The innovation of Wiener 185Power in the low-voltage main distribution system

Create Date: 2024-8-30 12:03:23|Source: Woehner/Wiehner

The new base system adapter creates a new type of solution in combination with the 185Power system, which was not possible before. CrossBoard® products can be easily connected to the adapter of the base system via the CrossLink® interface. Components of the DIN support rails, such as fuse holders (e.g. control cabinet lighting) can also be mounted on the base system adapter.
                                  The innovation of Wiener 185Power in the low-voltage main distribution system
EQUES®185Power – Base adapter for CrossBoard® busbar systems

In order to be able to use the CrossBoard® series in the 185Power system

Wiener offers a new platform for more product installations.

The following products can be connected "directly" to the 185Power system using the platform:

Circuit breakers up to 160A are installed via EQUES®

Motor protection switch or motor start combination switch

BROOME10®, OMUS®, MOTUS® electrical components

Busbar type NH fuse type disconnector

Connect the module

Benefits at a glance:

Installation and wiring are simple and easy

Multiple connection possibilities

The packaging density is compact

Up to 3 current transformers can be installed at the same time

QUADRON®185Power- 4-in-1NH Fuse Disconnector

In this platform, four NH fuse disconnectors can be connected "directly" to the 185POWER system.

Benefits at a glance:

4 NH fuse-type disconnectors are pre-connected

Easy to install and wiring

The packaging density is compact

The wiring tensioners can be used for Cu and Al wires up to 50 mm²

Up to 3 current transformers can be installed at the same time

More on that
Introduction to Laminated Busbar System – Wiener Introduction to Laminated Busbar System – Wiener

In the power system, the bus connects the various current-carrying branch circuits in the power distribution device together, and plays the role of collecting, distributing and transmitting electric energy; According to the appearance and structure, the bus bar is roughly divided into three categories: hard busbar, soft busbar and closed busbar. ...

How is the Wiener bus system generally debugged in sections? How is the Wiener bus system generally debugged in sections?

Bus refers to the connection of voltage distribution devices at all levels in the substation, as well as the connection of electrical equipment such as transformers and corresponding distribution devices, most of which use bare wires or stranded wires with rectangular or circular sections. The role of the bus bar is to collect, distribute and transmit electrical energy. According to the structure, the bus bar is divided into hard busbar, soft ...

Analysis of the conditions for the use of sealed busbars - Wienal Analysis of the conditions for the use of sealed busbars - Wienal

Ambient air temperature: turn off the busbar system to benchmark the ambient air temperature; Unless otherwise ruled, the manufacturer should give an additional current to shut down the busbar system at a base ambient air temperature of 35°C; If applicable, the manufacturer should give an additional coefficient k: (K1=1 at 35°C) in order to determine the size of the package.

The service life of the lighting power busway – Wienal The service life of the lighting power busway – Wienal

The system consists of a current box, a bus body, a branch plug and device accessories. When the heat dissipation of conductive copper strip is effectively improved, the contact between the copper strip and the inner wall of the tube is reduced, the insulation resistance and anti-aging ability of the tube body are strengthened, and then the service life of the tube body is extended. The longevity of the tube far exceeds ...

Scenarios for the use of various types of busbars - Vernal Scenarios for the use of various types of busbars - Vernal

1. The bus bar is divided into hard bus bar and soft bus bar. 2. According to different shapes, hard busbars can be divided into: rectangular busbars, tubular busbars, trough busbars, diamond busbars, etc. 3. Rectangular busbar is a commonly used busbar. According to its material ...

Busbar system in detail – Vernal Busbar system in detail – Vernal

1. In the 60mm bus system, the square fuse type blocking switch can be directly hooked. 2. The 60mm bus system refers to the three-wire or four-wire bus spacing of 60mm. 3. Strip NH-fuse type load barrier switch with scale 00 ...

220V DC Hazard of Bus System – Wiener 220V DC Hazard of Bus System – Wiener

The grounding of the DC system should include two situations: the one-point grounding of the DC system and the two-point grounding of the DC system. In the DC system, the positive and negative poles of the DC are insulated from the ground, and when the ground of one pole is generated, there is no grounding current due to the fact that there is no grounding current.

Application of busway – Wiener Application of busway – Wiener

The busway system is an efficient power distribution device, especially suitable for the needs of high-rise buildings and large-scale factories for reasonable wiring. With the presentation of modern engineering equipment and equipment, the electricity consumption of all walks of life has increased rapidly, especially many high-rise buildings and large factories. Traditional cables serve as ...

