Inverter control cabinet (inverter electrical control cabinet / electric control cabinet / electric control box) is an electrical control cabinet developed by using inverters from Siemens, ABB, Schneider, Fujifilm, Mitsubishi, Panasonic, Delta, Shilin, Inovance and other manufacturers.
According to the needs of the inverter cabinet, AC input reactor, output reactor, DC reactor and EMI filter, braking unit, braking resistor, contactor, intermediate relay, thermal relay, programmable controller (PLC), programmable operation terminal (GOT), watt-hour meter, cooling fan, etc., according to the system working conditions in the inverter cabinet panel set a variety of control buttons and indicators such as forward rotation, reverse, motor speed increase, motor deceleration, jog forward, jog reversal, manual/automatic, emergency stop, frequency conversion / Power frequency, PLC control, touch screen, etc., the more stereotyped are: constant pressure water supply frequency conversion control cabinet (1 control 1, 1 control 2, 1 control 3, etc.), escalator frequency conversion control cabinet, central air conditioning circulating water pump frequency conversion cabinet, fan frequency conversion energy-saving cabinet, air compressor constant pressure air supply system (frequency converter energy-saving soft start control system), etc.
The role of the inverter control cabinet
The inverter cabinet adopts a closed cabinet structure, the protection level is generally IP20, IP21, IP30, etc., the profile skeleton is adopted, the surface is coated with plastic, and it is easy to install in the cabinet, the upper end can be configured with a busbar, and the inverter panel can be directly operated by leading to the outside of the cabinet, and can be set up for local and remote control or PC/PLC communication control as needed, with a very intuitive variety of display functions. The inverter is a special supporting product of the inverter cabinet, and its inverter speed regulation function and main technical parameters depend on the specifications and models of the internal inverter and the configuration of the periphery. The inverter cabinet is also very different according to the different uses and functions, and is generally customized according to the requirements of industry and mining. The more stereotyped ones are: constant pressure water supply frequency conversion cabinet (1 control 1, 1 control 2, 1 control 3, etc.), escalator frequency conversion control cabinet, central air conditioning circulating water pump frequency conversion cabinet, fan frequency conversion energy-saving cabinet, etc.
The application place of the inverter control cabinet
Inverter control cabinet (inverter electric control cabinet/electrical control cabinet) can be widely used in metallurgy, chemical industry, petroleum, water supply, mining, building materials, motor industry and other pumps, fans, air compressors, rolling mills, injection molding machines, belt conveyors and other medium-voltage motor equipment.
|
More on that
|
Megmeet inverter – three ways to connect the PLC to the inverter
(1) Use the analog output module of PLC to control the analog output module of the inverter The analog output module of the PLC outputs 0-5V voltage signal or 4-20mA current signal, which is used as the analog input signal of the inverter to control the output frequency of the inverter. This control method is simple to wiring, but it needs to be selected and changed.
|
|
Megmeet inverter - the daily maintenance and overhaul of the inverter
1. Regularly dust the inverter, focusing on the rectifier cabinet, inverter cabinet and control cabinet, if necessary, the rectifier module, inverter module and the circuit board in the control cabinet can be removed for dust removal. Whether the lower air inlet and upper air outlet of the inverter are dusty or blocked due to excessive dust. The inverter is due to the ...
|
|
Megmeet inverter - the basic method and steps of inverter commissioning
1. No-load energizing test of inverter
1. Ground the grounding terminal of the inverter.
2. Connect the power input terminal of the inverter to the power supply through the leakage maintenance switch.
3. Check whether the factory display of the inverter window is normal, if it is incorrect, it should be reset, otherwise it should be ...
|
|
Maintenance inspection of Megmeet inverters
1. The Megmeet rectifier module is damaged
It is usually caused by grid voltage or internal short circuit. In the case of sweeping the internal short circuit, the rectifier bridge is replaced. When dealing with faults on site, we should focus on checking the status of the user's power grid.
Such as the power grid voltage, whether there is an electric welding machine, etc.
|
|
Megmeet inverters – Routine maintenance of high-voltage inverters requires precautions
1. The operating ambient temperature of the inverter (mainly refers to the air temperature of the air inlet of the power unit cabinet) requires a minimum ambient temperature of -5 °C and a maximum ambient temperature of 40 °C. In order to improve the reliability and extend the service life of the drive, check the following items:
Air conditioning and refrigeration ...
|
|
The application of Megmitte industrial control products in high-speed precision CNC machine tools
With the rapid development of the machinery manufacturing industry, the traditional general machine tool can no longer meet the changing parts processing needs of the shopping mall. CNC machine tools have undeniably become the mainstream processing equipment of today's machinery manufacturing. In response to the special application needs of the machine tool industry, Megmeet has launched the MV series of high-function ...
|
|
Megmeet drives – safety precautions for the installation of drives
When the inverter is installed and wired;
Note: When more than two inverters are installed in the same cabinet, please pay attention to the installation position and spacing to ensure the heat dissipation effect.
