Why is the temperature and humidity controller of the low-voltage cabinet? The application field of low-voltage cabinet is very wide, high-voltage switchgear should be one of the key electrical equipment and equipment for electromagnetic energy production scheduling and transportation, there will be some simple reasons to form high-voltage switchgear hot in specific work, low-voltage cabinet I remind you, at this time, we should maintain low-voltage cabinet in time, so as to prevent things from happening.
An important factor that jeopardizes the smooth operation of the low-voltage cabinet is the temperature and humidity in the high-voltage switchgear. When the environmental humidity of the high-voltage switchgear is large, the flame retardant function of the insulator in the high-voltage switchgear decreases, but when the flame retardant function of the insulator decreases, the insulating material made into the insulator digests and absorbs the moisture of the gas a lot, resulting in the further decline of its insulation function, and so on, it will fall into a dead loop, and finally form the insulation layer of the insulator is destroyed, and the high voltage conductor is charged and discharged according to the voltage of the insulator to the ground, the short-circuit fault, and the short-circuit trip damage the machinery and equipment, which seriously endangers the smooth operation of the power grid and the machine.
Why does the low-voltage cabinet use a temperature and humidity controller?
1. If the high and low voltage switchgear is in the south, the temperature is high in summer, coupled with the high humidity of the environment, and the internal structure of the box blocks the operation of the switch and other products to form heat, which can easily lead to safety incidents.
2. If the low-voltage cabinet adopts a temperature controller that can make all kinds of electric control boxes work under certain conditions, such as low temperature in the northern winter (usually minus 5 °C-30 °C), all kinds of household appliances are delivered and used immediately, and the damage is relatively large, the control board first works the electric heater to make the ambient temperature of the box suitable for the working environment of household appliances, so as to reduce common faults and add the service life of the product.
3. The temperature and humidity controller is used to overcome the problem of condensation. The problems that lead to safety issues such as high and low voltage cabinets, central cabinets, and terminal boxes are condensation and stains. If a long period of dense fog will cause the power to be turned off in the line, and there will be a problem with the inspection after a long time, the main reason for the inspection is the formation of condensation.
Assembling of low-voltage cabinets
1. The base of the low-voltage cabinet is made and assembled
The base of the low-voltage cabinet is generally made of channel steel, and the steel specification is determined according to the size and net weight of the low-voltage cabinet. The channel steel is leveled and straightened before cutting.
2. Low-voltage cabinet unpacking inspection
Before the construction of the low-voltage cabinet, it is necessary to unpack and check the certificate of conformity and product manual, and then check whether the low-voltage cabinet is intact, and then fill in the key content in the "unpacking record of machinery and equipment".
3. Assemble low-voltage cabinets
The low-voltage cabinet is smoothly installed on the foundation channel steel, the anchor bolts between the cabinets are tightened, and the ground leveling and levelness are welded together with the foundation channel steel, and the electrical cabinet has to use 6mm soft copper wire and grounding trunk necklace as grounding protection.
|
More on that
|
Wiener busbar system PT disconnection treatment
The judgment of PT three-phase voltage loss (symmetrical disconnection) is fundamentally the same for each manufacturer, and it is judged according to the three-phase no voltage and the current of the line. The same is true for PT asymmetrical wire breakage. After analyzing the characteristics of PT wire breaking, the specific judgment of PT asymmetric wire breaking of different manufacturers ...
|
|
The common DC bus of the inverter system - Wiener
1. Three-phase AC power supply inlet
The power input of each inverter is connected in parallel on the same AC bus, and the power supply phase of the input of each inverter is consistent. In Figure 3, the circuit breaker QF is the incoming protection device for each inverter. LR is an incoming reactor, when multiple inverters are in the same ...
|
|
The difference between busway and silicone rubber inverter cable - Vernal
The internal bus duct uses high-quality T2 electrolytic copper as the transmission conductor, which has high purity, high conductivity, low loss and small heating, which is very suitable for industrial and mining enterprises that need large current load operations.
|
|
Ship unloader distribution cabinet convergence mode - Wiener
In the hardware layout planning of the ship unloader distribution cabinet, in order to omit the wiring slot pawn, save time and effort in wiring, prevent wiring errors, and make the distribution cabinet beautiful and useful, the circuit breaker inlet end in the distribution cabinet will use the confluence method. Here are a few commonly used ways to combine the flow with Siemens circuit breakers.
|
|
Distribution cabinet bus calculation method - Vilna
1. The main bus at the upper end of the low-voltage distribution cabinet is calculated according to the material and cross-section in the extension meter. The bus bar connected to the main bus at the upper end of the switch is not accounted for and is included in the low-voltage distribution cabinet.