Frequently Asked Questions for the Installation of Closed Busbars – Vernal Frequently Asked Questions for the Installation of Closed Busbars – Vernal

1. The cable in and out of the bridge is not piping 2. The orientation of the bridge grounding and crossing is incorrect, and the special grounding line of the spray or painted bridge device is not equipped with a special disc gasket 3. The fireproof board of the electric well is not fixed, and the fireproof plugging is not perfect 4. The bridge is opened at will, and no standard accessories are used.

Introduction to busbars, busway, and busbridges - Wiener Introduction to busbars, busway, and busbridges - Wiener

generatrix In the field of electricity, the busbar can also be called the busbar, busbar, etc., which mostly refers to the busbar or power supply trunk in the high and low voltage cabinet, which is used to connect multiple electrical lines. The system will install various interface cards through the bus, and transmit various data to the devices connected to the interface cards.

How to optimize the busbar system of the computer room - Wiener How to optimize the busbar system of the computer room - Wiener

In today's information society, the computer room is a very common equipment, so the most important thing in a computer room is the bus system, which is the center and skeleton of the power distribution of the entire computer room. Then a reasonable bus system will greatly improve the efficiency of the equipment room. So how do you optimize ...

Low-voltage dense busway uses and applications Low-voltage dense busway uses and applications

Densely insulated bus duct (hereinafter referred to as bus duct) can be communication three-phase three-wire, three-phase four-wire, three-phase five-wire system, frequency 50-60Hz, voltage to 400V, rated operating current of 250-5000A, mainly as a new type of power supply and distribution equipment in industrial and mining, enterprises and high-rise buildings. Mother with insertion day ...

Busway Installation Specification – Wiener Busway Installation Specification – Wiener

1: The basic requirements for the bus duct: 1) Conductor data: high-purity electrical copper drawn from national standard T2 electrolytic copper, with a purity of more than 99.9% and a full-length tinned copper conductor. 2) Shell: Select high-quality aluminum-magnesium alloy profiles that meet the strength, with heat dissipation ribs, and the appearance should be oxygen-proof.

Performance characteristics of low-voltage busbar system - Wienal Performance characteristics of low-voltage busbar system - Wienal

Introduction to the performance of low-voltage bus system: 1. The bus bar is not perforated, and is connected with the cable and copper bar through the connection clip or terminal 2. Switches, contactors and other electrical components can be directly hung on the bus through adapters 3. Save ...

Use and characteristics of AC busbar systems – Wiener Use and characteristics of AC busbar systems – Wiener

The communication and connection skills of the independent power supply system create better prospects for the power supply of the future. Hundreds of systems around the world have installed SMA's Sunny Island battery inverters to supply power to customers for a long time. The stackability of Sunny Island, i.e. multiple Sunny Islands ...

Advantages and disadvantages of bus full differential protection Advantages and disadvantages of bus full differential protection

Thorough differential maintenance of the bus is to connect the current transformer of all the connecting elements on the bus to the differential circuit according to the same name phase and polarity, the characteristics and transformation ratio of the current transformer should be the same, if the transformation ratio can not be together, the compensation converter can be used to compensate, satisfactory ΣI=0. ...

How to choose the right busway products - Wiener How to choose the right busway products - Wiener

1. Selection of qualified products of regular enterprises: The busway must be a product with the 3C necessary certification mark and style test report. China's busway factories are uneven, and most of the production methods are handicraft, mainly in well-off areas. When purchasing, it is necessary to thoroughly investigate the production of the factory ...

Advantages of pluggable busway Advantages of pluggable busway

1. The plug-in bus duct has strong overload capacity The overload capacity of the bus duct is strong, depending on the high working temperature of the insulation material it uses, and the working temperature of 105 is selected for the insulation data used in the bus duct, and the radiation cross-linked flame retardant winding tape with a working temperature of more than 140 °C has been developed.

What is tubular busbar and dense busbar - Wiener What is tubular busbar and dense busbar - Wiener

What is a tubular busbar Tubular bus bar is a kind of bus bar product with copper tube or aluminum alloy tube as conductor and external insulation. The tubular bus has the characteristics of high current (12000A), high mechanical strength, good insulation, wide application range, etc., ...

The role of plug-in busway – Wiener The role of plug-in busway – Wiener

Generally speaking, plug-in busway is mainly used for power transmission. We know that all conductors will have losses, and the losses caused by the flow of electricity through conductors are larger and some are smaller. For example, compared with the aluminum wire with the same wire diameter and the copper wire, the loss of aluminum is larger, and the loss of copper is smaller. That is, the conductivity ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top