8-30 12:03:23|Source: Woehner/Wiehner

1. In the 60mm bus system, the square fuse type blocking switch can be directly hooked.

                               Busbar system in detail – Vernal

2. The 60mm bus system refers to the three-wire or four-wire bus spacing of 60mm.

3. The 00 bar NH-fuse load barrier switch can be used with all components on the 60mm bus system.

4. In the 60mm bus system, the different cross-sectional areas of rectangular copper bars or special-shaped copper busbars such as 2T and 3T can be used to complete the optimal distribution of current intensity grades, with high safety and reliability.

5. The combination of feet and the patented mechanical card slot ensure that the strip NH-fuse load blocking switch is quickly installed on the non-punching busbar. You can change the upper or lower end of the line in and out.

6. The NH-fuse type load blocking switch (bus type) with a scale of 000-3 can be converted from the upper end and the lower end. The elastic touch plate can complete a simple and safe touch with the bus system.

7. New 60mm bus system transfer skills: the switch can be safely hooked on 12×5mm-30×10mm, double T or triple T bus through the bus adapter, and the maximum current of the system is 2500A. There is no need to cut off the power when the switching element is replaced.

8. On the 60mm bus system, 3-phase strip D0- and D- fuse headers (bus type) can be installed. NH- Fuse holder with touch maintenance (busbar type) The maximum size is 2. Special NH-fuse holders are fitted with fast-acting fuses to maintain semiconductor components.

9. The general wire connection clamp or wiring board can connect the maximum 300mm2 wire on the non-punched busbar, and the wiring board can be used to connect the two bus systems without cutting off the wire. The unfolding adapter uses ultra-strong snapping skills to quickly connect round and flat wires. The bus extension adapter can safely and conveniently complete the expansion of the bus system between cabinets.
More on that
Busbar system reverse operation – Wiener Busbar system reverse operation – Wiener

(1) For the charging of the spare bus, when there is a bus tie circuit breaker, the bus tie circuit breaker should be used to charge the spare bus. At this time, the maintenance device of the bus tie circuit breaker should be fully invested, and the relevant maintenance value and time limit should be changed to a small size, so that when there is a problem with the bus, the bus tie circuit breaker can be quickly tripped, cut off...

Mesh tray reduces the cost of replacing cables – Wiener Mesh tray reduces the cost of replacing cables – Wiener

(1) Simple maintenance and repair operations Equipment is often added or removed or changed in the computer room, and cables are removed or added at the same time, and the grid bridge with open structure can observe the cables to the maximum extent, so it is easy to distinguish the cables that need to be replaced, so that maintenance and repair ...

The application of Wiener bus system wiring technology in box transformer The application of Wiener bus system wiring technology in box transformer

The bus system is to directly connect the components to the bus, the bus does not need to be perforated, at this time, the bus is not only the conductor of the component, but also the support of the component, the current can reach 2500A, so that the box transformer function has the following progress: 1 ...

220V DC Hazard in Busbar System – Wiener 220V DC Hazard in Busbar System – Wiener

The grounding of the DC system should include two conditions: the one-point grounding of the DC system and the two-point grounding of the DC system. In the DC system, the positive and negative poles of DC are insulated from the ground, and they do not cause any harm when generating a ground current because there is no path to constitute a grounding current, but the ground of one pole is long.

How to choose the right busway products - Wiener How to choose the right busway products - Wiener

1. Selection of qualified products of regular enterprises: The busway must be a product with the 3C necessary certification mark and style test report. China's busway factories are uneven, and most of the production methods are handicraft, mainly in well-off areas. When purchasing, it is necessary to thoroughly investigate the production of the factory ...

Introduction to the advantages of busway - Wiener Introduction to the advantages of busway - Wiener

The advantage of the busway is that its structural design is simple, it is composed of metal plates, which can connect the circuits together, so as to achieve the safe and reliable transmission of electric energy. In addition, its structural design can effectively assist in reducing the occurrence of short circuits, reducing heat loss, and can effectively ensure the power ...

NH-Fuse Type Disconnector Instructions for Use NH-Fuse Type Disconnector Instructions for Use

When switching on and off components, you should pay attention to the following: –In accordance with VDE-0105-100, only operation by electrical professionals or persons with electrical knowledge is allowed (operation without electricity, closing, disconnecting, and replacing fuses ...).

Difference Between Busbar and Cable – Vernal Difference Between Busbar and Cable – Vernal

When the busway has not been developed and introduced, the cable is still an indispensable figure in the low-voltage distribution system, when the busway system is introduced and widely used. Whether to choose the cable or the bus duct has become a topic of endless debate. So it's hard to say which of the two is better ...