Dangerous:
1. It should be operated by professional electrical engineering personnel, otherwise there is a risk of electric shock.
2. Please make sure before wiring...
|
|
Megmeet PLC – the three programming languages of PLC
1. The ladder diagram language is the most commonly used programming language in PLC programming. The CPU reads physical input into a memory table, often referred to as an "input table". The form is evaluated for use in the procedure. Different platforms, using different types of registers; In each scan cycle, follow from left to right, ...
|
|
Hollysys edge intelligent controller and edge intelligent all-in-one machine launched new products
Transportation power, urban rail responsibility. With the vigorous development of emerging technologies such as 5G, cloud computing, big data, and artificial intelligence, more innovative technologies are accelerating the empowerment of urban rail transit, and smart urban rail is ushering in a "golden age" of development. As a deep cultivator in the field of smart urban rail, Hollysys adheres to technological innovation.
|
|
Common faults of Megmeet drives and how to deal with them
1. When the oscilloscope looks at the current monitoring output of the driver, it finds that it is all noisy and cannot be read
Cause: The current monitoring output is not blocked from the AC power supply (transformer).
Solution: You can use a DC voltmeter to detect and investigate.
2. Servo motor high speed ...
|
|
Megmeet welding machine - the application and precautions for the use of butt welding machine
The butt welding machine should be settled indoors, and should have a reliable grounding or zero connection, when a plurality of butt welding machines are connected to each other, the distance from each other shall not be less than 3m, and they should be connected to different corresponding power grids, and should have their own knife switches.
Before welding, the pressure of the butt welder should be checked and determined.
|
|
Megmeet PLC - What are the main components of PLC control cabinet?
1. Air switch
Air switch is also called air circuit breaker, referred to as air open, is an indispensable component of the control cabinet, usually from the outside into the cabinet of power supply, must go through the air open, in order to reach the inside, the function of air open in addition to the power supply, more as short circuit protection and overload protection...
|
|
Megmeet PLC – the maintenance steps of the PLC control cabinet
1. Data backup
When carrying out maintenance, we must cut off the power, data backup between power outages is an important link, for the data that needs to be archived for a long time, you can back up the historical trend data to the mobile hard disk, and then turn off the Windows-based operating system (Note...
|
|
Common faults and solutions of Megmeet PLC
1. Do not execute the program: The input check is identified by the input LED indicator or the input monitor composed of a writer. When the input LED is not lit, it can be preliminarily determined that the external input system is faulty, and then check with the multimeter.
If the output voltage is not normal, it can be determined that ...
|
|
Megmeet inverter - a common measure for anti-interference of high-voltage inverters
(1) The E end of the high-voltage inverter should be connected to the shell of the control cabinet and the motor, and should be connected to the ground, and the grounding resistance should be less than 100Ω, which can absorb surge interference.
(2) The input or output of the high-voltage inverter is equipped with an inductive magnetic ring filter. Flat and 3-4 turns, helps to inhibit ...
|
|
Failure and maintenance of welding machines
1. Damage to the welding power supply. Due to the high current and high voltage during welding, when the welding current exceeds 20% of the rated value, overcurrent protection will appear, so that the circuit will automatically cut off the power supply. In addition, if the welding time is too long, it can also cause overcurrent. Therefore, we should try our best to ...
|
|
Megmeet MC100 series plc – the right hand man in refrigeration equipment
First, the process requirements
When the low-pressure pressure collected by the system is greater than the upper low-pressure pressure set by the touch screen, the compression time will be loaded according to the set loading time, and the lower pressure will be reduced according to the set load reduction time.
The high pressure collected is greater than that on the high pressure ...
|
|
Megmeet drives – what are the basic requirements for regular replacement of drive components?
1. It is necessary to figure out the basic parameters and shape of the device that needs to be replaced. The basic parameters include the rated operating current, the capacitance of the capacitor, the resistance value of the resistor, the value of the GTR Darlington device (current amplification factor), the switching characteristics of the IGBT (including IPM) device, and the saturation voltage ...
|
|
Megmeet inverter - common faults and treatment methods of high-voltage inverters
1. Control through this abnormal failure
The abnormal fault of the control channel is usually caused by the optical fiber communication between the sub-PWM board and the power unit board, which is generally caused by the following situations:
1. Poor contact of the optical fiber connection part or falling off of the optical fiber head;
2. Optical fiber signal transmitter/receiver ...
|
|
Megmeet PLC - Introduction to the basic structure of PLC controller
1. Power supply
The power supply of the PLC plays a very important role in the whole system. It can't work properly without a good and reliable power supply system, so PLC manufacturers also attach great importance to the design and manufacture of power supplies. General AC voltage fluctuations are +10% (+15%) ...
|
|