In the hardware layout planning of the ship unloader distribution cabinet, in order to omit the wiring slot pawn, save time and effort in wiring, prevent wiring errors, and make the distribution cabinet beautiful and useful, the circuit breaker inlet end in the distribution cabinet will use the confluence method. The following are several commonly used confluence methods, taking Siemens circuit breaker 3RV, 5SJ, 3VL series circuit breaker as an example.
(1) The circuit breaker 3RV series is planned with a three-phase busbar and corresponding accessories, and the three-phase busbar will be connected to the circuit breaker with multiple screws connected side by side on the standard guide rail for feeding, insulation and finger touch safety protection, and is suitable for any short circuit conditions that may occur on the outlet side of the circuit breaker. The three-phase busbar device is finished, and a three-phase inlet terminal is connected to the upper circuit, the maximum wiring of the three-phase inlet terminal is 50mm², and the three-phase inlet terminal has a certain height, in order to make the line entering the three-phase inlet terminal not too short and cannot see the bushing number, the spacing between the wire ducts is required to take this height into account when layout.
(2) 5SJ single-pole to two-pole micro-disconnection is planned with busbar, one side/convergence feed load is 6sA/120A, single-phase and multi-phase model busbar is complete, and the wiring below 3smm² does not need to be attached to the inlet terminal, and can be directly connected to the inlet end of the circuit breaker.
(3) The distribution terminal is also called the high-current terminal, the use of the product for power distribution, one in and more out, there are a variety of standards, the use of fast, the product saves the planning of the stroke, for the single-phase module or three-phase module structure, the additional cross-section can be up to 240mm².
(4) The high-current conduction uses the copper bar busbar method, fixes two (or corresponding number) copper bars on the device board, the circuit breaker is installed on the guide rail or device board in the nearby direction, and the circuit breaker is connected to the copper bar, and the copper bar needs to be made according to the wire diameter and punching together with the demand to make an anti-electric shock protective cover, which is a commonly used high-current busbar mode before the emergence of the bus system.
|
More on that
|
Bus voltage non-system equipment fault handling method - Wiener
In order to ensure the safe and economical operation of the power system and its power generation, supply and electrical equipment, power grid users require voltage separation to operate in three ways: forward voltage regulation, reverse voltage regulation and constant voltage regulation. However, in the actual operation of the power grid, due to the change of active and reactive power output, the increase or decrease of the electrical load, the system wiring party...
|
|
The advantage of intelligent energy-saving dense busway - Wiener
Intelligent, energy-saving, dense busway, it is capable of generating outward electromagnetic wave radiation. It can be said that the line loss in the process of power transmission is greatly reduced, which can save energy and reduce electromagnetic radiation pollution. In addition, the product is also specially equipped with a radiator, which increases the heat dissipation area of the conductive bar and accelerates the ...
|
|
Tubular busbar structure layout - Wienal
1. The tubular bus is in the form of a split-phase fully insulated shielded copper tube bus.
2. The cylindrical capacitor structure is selected, and the voltage equalizing capacitor layer, the main insulation layer, and the bottom layer of the shielding street are set between the conductor and the insulating sheath, and the shielding grounding layer on the outside is connected to the grounding grid. The quantity of each layer is determined by the seller.
|
|
Introduction of busbar, busway and busway bridge - Vernal
generatrix
In the field of electricity, the busbar can also be called the busbar, busbar, etc., most of which refer to the busbar or power supply trunk in the high and low voltage cabinet, which is used to connect multiple electrical lines. The system will install various interface cards through the bus, and transmit various data to the devices connected to the interface cards.
|
|
Wiener fixed and busbar mounting
Precautions for the device
VDE 0660 Specification Section 107 / EN 60947-3 Specification / IEC 60947-3 Specification
3 poles are broken at the same time, double breakpoints.
Operator-independent, safe opening/closing, in position ...
|
|
The advantages of busway are used in cable tray installations
At the time of the cable tray installation, the wiring is not very convenient. This phenomenon can be avoided by using busway. The 5 advantages of using busway in the cable tray device are as follows:
1. Convenient connection of bus duct: the so-called plug-in bus...
|
|
There are several main ways to wire the busbar - Vernal
(1) Single bus. Single busbar, single bus segment, single bus plus bypass and single bus segment plus bypass.