The role of plug-in busway – Wiener The role of plug-in busway – Wiener

Generally speaking, plug-in busway is mainly used for power transmission. We know that all conductors will have losses, and the losses caused by the flow of electricity through conductors are larger and some are smaller. For example, compared with the aluminum wire with the same wire diameter and the copper wire, the loss of aluminum is larger, and the loss of copper is smaller. That is, the conductivity ...

Cooling method for dense busway – Wiener Cooling method for dense busway – Wiener

If the temperature of the dense busway is too high, a fault will occur. For the sake of insurance, it is necessary to know the heat dissipation method of the densely packed busway to prevent the impact of excessive temperature on the busway. Low-voltage transmission line conductors, wires, cables, branch dense busway, exposed conductive poles, punctured ...

Advantages of cable tray installed in busway Advantages of cable tray installed in busway

At the time of the cable tray installation, the wiring is not very convenient. This phenomenon can be avoided by using busway. The 5 advantages of using busway in the cable tray device are as follows: 1. Convenient connection of bus duct: the so-called plugging ...

Introduction to Laminated Busbar System – Wiener Introduction to Laminated Busbar System – Wiener

In the power system, the bus connects the various current-carrying branch circuits in the power distribution device together, and plays the role of collecting, distributing and transmitting electric energy; According to the appearance and structure, the bus bar is roughly divided into three categories: hard busbar, soft busbar and closed busbar. ...

Introduction to the components of the busway - Vernal Introduction to the components of the busway - Vernal

Busway is a conductive equipment used for current transmission, and now the higher the building is built, the more the application of busway is required, and in many large foremen, the use of busway is also very economical and reasonable. Any machine is made up of different parts, then the busway is made up of ...

Bus voltage non-system equipment fault handling method - Wiener Bus voltage non-system equipment fault handling method - Wiener

In order to ensure the safe and economical operation of the power system and its power generation, supply and electrical equipment, power grid users require voltage separation to operate in three ways: forward voltage regulation, reverse voltage regulation and constant voltage regulation. However, in the actual operation of the power grid, due to the change of active and reactive power output, the increase or decrease of the electrical load, the system wiring party...

Knowledge points of Wiener busway Knowledge points of Wiener busway

Busway was born in the United States, first put into practical use in Japan, and then spread all over the mountains and regions in prosperous countries and regions. So what is a busway? Busway is a high-current trunk tappable power supply system, usually made of a metal housing (iron or aluminum).

Analysis of the conditions for the use of sealed busbars - Wienal Analysis of the conditions for the use of sealed busbars - Wienal

Ambient air temperature: turn off the busbar system to benchmark the ambient air temperature; Unless otherwise ruled, the manufacturer should give an additional current to shut down the busbar system at a base ambient air temperature of 35°C; If applicable, the manufacturer should give an additional coefficient k: (K1=1 at 35°C) in order to determine the size of the package.

Comparison of several insulated tubular busbars Comparison of several insulated tubular busbars

The use of insulated tube bus in China has a history of nearly 20 years, and it has made a historic contribution to reducing the layout space of the distribution bus and improving the reliability of the bus operation. There are many manufacturers who supply this product, and their production processes are uneven, and the differences in processes are mainly reflected in the ...

Busbar system segmentation understanding - Wiener Busbar system segmentation understanding - Wiener

The so-called "section" of the bus bar is that the data that constitutes the bus are directly connected, and there is no circuit breaker or blocking switch in the center. A circuit breaker or barrier switch in the center is called a "segment". Different voltage levels cannot be connected in the same section. No...

Low-voltage dense busway uses and applications Low-voltage dense busway uses and applications

Densely insulated bus duct (hereinafter referred to as bus duct) can be communication three-phase three-wire, three-phase four-wire, three-phase five-wire system, frequency 50-60Hz, voltage to 400V, rated operating current of 250-5000A, mainly as a new type of power supply and distribution equipment in industrial and mining, enterprises and high-rise buildings. Mother with insertion day ...

Bus voltage non-system equipment failure and solution - Wienal Bus voltage non-system equipment failure and solution - Wienal

In order to ensure the safe and economical operation of the power system and its power generation, supply and electrical equipment, power grid users require the voltage to operate in three ways: forward voltage regulation, reverse voltage regulation and constant voltage regulation. However, when the power grid is in practice, due to the change of active and reactive power output, the increase or decrease of electricity load, and the system wiring party...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top