Frequently Asked Questions for the Installation of Closed Busbars – Vernal

Create Date: 2024-8-30 12:03:23|Source: Woehner/Wiehner

1. The cable in and out of the bridge is not piping

2. The orientation of the bridge grounding and crossing is incorrect, and the special grounding line of the spray or painted bridge device is not equipped with a special disc gasket

3. The fireproof board of the electric well is not fixed, and the fireproof plugging is not perfect

4. The bridge is open at will, and no standard accessories are used

5. The connection between the bridge and the distribution box is not standard

6. The pipe into the bridge frame is not grounded and crossed

7. The line pipe is not in place

8. The bridge is located below the water pipe interface

9. The bridge frame and pipeline wear the fire shutter door

                              Frequently Asked Questions for the Installation of Closed Busbars – Vernal

The following points should be paid attention to in the device:

1. The metal cable tray and its bracket and the metal cable conduit introduced and drawn out must be reliably grounded.

(1) The total length of the metal cable tray and its bracket shall not be less than 2 places connected to the grounding or zero trunk line;

(2) The two ends of the connecting plate between the non-galvanized cable tray shall be made of crossover grounding wires, and the cross-section of the jumper wire shall not be less than 4mm2.

(3) The two ends of the galvanized bridge adapter do not need to cross the grounding wire, but there are no less than 2 connecting fixing bolts with locknuts or locking washers at both ends of the adapter.

2. Emergency distribution lines and normal distribution lines should be laid in separate slots; The two power circuits of dual power supply should not be laid in the same slot.

3. Strong current and weak current should be laid in slots. Different systems in weak current should be laid in slots, and weak current lines such as fire protection and induction wiring should be laid in slots.

4. Compensation methods should be adopted when the trunking, bridge and closing bus pass through the deformation joints of the building; When passing through the firewall and fireproof floor, the trunking and the surface of the bridge should adopt fireproof blocking methods.

5. Bolts should be used between the bridge and the bracket, and the nut should be located on the outside of the bridge.

6. Close the connection of the plug-in bus must comply with the provisions of the product technical documents, when laying vertically, the accessory support should be selected at the floor slab, and the floor height is more than 3.5m and the end of the bus bar should be fixed horizontally when the bracket is suspended.

More on that
The connection method of the tubular busbar The connection method of the tubular busbar

In the industry, tubular bus bar can be described as one of the more common equipment, with high mechanical strength, good insulation, wide range of application and other characteristics of many enterprises. So do you know what are the ways to link tubular busbars? ...

Advantages of a shared DC bus system – Wienal Advantages of a shared DC bus system – Wienal

The shared DC bus system is the future development direction in the application of multi-drive motors, which makes reasonable use of the regenerative energy of the system together with better dynamic and static functions and speed regulation accuracy, eliminating a lot of braking units and braking resistors, and the energy efficiency ratio of the system has been greatly improved.

Precautions for the installation of explosion-proof distribution boxes - Vernal Precautions for the installation of explosion-proof distribution boxes - Vernal

The protection level mark of explosion-proof distribution box is the protection level of IP products that we often mention, which has two parameters, one represents the level of avoiding foreign objects from entering the shell, and the second represents the level of waterproof entering the shell. Installation of explosion-proof ...

Technical requirements for busway system – Wiener busbar Technical requirements for busway system – Wiener busbar

1. The conductor of the bus bar is a high conductivity TMY electrical hard copper bar rolled by T2 electrolytic copper, and the purity of copper must be ≥ 99.95%, and copper-aluminum alloy or other mixed alloy non-pure copper conductor materials shall not be used, and the copper plate is tin plated on the full length. 2. The raw material of the neutral wire and the phase wire in the bus system is the same.

Bus voltage non-system equipment failure and solution - Wienal Bus voltage non-system equipment failure and solution - Wienal

In order to ensure the safe and economical operation of the power system and its power generation, supply and electrical equipment, power grid users require the voltage to operate in three ways: forward voltage regulation, reverse voltage regulation and constant voltage regulation. However, when the power grid is in practice, due to the change of active and reactive power output, the increase or decrease of electricity load, and the system wiring party...

Fuse selection method - Wiener busbar Fuse selection method - Wiener busbar

1. Select the model of the fuse according to the circuit requirements and device conditions. Circuits with small capacity are semi-enclosed or enclosed without fillers; The selection of large short-circuit current has a packing closed type; Semiconductor component maintenance selection of quick fuses. ...

Introduction to Laminated Busbar System – Wiener Introduction to Laminated Busbar System – Wiener

In the power system, the bus connects the various current-carrying branch circuits in the power distribution device together, and plays the role of collecting, distributing and transmitting electric energy; According to the appearance and structure, the bus bar is roughly divided into three categories: hard busbar, soft busbar and closed busbar. ...

