Precautions for the operation of low-voltage cabinets - Wienal

Create Date: 2024-8-30 12:03:23|Source: Woehner/Wiehner

1. To carry out work in all and part of the energized panels, the equipment should be overhauled and separated from the operating machinery and equipment with obvious markings.

2. The secondary winding of the voltage transformer and the transformer should have reliable grounding maintenance.

3. When working on the secondary circuit of the running voltage transformer, the following safety precautions should be taken:

                               Precautions for the operation of low-voltage cabinets - Wienal

4. Stop the current circuit from being cut off.

5. In order to reliably short-circuit the secondary solenoid coil of the voltage transformer, it is necessary to select short-circuit defect pieces and short distances, and prohibit the transmission line surrounding.

6. Do not do any work on the control circuit and transmission line between the voltage transformer and the short-circuit faulty terminal.

7. Insulating things should be selected, insulated things should be worn, and if it is necessary to stop using relevant relay maintenance before operation.

8. When connecting the temporary load, it must be equipped with a special power switch and circuit breaker.

9. During the secondary circuit plug-in experiment, in order to prevent the secondary side from the primary reverse transformer, in addition to breaking the secondary circuit, the next circuit breaker should also be selected.

10. Before the secondary circuit is plugged in or the AC withstand voltage test, the maintenance workers and relevant personnel should be notified, and soldiers should be sent to guard the scene, check the control circuit, and confirm that no one is working before it can be charged.

11. Check the relevant staff of power-off maintenance and secondary circuit, and stop any reverse operation without the consent of the staff.

More on that
Low-voltage cabinet for capacitance compensation – Wienal Low-voltage cabinet for capacitance compensation – Wienal

Capacitor compensation is indispensable in low-voltage cabinets, so what is the effect of capacitor compensation. The meaning of this is that it acts as a capacitor. Let's take a look at the principle of capacitor compensation first, when the capacitor is compensated, the capacitor and the load are connected in parallel, and the capacitor is like a bin. When the load increases, the power supply has internal resistance, so that ...

Low-voltage enclosed busway function - Wiener Low-voltage enclosed busway function - Wiener

Phase-off bus is a kind of high-current transmission equipment widely used in the outgoing circuit of generators of 50MW and above and the branch circuit of the factory The phase-off busbar, conductor and shell are made of aluminum plate coil and welding, with the following characteristics: ...

The operation procedure of the dual power supply automatic transfer switch The operation procedure of the dual power supply automatic transfer switch

The dual-supply ACT is a new generation of products. Beautiful appearance, good quality, long life, simple It is composed of two three-pole or four-pole shell graders and their parts/mechanical interlocking transmission arrangements, intelligent controllers, etc., which are divided into two structures: integral and split.

Characteristics of the common box closed busbar - Wiener Characteristics of the common box closed busbar - Wiener

The common box closed bus includes the non-phase isolated, common box closed bus, phase isolated common box closed bus and AC and DC excitation common box bus, which are used for current transmission between the generator lead wire below 100MW and the low-voltage side of the main transformer or between the low-voltage side of the transformer and the high-voltage distribution device of the unit of 75MW and above.

Wiener busway specification standard parameters Wiener busway specification standard parameters

1. The standard scale of the bus duct This specification regulates the terminology, skill requirements and test methods of the insulated bus trunk system (bus duct) and its plug-in feed box (hereinafter referred to as the feed box). This specification specification applies to additional voltage AC to 660V...

Busbar system in detail – Vernal Busbar system in detail – Vernal

1. In the 60mm bus system, the square fuse type blocking switch can be directly hooked. 2. The 60mm bus system refers to the three-wire or four-wire bus spacing of 60mm. 3. Strip NH-fuse type load barrier switch with scale 00 ...

Features of busway power supply system - Wiener Features of busway power supply system - Wiener

1. Trunk power distribution system, simple wiring and reliable operation. 2. It is convenient to tap, and you can tap without cutting off the main power supply. Large power supply capacity up to 6300A current-carrying capacity. 3. High dielectric strength, strong overload, superior fire performance. Good heat dissipation performance, low impedance ...

Bus voltage non-system equipment fault handling method - Wiener Bus voltage non-system equipment fault handling method - Wiener

In order to ensure the safe and economical operation of the power system and its power generation, supply and electrical equipment, power grid users require voltage separation to operate in three ways: forward voltage regulation, reverse voltage regulation and constant voltage regulation. However, in the actual operation of the power grid, due to the change of active and reactive power output, the increase or decrease of the electrical load, the system wiring party...

