The operation procedure of the dual power supply automatic transfer switch

Create Date: 2024-8-30 12:03:23|Source: Woehner/Wiehner

The dual-supply ACT is a new generation of products. Beautiful appearance, good quality, long life, simple It is composed of two three-pole or four-pole shell graders and their parts/mechanical interlocking transmission arrangement, intelligent controller, etc., which are divided into two structures: integral and split, and the integral type is that the controller and the operation arrangement are installed on a base; The split type is that the controller is installed on the cabinet panel, the operation arrangement is installed on the base and installed by the user in the cabinet, the controller and the operation arrangement are connected with about 2m long, and the operation steps of the dual power active transfer switch:

                              The operation procedure of the dual power supply automatic transfer switch

When there is a power outage for any reason, and the power cannot be restored within the desired time, it is necessary to enable the backup power step:

(1) Cut off the circuit breakers of the mains power supply, pull the double-throw anti-reverse switch to the side of the self-power supply, and the self-provided power supply circuit breaker in the Baote dual power supply switching box is in a disconnected state

(2) Start the standby power supply, wait for the unit to run and get off school, and then combine the power generation phase and switch, and provide each near device in the self-provided power supply

(3) Close each standby power circuit breaker in the power switching box one by one to send power to each load

(4) During the operation of the standby power supply, the operator on duty shall not leave the generator set, and adjust the voltage and plant frequency in time according to the change of load, and deal with the abnormality in time.

More on that
Wiener fixed and busbar mounting Wiener fixed and busbar mounting

Precautions for the device VDE 0660 Specification Section 107 / EN 60947-3 Specification / IEC 60947-3 Specification 3 poles are broken at the same time, double breakpoints. Operator-independent, safe opening/closing, in position ...

The busway power system is a key component - Wiener The busway power system is a key component - Wiener

The busway is one of the more critical components in the power system, and it is an important part of connecting cables to important equipment such as substations, overhead lines, transformers, circuit breakers, etc. It is widely used in various power systems, mainly for the reliable operation of power systems. ...

A detailed description of the Wiener comb busbar and connection terminals A detailed description of the Wiener comb busbar and connection terminals

The Wiener comb busbars and connection terminals are available with QUADRON®CrossLinkBreaker in size 000/00 Recommended installation: Wire entry at the lower end of the NH-fuse disconnector through the comb busbar. In the mounting position ...

Advantages of common DC bus - Wiener Advantages of common DC bus - Wiener

1. Energy saving: The energy fed back when the motor brakes can be used, so it is more energy-saving, especially for oilfield kowtow machines, cranes and other lifting equipment. 2. The power element of the equipment is high: because the motor can feed back energy, the reactive power loss is small, so the power of the equipment ...

Use and characteristics of AC busbar systems – Wiener Use and characteristics of AC busbar systems – Wiener

The communication and connection skills of the independent power supply system create better prospects for the power supply of the future. Hundreds of systems around the world have installed SMA's Sunny Island battery inverters to supply power to customers for a long time. The stackability of Sunny Island, i.e. multiple Sunny Islands ...

Frequently Asked Questions for the Installation of Closed Busbars – Vernal Frequently Asked Questions for the Installation of Closed Busbars – Vernal

1. The cable in and out of the bridge is not piping 2. The orientation of the bridge grounding and crossing is incorrect, and the special grounding line of the spray or painted bridge device is not equipped with a special disc gasket 3. The fireproof board of the electric well is not fixed, and the fireproof plugging is not perfect 4. The bridge is opened at will, and no standard accessories are used.

Technical requirements for busway system – Wiener busbar Technical requirements for busway system – Wiener busbar

1. The conductor of the bus bar is a high conductivity TMY electrical hard copper bar rolled by T2 electrolytic copper, and the purity of copper must be ≥ 99.95%, and copper-aluminum alloy or other mixed alloy non-pure copper conductor materials shall not be used, and the copper plate is tin plated on the full length. 2. The raw material of the neutral wire and the phase wire in the bus system is the same.

The innovation of Wiener 185Power in the low-voltage main distribution system The innovation of Wiener 185Power in the low-voltage main distribution system

The new base system adapter creates a new type of solution in combination with the 185Power system, which was not possible before. CrossBoard® products can be easily connected to the adapter of the base system via the CrossLink® interface. Components of DIN support rails, e.g. fuses ...