2. The transformer mainly depends on how large the load is, according to your switchgear can be calculated to match the transformer, but not the same...
|
|
The innovation of Wiener 185Power in the low-voltage main distribution system
The new base system adapter creates a new type of solution in combination with the 185Power system, which was not possible before. CrossBoard® products can be easily connected to the adapter of the base system via the CrossLink® interface. Components of DIN support rails, e.g. fuses ...
|
|
Wiener bus load forecasting method
Bus load guessing is a kind of power system load guessing, and the bus system load can be defined as the sum of the terminal load of a relatively small power supply area supplied by the main transformer of the substation, which is the refinement of the system load. Bus load guessing generally only carries out short-term load guessing, and the result is ...
|
|
Advantages of a shared DC bus system – Wienal
The shared DC bus system is the future development direction in the application of multi-drive motors, which makes reasonable use of the regenerative energy of the system together with better dynamic and static functions and speed regulation accuracy, eliminating a lot of braking units and braking resistors, and the energy efficiency ratio of the system has been greatly improved.
|
|
Power system bus wiring method - Vernal
(1) Single busbar. Single busbar, single bus segment, single bus plus bypass, and single bus segment plus bypass.
(2) Double busbar. Double-busbar, double-busbar segmentation, dual-busbar plus bypass, and dual-busbar segmentation plus bypass.
(3)3/2 wiring ...
|
|
Busway ultimate temperature rise value - Wiener
The ultimate temperature value-added of the busway is directly related to the current-carrying capacity of the conductor and the potential safety hazards, so it is necessary to mark the limiting temperature value-added of the busway, which is the most critical safety technical parameter of the busway.
Follow me...
|
|
The operation procedure of the dual power supply automatic transfer switch
The dual-supply ACT is a new generation of products. Beautiful appearance, good quality, long life, simple It is composed of two three-pole or four-pole shell graders and their parts/mechanical interlocking transmission arrangements, intelligent controllers, etc., which are divided into two structures: integral and split.
|
|
Several faults of the Wiener bus system can be avoided
Cause of bus failure
1. The inner network of the bus insulator and the breaker sleeve caused by the dirty appearance
2. The voltage transformer installed on the bus and the current transformer between the bus and the circuit breaker fail
3. Reverse gate ...
|
|
The service life of the lighting power busway – Wienal
The system consists of a current box, a bus body, a branch plug and device accessories.
When the heat dissipation of conductive copper strip is effectively improved, the contact between the copper strip and the inner wall of the tube is reduced, the insulation resistance and anti-aging ability of the tube body are strengthened, and then the service life of the tube body is extended. The longevity of the tube far exceeds ...
|
|
Advantages of pluggable busway
1. The plug-in bus duct has strong overload capacity
The overload capacity of the bus duct is strong, depending on the high working temperature of the insulation material it uses, and the working temperature of 105 is selected for the insulation data used in the bus duct, and the radiation cross-linked flame retardant winding tape with a working temperature of more than 140 °C has been developed.
|
|
Technical features of Wiener closed busbar
The out-of-phase shut-off bus adopts a fully connected structure, with optimized design, reasonable design, stable and reliable operation. Choose either natural cooling or forced air cooling.
The out-of-phase closing bus is to support the conductors of each phase bus with insulators and close them in their respective shells, and the shells themselves are electrically connected, ...
|
|
220V DC Hazard in Busbar System – Wiener
The grounding of the DC system should include two conditions: the one-point grounding of the DC system and the two-point grounding of the DC system.
In the DC system, the positive and negative poles of DC are insulated from the ground, and they do not cause any harm when generating a ground current because there is no path to constitute a grounding current, but the ground of one pole is long.
|
|
Comparison of several insulated tubular busbars
The use of insulated tube bus in China has a history of nearly 20 years, and it has made a historic contribution to reducing the layout space of the distribution bus and improving the reliability of the bus operation. There are many manufacturers who supply this product, and their production processes are uneven, and the differences in processes are mainly reflected in the ...
|
|
The difference between metal busbar and closed busbar - EVOC
The nature is different
Busbar: It is a common path on which multiple devices are connected in the form of side-by-side branches.
Busway: It is a closed metal equipment composed of copper and aluminum busbars.
Different uses
Mother...
|
|
What are the hazards of 220V DC in the bus system - Wiener
The grounding of the DC system should include two situations: the one-point grounding of the DC system and the two-point grounding of the DC system.
In the DC system, the positive and negative poles of DC are insulated from the ground, and there is no grounding current when generating a ground current when one pole is grounded.
|
|
The importance of busbar systems in low-voltage switchgear
One of the characteristics of low-voltage switchgear is the multi-functional busbar system.
The bus bar is a conductor that connects large electrical equipment such as generators and transformers with various electrical equipment. The role of the bus is to, sub-...
|
|