(2) Tandem bus. Double busbar, double bus segment, double bus plus bypass and double bus plus bypass.
(3) Three busbars. Triple bus, triple bus section, triple bus section ...
|
|
Wiener is a common way to wiring busbars
Single bus wiring method: all outgoing wires are connected to the same busbar, which is also the most cost-effective and simplest wiring method
Single bus segmentation: The outgoing line is arranged in two parts on different sections of the single busbar, so that a power failure in the meantime does not affect the power supply of the other bus
...
|
|
Wiener Data Center Bus System
Although the service life cost of the busbar system is usually lower than that of the traditional wiring method, the busbar system still bears a considerable cost compared to other structural elements of the water supply and drainage or HVAC system.
In addition, customized busbars ...
|
|
Composition of medium and low voltage bus protection - Wiener
On the medium and low voltage side of the main transformer, the bus tie switch and the original electromagnetic relay maintenance DC circuit of each outlet, the PLC is used for logical comparison to determine whether it is a fault in the maintenance area or a fault outside the area.
...
|
|
The way in which the Wiener high-voltage busway is selected
In the selection, the following elements should be fully considered: fire protection specifications, insulation layer to flame retardant, good temperature resistance, high temperature is not easy to release harmful gases, structure type to avoid chimney effect, should give priority to the use of aggregate insulation layer bus duct, such as the use of air insulation type, it must be in the electric ...
|
|
Uses and technologies of cable junction boxes – Wienal
XBT series mine flameproof communication cable distribution box has the characteristics of small size, reasonable cable import and export, and wide coverage. Each distribution box has 4-10 inlet and outlet bells, which is suitable for HUYV type mine signal cable in coal containing sexual gas (methane) mixture (non-mining face).
|
|
Difference Between Busbar and Cable – Vernal
When the busway has not been developed and introduced, the cable is still an indispensable figure in the low-voltage distribution system, when the busway system is introduced and widely used. Whether to choose the cable or the bus duct has become a topic of endless debate. So it's hard to say which of the two is better ...
|
|
Busbar system in detail – Vernal
1. In the 60mm bus system, the square fuse type blocking switch can be directly hooked.
2. The 60mm bus system refers to the three-wire or four-wire bus spacing of 60mm.
3. Strip NH-fuse type load barrier switch with scale 00 ...
|
|
Avoidable failures in busbar systems – Wienal
Cause of bus failure
1. The internal network of bus insulators and breaker sleeves caused by surface pollution
2. The voltage transformer installed on the bus and the current transformer between the bus and the circuit breaker are faulty
3. The support of the circuit breaker or isolation switch caused by the reverse operation ...
|
|
Power system bus wiring features - Wiener
1) Single bus wiring. Single bus wiring has the advantages of simple and clear, less equipment, small investment, convenient operation and conducive to expansion, but the reliability and flexibility are poor. When there is a fault or maintenance of the bus bar or bus barrier switch, the full power supply of the bus must be disconnected.
...
|
|
Precautions for the operation of low-voltage cabinets - Wienal
1. To carry out work in all and part of the energized panels, the equipment should be overhauled and separated from the operating machinery and equipment with obvious markings.
2. The secondary winding of the voltage transformer and the transformer should have reliable grounding maintenance.
3. On the secondary circuit of the voltage transformer in operation...
|
|
Wiener DC power supply busway classification
In general, the DC power supply system is composed of a communication screen, a rectifier screen, and a DC screen. After selecting a dense bus duct, it is necessary to adjust the conventional DC power supply system: one or two large-capacity DC split-screens are installed in the communication room, and a large loop output is set in the DC split-screen; In the power room ...
|
|
Busbar system reverse operation – Wiener
1. For the charging of the spare bus, when there is a bus tie circuit breaker, the bus tie circuit breaker should be used to charge the spare bus. At this moment, the maintenance device of the bus tie circuit breaker should be fully invested, and the relevant maintenance value and time limit should be changed to a smaller one, so as to facilitate the bus tie circuit breaker when there is a problem, the bus tie circuit breaker can quickly trip, cut ...
|
|
Development of the busbar trunk system – Wiener
(1) Air-type busway
Since the mid-50s of the last century, represented by Beijing Baizhifang Airport Electrical Appliance Factory, the conductive row has been supported in the shell with insulating liner and insulated by air medium. The phase-to-phase distance is 50mm.
(2) Secret ...
|
|