Analysis of the product characteristics of Wiener busway Analysis of the product characteristics of Wiener busway

Since the busway is made of copper bars or aluminum as conductors, it has a large current capacity and good electrical and mechanical properties. In addition, it is made of a metal trough as the shell, so it is non-flammable, safe and reliable, and has a long service life. Compared with traditional power distribution or ...

The busway phase in the low-voltage incoming line - Wiener The busway phase in the low-voltage incoming line - Wiener

According to the requirements of the relevant specifications, the placement method of the three-phase busbar can be roughly divided into two kinds according to the model of the low-voltage distribution cabinet and the different manufacturers: the horizontal placement and the placement of the down wire.

Introduction to the advantages of busway - Wiener Introduction to the advantages of busway - Wiener

The advantage of the busway is that its structural design is simple, it is composed of metal plates, which can connect the circuits together, so as to achieve the safe and reliable transmission of electric energy. In addition, its structural design can effectively assist in reducing the occurrence of short circuits, reducing heat loss, and can effectively ensure the power ...

Advantages of busbar mounted electrical equipment - Wiener Advantages of busbar mounted electrical equipment - Wiener

The novelty, flexibility and originality of the busbar device appliance. It indicates the vitality of this skill and its broad market prospects. This is the real reason why we pay attention to it. First of all, this small electrical appliance set ...

What are the modules of the Wiener bus system? What are the modules of the Wiener bus system?

The modulus of the bus system is 40mm, 60ram, 100/185mm; The bus cross-section is rectangular, double "T" (i.e., "H" shape) and three "T" (i.e., 'state') shapes; The bus system can be three-wire, four-wire or five-wire, or even seven-wire, of course, it should be determined according to the needs ...

Classification of the use of busway in different places - Vernal Classification of the use of busway in different places - Vernal

(1) General bus duct Non-flame retardant and non-fire-resistant bus duct selected for general load power distribution. In the event of a short circuit, it will be incinerated until it is connected to other busbars, which can easily cause fire accidents. (2) Flame retardant bus duct ...

The importance of room power supply and busbar system – Vernal The importance of room power supply and busbar system – Vernal

In today's information society, the computer room is a very common equipment, so the most important thing in a computer room is the bus system, which is the center and skeleton of the power distribution of the entire computer room. Then a reasonable bus system will greatly improve the efficiency of the computer room. So how do you optimize ...

The difference between air-type busway and dense busway - Vernal The difference between air-type busway and dense busway - Vernal

1. The insulating medium is different: there is a certain open space between the copper bars of the air bus duct, that is to say, the insulation between the copper bars mainly depends on air, and the insulation medium between the copper bars of the dense bus duct (many people call it a closed bus duct) is an organic insulating material. 2. Copper bar placement ...

Strip Switch vs. Disconnector Circuit Breaker Comparison – Wiener Strip Switch vs. Disconnector Circuit Breaker Comparison – Wiener

Bar switches are different from regular switches. They are critical to ensuring effectiveness. For example, when the current exceeds a certain amount of time, they cause heat to be generated, allowing the fuse to switch the fuse to further assist in breaking the circuit. Therefore, as a kind of current protection device, they can achieve ...

Busbar System Vibration and Noise – Vernal Busbar System Vibration and Noise – Vernal

The bus equipment has the characteristics of beautiful appearance, compact structure, agile installation, easy to use, economical and time-saving, safe and reliable, and is one of the important parts of the low-voltage power supply system. Many scholars have conducted a multi-faceted discussion on the low-voltage bus system, and after many years of production, the bus body ...

There are several main ways to wire the busbar - Vernal There are several main ways to wire the busbar - Vernal

(1) Single bus. Single busbar, single bus segment, single bus plus bypass and single bus segment plus bypass. (2) Tandem bus. Double busbar, double bus segment, double bus plus bypass and double bus plus bypass. (3) Three busbars. Triple bus, triple bus section, triple bus section ...

Wiener busbar system PT disconnection treatment Wiener busbar system PT disconnection treatment

The judgment of PT three-phase voltage loss (symmetrical disconnection) is fundamentally the same for each manufacturer, and it is judged according to the three-phase no voltage and the current of the line. The same is true for PT asymmetrical wire breakage. After analyzing the characteristics of PT wire breaking, the specific judgment of PT asymmetric wire breaking of different manufacturers ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top