Megmeet PLC - What is the difference between PLC and MCU?

Create Date: 2024-8-30 12:03:23|Source: MEGMEET

1. PLC is a relatively mature control system composed of single-chip microcomputer, which is the product of a mature and stable single-chip microcomputer application system that has been debugged. It is highly versatile.

2. The single-chip microcomputer can form a variety of application systems, and the application range is wider. As far as a single "microcontroller" is concerned, it is just an integrated circuit, which must be formed into a system with other components and software before it can be used.

3. From the point of view of engineering application, it is fast and convenient to use PLC for a single project or a project with few repetitions, with high success rate and good reliability, but high cost.

4. For a large number of supporting projects, the single-chip microcomputer system has the advantages of low cost and high efficiency, but to make the system stable requires considerable R&D strength and industry experience.
Megmeet PLC - What is the difference between PLC and MCU?

More on that
Megmeet servo drive - common faults and treatment methods of servo drives Megmeet servo drive - common faults and treatment methods of servo drives

1. The motor runs differently in both directions Cause of failure: The phase of the brushless motor is wrong; The deviation potentiometer is in the wrong position. Solution: Detect or detect the correct phase; Reposition the potentiometer. 2. The motor speed is abnormal Cause of failure ...

Megmeet welding machine - an introduction to the advantages and disadvantages of resistance welding Megmeet welding machine - an introduction to the advantages and disadvantages of resistance welding

Advantages of resistance welding: 1。 When a nugget is formed, it is always surrounded by a ring of plastic, the molten metal is isolated from the air, and the metallurgical process is simple 2。 The heating time is short, the heat is concentrated, the heat affected zone is small, and the deformation and stress are small. In general, there is no need to arrange calibration and heat after welding.

Common faults of Megmeet drives and how to deal with them Common faults of Megmeet drives and how to deal with them

1. When the oscilloscope looks at the current monitoring output of the driver, it finds that it is all noisy and cannot be read Cause: The current monitoring output is not blocked from the AC power supply (transformer). Solution: You can use a DC voltmeter to detect and investigate. 2. Servo motor high speed ...

The cause and treatment method of the fault code Eroc1 of Megmeet inverter The cause and treatment method of the fault code Eroc1 of Megmeet inverter

1. Overcurrent fault of inverter Fault Code: OCF. (1) Fault name: inverter overcurrent fault (2) The cause of the failure: the motor nameplate data input is incorrect: the load dragged by the motor is too heavy: the machinery is stuck; Motor stalled. (3) ...

Megmeet drives – the replacement steps for high-voltage drive power units Megmeet drives – the replacement steps for high-voltage drive power units

1) Shut down, so that the inverter out of the operating state; 2) Cut off the high-voltage power supply and push out the high-voltage cabinet trolley (when there is a bypass cabinet. The inverter can be isolated by the disconnecting switch of the bypass cabinet), the local or remote high-voltage disconnect switch can be locked, and the high-voltage cabinet grounding switch can be grounded; 3) Hit ...

Introduction to Megmeet welding machine Introduction to Megmeet welding machine

The EhaveCM350AR is a fully digital inverter melting multi-functional industrial heavy-duty Megmeet welding machine launched by Megmeet for global metalworking manufacturing. It brings customers higher quality and higher efficiency welding experience and value with excellent arc characteristics, reliability and high efficiency, and helps customers ...

Megmeet welding machine - failure and maintenance method of DC welding machine Megmeet welding machine - failure and maintenance method of DC welding machine

1. Fault phenomenon: light voltage abnormal indicator Cause: Due to the slow start-up action, the switch contact is not synchronized. Solution: You can turn the device off and on again. 2. Fault phenomenon: the fan does not rotate, and the abnormal voltage indicator light is lit together Causes ...

The principle and characteristics of Megmeet tungsten argon arc welding and resistance welding The principle and characteristics of Megmeet tungsten argon arc welding and resistance welding

3) Tungsten argon arc welding (TIG) Non-melting electrode gas arc welding, TIG welding, English is Tungsten Inert Gas (abbreviated TIG), also known as Gas Tungsten Arc Welding (abbreviated GTAW) The principle is: TIG welding is in argon and other inert gases.

Solutions to common faults of Megmeet inverter (2) Solutions to common faults of Megmeet inverter (2)

Fault three Fault phenomenon: There is a rebound phenomenon when the rotation starts Solution: 1. Set the start frequency P08.02 and start frequency time P08.03 appropriately (such as P08.02=P08.03=0.5) 2. Appropriately reduce the stator resistance (P03.07) and no-load current value (P03.11 ...