A detailed description of the Wiener comb busbar and connection terminals A detailed description of the Wiener comb busbar and connection terminals

The Wiener comb busbars and connection terminals are available with QUADRON®CrossLinkBreaker in size 000/00 Recommended installation: Wire entry at the lower end of the NH-fuse disconnector through the comb busbar. In the mounting position ...

There are several main ways to wiring the Wiener bus There are several main ways to wiring the Wiener bus

Bus line refers to a product made of copper (copper bar) and aluminum material with high conductivity to transmit electrical energy and have the ability to collect and distribute electricity. The main conductor used by the power station or substation to transmit electrical energy. Through it, the output of the generator, transformer or rectifier ...

Ferromagnetic resonance occurs in the busbar system – Vernal Ferromagnetic resonance occurs in the busbar system – Vernal

The ferromagnetic resonance of the bus system is divided into parallel ferromagnetic resonance and series ferromagnetic resonance. Parallel ferromagnetic resonance refers to the resonance of the ground capacitance of the bus system and the nonlinear inductance of the bus electromagnetic voltage transformer (primary neutral grounding) in the neutral point ungrounded system or small current grounding system.

The operation procedure of the dual power supply automatic transfer switch The operation procedure of the dual power supply automatic transfer switch

The dual-supply ACT is a new generation of products. Beautiful appearance, good quality, long life, simple It is composed of two three-pole or four-pole shell graders and their parts/mechanical interlocking transmission arrangements, intelligent controllers, etc., which are divided into two structures: integral and split.

Differences and differences between busway and other busbars Differences and differences between busway and other busbars

The busbar and busway are actually one open and one closed, and the other is not closed. The closed busway is referred to as the busway, that is, the busway is sealed The closure of the busbar, the closure of the busbar and the busway all refer to the same east...

The advantages of low-voltage closed busbar system without punching connections The advantages of low-voltage closed busbar system without punching connections

1. Save space. The components are attached to the busbar, which can save 1/3 of the size of the box transformer. 2. Operation**. The busbars are placed behind the components, and the upper and lower plates can be sealed to prevent touch protection. 3. Improve the stability and reliability of operation, improve the dynamic and thermal stability, and the bus bar is not perforated.

Precautions for the operation of low-voltage cabinets - Wienal Precautions for the operation of low-voltage cabinets - Wienal

1. To carry out work in all and part of the energized panels, the equipment should be overhauled and separated from the operating machinery and equipment with obvious markings. 2. The secondary winding of the voltage transformer and the transformer should have reliable grounding maintenance. 3. On the secondary circuit of the voltage transformer in operation...

The innovation of Wiener 185Power in the low-voltage main distribution system The innovation of Wiener 185Power in the low-voltage main distribution system

The new base system adapter creates a new type of solution in combination with the 185Power system, which was not possible before. CrossBoard® products can be easily connected to the adapter of the base system via the CrossLink® interface. Components of DIN support rails, e.g. fuses ...

Composition of medium and low voltage bus protection - Wiener Composition of medium and low voltage bus protection - Wiener

On the medium and low voltage side of the main transformer, the bus tie switch and the original electromagnetic relay maintenance DC circuit of each outlet, the PLC is used for logical comparison to determine whether it is a fault in the maintenance area or a fault outside the area. ...

Low-voltage cabinets need temperature and humidity controllers for the reason - Vernal Low-voltage cabinets need temperature and humidity controllers for the reason - Vernal

Why is the temperature and humidity controller of the low-voltage cabinet? The application field of low-voltage cabinet is very wide, high-voltage switchgear should be one of the key electrical equipment and equipment for electromagnetic energy production scheduling and transportation, there will be some simple reasons to form high-voltage switchgear hot in specific work, low-voltage cabinet I remind you that at this time ...

Use and characteristics of AC busbar systems – Wiener Use and characteristics of AC busbar systems – Wiener

The communication and connection skills of the independent power supply system create better prospects for the power supply of the future. Hundreds of systems around the world have installed SMA's Sunny Island battery inverters to supply power to customers for a long time. The stackability of Sunny Island, i.e. multiple Sunny Islands ...

The Hazards of Arc Light – Wiener Busbar System The Hazards of Arc Light – Wiener Busbar System

The arc of the switchgear cable spacing causes the pressure and temperature in the switchgear to increase rapidly, and if not removed in time, it will cause serious harm in the following aspects: (1) The arc temperature is 2 times the appropriate solar temperature, and the large ...

Precautions for busway installation Precautions for busway installation

1. Requirements for civil engineering before installation 1. The foundation, frame, reserved holes and embedded parts meet the planning requirements of electrical equipment. 2. After the construction of the roof and floor slab, there shall be no leakage. 3. After the indoor above-ground construction is completed, mark the leveling elevation on the wall on the ground.

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top