The importance of busbar systems in low-voltage switchgear The importance of busbar systems in low-voltage switchgear

One of the characteristics of low-voltage switchgear is the multi-functional busbar system. The bus bar is a conductor that connects large electrical equipment such as generators and transformers with various electrical equipment. The role of the bus is to, sub-...

Busway installation method - Wiener Busway installation method - Wiener

1. Busway horizontal device, the interval between the two brackets is ≯2500mm, and the interval between straight devices is ≯3600mm; 2. When the device bracket is straight, it should be drilled with the channel side plate and fastened with M6-M8 bolts. 3. In the process of installation construction, priority should be given to the power supply system, ...

Laminated busbar system – Wiener Laminated busbar system – Wiener

In the power system, the bus connects the various current-carrying branch circuits in the power distribution device together, and plays the role of collecting, distributing and transmitting electric energy; According to the appearance and structure, the bus bar is roughly divided into three categories: hard busbar, soft busbar and closed busbar. ...

What are the characteristics of the bus wiring method of the power system? What are the characteristics of the bus wiring method of the power system?

(1) Single bus wiring. Single bus wiring has the advantages of simplicity and clarity, less equipment, less investment, and convenient operation and expansion, but its reliability and activity are poor. When the bus or bus separator is faulty or overhauled, all power to the bus must be disconnected. ...

The difference between air-type busway and dense busway - Vernal The difference between air-type busway and dense busway - Vernal

1. The insulating medium is different: there is a certain open space between the copper bars of the air bus duct, that is to say, the insulation between the copper bars mainly depends on air, and the insulation medium between the copper bars of the dense bus duct (many people call it a closed bus duct) is an organic insulating material. 2. Copper bar placement ...

Advantages of common DC bus - Wiener Advantages of common DC bus - Wiener

1. Energy saving: The energy fed back when the motor brakes can be used, so it is more energy-saving, especially for oilfield kowtow machines, cranes and other lifting equipment. 2. The power element of the equipment is high: because the motor can feed back energy, the reactive power loss is small, so the power of the equipment ...

Bus voltage non-system equipment failure and solution Bus voltage non-system equipment failure and solution

In order to ensure the safe and economical operation of the power system and its power generation, supply and electrical equipment, power grid users require the voltage to operate in three ways: forward voltage regulation, reverse voltage regulation and constant voltage regulation. However, when the power grid is in practice, due to the change of active and reactive power output, the increase or decrease of electricity load, and the system wiring party...

Uses and technologies of cable junction boxes – Wienal Uses and technologies of cable junction boxes – Wienal

XBT series mine flameproof communication cable distribution box has the characteristics of small size, reasonable cable import and export, and wide coverage. Each distribution box has 4-10 inlet and outlet bells, which is suitable for HUYV type mine signal cable in coal containing sexual gas (methane) mixture (non-mining face).

Introduction to several power supply systems – Wienal Introduction to several power supply systems – Wienal

At present, China has five power supply systems: IT, TT, TN-c, TN-c-s and TN-S. They have their own advantages and disadvantages, and we should choose sensitively according to the actual situation in life. Five power supply systems 1.IT power supply system In a ...

Wiener busway plug-in box wiring method Wiener busway plug-in box wiring method

The bus duct bracket has to be firmly installed, and the bus duct should be correctly placed according to the segment sequence number, phase sequence, number, direction and device mark, and when the sections are connected, the adjacent section of the bus duct should be aligned, and the conductor and shell of the bus duct should not accept mechanical stress after the connection. ...

Conductor and bus welding requirements - Wiener Conductor and bus welding requirements - Wiener

1. Before welding, it is necessary to check whether the welding equipment is defective, whether the grounding of the electrical equipment is reliable, and strictly abide by the "welder safety operation procedures" when welding. 2. Correct wires and busbars, and prohibit the use of handleless files. ...

Mesh tray reduces the cost of replacing cables – Wiener Mesh tray reduces the cost of replacing cables – Wiener

(1) Simple maintenance and repair operations Equipment is often added or removed or changed in the computer room, and cables are removed or added at the same time, and the grid bridge with open structure can observe the cables to the maximum extent, so it is easy to distinguish the cables that need to be replaced, so that maintenance and repair ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top