Megmeet inverter - the basic method and steps of inverter commissioning Megmeet inverter - the basic method and steps of inverter commissioning

1. No-load energizing test of inverter 1. Ground the grounding terminal of the inverter. 2. Connect the power input terminal of the inverter to the power supply through the leakage maintenance switch. 3. Check whether the factory display of the inverter window is normal, if it is incorrect, it should be reset, otherwise it should be ...

Megmeet inverter - the role and application of the inverter control cabinet introduction Megmeet inverter - the role and application of the inverter control cabinet introduction

Inverter control cabinet (inverter electrical control cabinet / electric control cabinet / electric control box) is an electrical control cabinet developed by using inverters from Siemens, ABB, Schneider, Fujifilm, Mitsubishi, Panasonic, Delta, Shilin, Inovance and other manufacturers. According to the needs of working conditions, AC transmission can be installed in the frequency conversion cabinet.

Megmeet inverters – what do you need to pay attention to when choosing the power of the inverter? Megmeet inverters – what do you need to pay attention to when choosing the power of the inverter?

The system efficiency is equal to the product of the efficiency of the inverter and the efficiency of the motor, and the system efficiency is higher only when both are working at higher efficiency. From the perspective of efficiency, the following points should be paid attention to when selecting the power of the inverter: 1) Inverter power value and motor power ...

Common faults and solutions of Megmeet inverter Common faults and solutions of Megmeet inverter

Fault one Fault phenomenon: the leakage protection switch trips, the inverter is energized or the equipment leakage protection switch is operated during operation Solution: 1. When the inverter drives the motor, the leakage value is larger than that of the non-inverter system, and the leakage protection value of the leakage protection switch is required to be more than 150mA, ...

Megmeet Inverter - Summary of Common Faults of High Voltage Inverter (21-32) Megmeet Inverter - Summary of Common Faults of High Voltage Inverter (21-32)

21。 The unit is overheating The radiator in the unit is equipped with a temperature switch (normally closed point), and when the temperature exceeds 85°C, the normally closed point of the temperature relay is disconnected, and the unit is overheated and faulty. Check whether the cabinet top fan is working properly, whether the unit cabinet fan switch is tripped, and whether the filter screen is blocked.

Megmeet welding machine - analysis of common problems of welding machine welding Megmeet welding machine - analysis of common problems of welding machine welding

One. It is difficult to start the arc and easy to break the arc 1. Confirm that the quality of the electrode you use is good, and the poor quality electrode may not meet the requirements of high-quality welding: 2. The welding rod that has not undergone drying treatment is also not easy to arc, and causes the arc to be unstable, so that the welding defects increase, and the welding ...

Megmeet Inverter - Precautions for the Use of Inverter (11-21) Megmeet Inverter - Precautions for the Use of Inverter (11-21)

11. For the occasion when the inverter drives the ordinary motor for constant torque operation, long-term low-speed operation should be avoided as much as possible, otherwise the heat dissipation effect of the motor will become worse and the heating will be serious. If long-term operation at low speed constant torque is required, a variable frequency motor must be selected. 12. For the promotion of negative ...

Megmeet PLC - the installation method and functional requirements of the PLC Megmeet PLC - the installation method and functional requirements of the PLC

Installation: The installation mode of PLC system is divided into centralized, remote I/O and distributed with multiple PLC networking. Centralized does not need to set up the drive remote I/O hardware, the system response is fast, and the cost is low; Remote I/O is suitable for large systems with a range of ...

Megmeet drives – what are the basic requirements for regular replacement of drive components? Megmeet drives – what are the basic requirements for regular replacement of drive components?

1. It is necessary to figure out the basic parameters and shape of the device that needs to be replaced. The basic parameters include the rated operating current, the capacitance of the capacitor, the resistance value of the resistor, the value of the GTR Darlington device (current amplification factor), the switching characteristics of the IGBT (including IPM) device, and the saturation voltage ...

Megmeet PLC - What places should be avoided when installing PLC control? Megmeet PLC - What places should be avoided when installing PLC control?

(1) The ambient temperature exceeds the range of 0-50 °C; (2) The relative humidity exceeds 85% or there is dew condensation (caused by sudden temperature changes or other factors); (3) direct sunlight; (4) There are corrosive and flammable gases, such as hydrogen chloride, ...

The application of Megmitte industrial control products in high-speed precision CNC machine tools The application of Megmitte industrial control products in high-speed precision CNC machine tools

With the rapid development of the machinery manufacturing industry, the traditional general machine tool can no longer meet the changing parts processing needs of the shopping mall. CNC machine tools have undeniably become the mainstream processing equipment of today's machinery manufacturing. In response to the special application needs of the machine tool industry, Megmeet has launched the MV series of high-function ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top