Wiener busway specification standard parameters
1. The standard scale of the bus duct
This specification regulates the terminology, skill requirements and test methods of the insulated bus trunk system (bus duct) and its plug-in feed box (hereinafter referred to as the feed box).
This specification specification applies to additional voltage AC to 660V...
|
|
Dense busbar installation – Wiener
1. Requirements for civil engineering before installation
1) The foundation, structure, reserved holes and embedded parts all meet the design requirements of electrical equipment.
2) After the construction of the roof and floor slab is completed, there shall be no leakage.
3) After the indoor ground construction is completed, mark the ground leveling line on the well wall.
...
|
|
Comparison of several insulated tubular busbars
The use of insulated tube bus in China has a history of nearly 20 years, and it has made a historic contribution to reducing the layout space of the distribution bus and improving the reliability of the bus operation. There are many manufacturers who supply this product, and their production processes are uneven, and the differences in processes are mainly reflected in the ...
|
|
Busway installation method - Wiener
1. Busway horizontal device, the interval between the two brackets is ≯2500mm, and the interval between straight devices is ≯3600mm;
2. When the device bracket is straight, it should be drilled with the channel side plate and fastened with M6-M8 bolts.
3. In the process of installation construction, priority should be given to the power supply system, ...
|
|
Performance characteristics of low-voltage busbar system - Wienal
Introduction to the performance of low-voltage bus system:
1. The bus bar is not perforated, and is connected with the cable and copper bar through the connection clip or terminal
2. Switches, contactors and other electrical components can be directly hung on the bus through adapters
3. Save ...
|
|
Closed busway essentials – Wiener
Before the closed busway device, it should be ensured that the electrical shaft, the transformer and distribution room, the decoration project of the place through which the busway passes, and the heating and ventilation project are all completed to ensure that the closed busway is not polluted. The reserved holes and embedded parts of the floor and wall should be embedded and reserved according to the position required by the design.
...
|
|
The use of busbar systems – Wiener busbars
First, this kind of small electrical equipment is a novel concept, adopting the "non-hole lap technology", and the electrical equipment is directly installed on the confluence bus system to form a power distribution or control loop. The representative creations are busbar device fuses and fuse load disconnectors.
...
|
|
Analysis of the product characteristics of Wiener busway
Since the busway is made of copper bars or aluminum as conductors, it has a large current capacity and good electrical and mechanical properties. In addition, it is made of a metal trough as the shell, so it is non-flammable, safe and reliable, and has a long service life. Compared with traditional power distribution or ...
|
|
Precautions for busway installation
1. Requirements for civil engineering before installation
1. The foundation, frame, reserved holes and embedded parts meet the planning requirements of electrical equipment.
2. After the construction of the roof and floor slab, there shall be no leakage.
3. After the indoor above-ground construction is completed, mark the leveling elevation on the wall on the ground.
|
|
Phase of the busway in the low-voltage incoming line – Wiener
According to the requirements of the relevant specifications, the placement of the three-phase busbar can be roughly divided into two kinds according to the model of the low-voltage distribution cabinet and the different manufacturers: horizontal placement and placement of the down wire, according to the order of placement.
|
|
The service life of the lighting power busway – Wienal
The system consists of a current box, a bus body, a branch plug and device accessories.
When the heat dissipation of conductive copper strip is effectively improved, the contact between the copper strip and the inner wall of the tube is reduced, the insulation resistance and anti-aging ability of the tube body are strengthened, and then the service life of the tube body is extended. The longevity of the tube far exceeds ...
|
|
Difference Between Grounding Electrode and Grounding Busbar – Vernal
The grounding electrode is a discharge channel that connects current or voltage to the earth, and in order to reduce the grounding resistance, the electrodes that form the grounding grid are generally used in groups.
The grounding bus refers to the connecting wire that connects the current or voltage to the grounding grid, or the conductor that connects the grounding electrode into one.
...
|
|
Calculation method of bus system and distribution cabinet bus - Wiener
The bus system divides the bus into hard bus and soft bus. The 60mm bus system refers to the three-wire or four-wire bus with a distance of 60mm.
1. In the 60mm bus system, the different cross-sectional areas of rectangular copper bars or special-shaped copper busbars such as 2T and 3T can be used to achieve the best classification of current intensity grades.
|
|
Uses and characteristics of detached closed busbar - Wiener
Closing busbars include out-of-phase shut-off buss, co-box (including co-box phase isolation) shut-off busbars and cable busbars, which are used for power plants, substations, industrial and civil power supply leads.
Phase-off busbar
1. Usefulness
Out of phase ...
|
|
The technology of the main bus bar in the low-voltage open light cabinet - Winer
One of the characteristics of the Wiener low-voltage switchgear is the multi-functional busbar system. The bus bar is a conductor that connects large electrical equipment such as generators and transformers with various electrical devices. The role of the bus bar is to transmit electric energy with the, and the bus bar is the main equipment constituting the electrical wiring. ...
|
|
Application of busway – Wiener
The busway system is an efficient power distribution device, especially suitable for the needs of high-rise buildings and large-scale factories for reasonable wiring. With the presentation of modern engineering equipment and equipment, the electricity consumption of all walks of life has increased rapidly, especially many high-rise buildings and large factories. Traditional cables serve as ...
|
|
Advantages and disadvantages of bus full differential protection
Thorough differential maintenance of the bus is to connect the current transformer of all the connecting elements on the bus to the differential circuit according to the same name phase and polarity, the characteristics and transformation ratio of the current transformer should be the same, if the transformation ratio can not be together, the compensation converter can be used to compensate, satisfactory ΣI=0.
...
|
|
The busway power system is a key component - Wiener
The busway is one of the more critical components in the power system, and it is an important part of connecting cables to important equipment such as substations, overhead lines, transformers, circuit breakers, etc. It is widely used in various power systems, mainly for the reliable operation of power systems.
...
|
|
How is the Wiener bus system generally debugged in sections?
Bus refers to the connection of voltage distribution devices at all levels in the substation, as well as the connection of electrical equipment such as transformers and corresponding distribution devices, most of which use bare wires or stranded wires with rectangular or circular sections. The role of the bus bar is to collect, distribute and transmit electrical energy. According to the structure, the bus bar is divided into hard busbar, soft ...
|
|
Difference Between Busbar and Busway – Vernal
The connection of voltage distribution devices at all levels in the substation, as well as the connection of electrical equipment such as transformers and corresponding distribution devices, mostly use bare wires or stranded wires of rectangular or circular cross-section, which are collectively referred to as busbars.
The role of the bus bar is to collect, distribute and transmit electrical energy. Because the busbar ...
|