Create Date: 2024-8-30 12:03:23|Source: MEGMEET

(1) The ambient temperature exceeds the range of 0-50 °C;

(2) The relative humidity exceeds 85% or there is dew condensation (caused by sudden temperature changes or other factors);

(3) direct sunlight;

(4) Corrosive and flammable gases, such as hydrogen chloride, hydrogen sulfide, etc.;

(5) Measure iron filings and dust;

(6) Frequent or continuous vibration, the vibration frequency is 10-55Hz, and the amplitude is 0.5mm (peak-peak);

(7) Shocks exceeding 10g (acceleration due to gravity).
Megmeet PLC - What places should be avoided when installing PLC control?

More on that
Megmeet Inverter - Precautions for the Use of Inverter (1-10) Megmeet Inverter - Precautions for the Use of Inverter (1-10)

1. The inverter must be selected correctly. 2. Read the product manual carefully, and wiring, installation and use in accordance with the requirements of the manual. 3. The inverter device should be reliably grounded, and the radio frequency interference should be suppressed to prevent the inverter from causing electric shock due to leakage. 4、 ...

Megmeet drives – a common fault in low-voltage drives Megmeet drives – a common fault in low-voltage drives

External electromagnetic interference can easily cause malfunctions If there are interference sources around the inverter, they will invade the inside of the inverter through radiation or power lines, causing the control loop to malfunction, causing abnormal operation or shutdown, and even damage to the inverter in severe cases. Noise suppression on the outside ...

Megmeet PLC – the application of PLC Megmeet PLC – the application of PLC

Open-loop control Open-loop control of switching quantity is the most basic control function of PLC. The instruction system of PLC has powerful logic operation ability, and it is easy to realize various logic control methods such as timing, counting, and sequential (stepping). Most PLCs are used to replace traditional relay contactors...

Maintenance method of Megmeet PLC Maintenance method of Megmeet PLC

1. The electrical control cabinet installed with PLC should have a clean and dry environment. Moisture-absorbing dry materials should be placed inside, and the splashing of coolant and oil mist should be prevented. 2. Regardless of the system working or shutdown, the electrical cabinet door should always be closed, and the electrical components should be kept in a good state.

Megmeet PLC – the maintenance steps of the PLC control cabinet Megmeet PLC – the maintenance steps of the PLC control cabinet

1. Data backup When carrying out maintenance, we must cut off the power, data backup between power outages is an important link, for the data that needs to be archived for a long time, you can back up the historical trend data to the mobile hard disk, and then turn off the Windows-based operating system (Note...

Megmeet PLC - What is the difference between PLC and servo control system Megmeet PLC - What is the difference between PLC and servo control system

1. The meaning of the representation is different: PLC is the abbreviation of planar optical waveguide (technology), the so-called planar optical waveguide, means that the optical waveguide is located in a plane. A servo control system is a feedback control system used to accurately follow or reproduce a certain process.

Megmeet inverter mv600 alarm code ENOC2 Megmeet inverter mv600 alarm code ENOC2

1. If there is a sharp acceleration or deceleration, please extend the acceleration and deceleration time. 2. Avoid rapid increase in load. 3. Check whether there is a short circuit in the UVW of the motor terminal. 4. The module is damaged, and the drive circuit is damaged, resulting in an overcurrent alarm. ...

Megmeet inverter - inverter braking mode and advantages and disadvantages introduction Megmeet inverter - inverter braking mode and advantages and disadvantages introduction

What are the braking methods of the inverter? Generally speaking, braking refers to the technical measures taken during the operation of the motor due to fault protection or man-made active shutdown, and the commonly used inverter braking methods include energy consumption braking, feedback braking, DC braking and DC feedback braking. ...

Megmeet PLC - What are the five stages of the PLC work process? Megmeet PLC - What are the five stages of the PLC work process?

1. Common processing: reset the monitoring timer, perform hardware checks, user memory checks, etc. 2. Program execution: The CPU interprets and executes each instruction in the order of first left and then right, first up and then down, and reads out each relay according to the input image register and the component image register.

Common faults and solutions of Megmeet inverter Common faults and solutions of Megmeet inverter

Fault one Fault phenomenon: the leakage protection switch trips, the inverter is energized or the equipment leakage protection switch is operated during operation Solution: 1. When the inverter drives the motor, the leakage value is larger than that of the non-inverter system, and the leakage protection value of the leakage protection switch is required to be more than 150mA, ...

Megmeet welding machine - introduction to the advantages and disadvantages of carbon dioxide gas shielded welding Megmeet welding machine - introduction to the advantages and disadvantages of carbon dioxide gas shielded welding

Carbon dioxide gas shielded welding (referred to as CO2 welding) is the use of CO2 gas as the maintenance medium, during welding, CO2 gas is sprayed out through the nozzle of the welding gun, along the perimeter of the welding wire, forming a gas maintenance layer around the arc, mechanically isolating the welding arc and the molten pool from the air, and then avoiding ...

Hollysys' nationally produced SCADA system was the first to be put into application in the refined oil pipeline network of National Petroleum Pipeline Network Group Co., Ltd Hollysys' nationally produced SCADA system was the first to be put into application in the refined oil pipeline network of National Petroleum Pipeline Network Group Co., Ltd

Preface: Energy security is an overall and strategic issue related to the country's economic and social development, and is crucial to the country's prosperity and development, the improvement of people's lives, and the long-term peace and stability of society. For the first time, the 14th Five-Year Plan and the Outline of the Long-Range Objectives Through 2035 include "comprehensive energy production capacity" in the ...

Megmeet inverter - how to choose the inverter? Megmeet inverter - how to choose the inverter?

1. Understand the type of variable frequency load The correct selection of the frequency converter is very critical for the proper operation of the control system. When selecting a frequency converter, it is important to fully understand the load characteristics driven by the frequency converter. In practice, production machinery is often divided into three types: constant torque load, constant ...

The cause and treatment method of the fault code Eroc1 of Megmeet inverter The cause and treatment method of the fault code Eroc1 of Megmeet inverter

1. Overcurrent fault of inverter Fault Code: OCF. (1) Fault name: inverter overcurrent fault (2) The cause of the failure: the motor nameplate data input is incorrect: the load dragged by the motor is too heavy: the machinery is stuck; Motor stalled. (3) ...

Megmeet inverter - introduction to the control method of low-voltage inverter Megmeet inverter - introduction to the control method of low-voltage inverter

1. Sinusoidal pulse width modulation Sinusoidal Pulse Width Modulation (SPWM) is characterized by simple structure of control circuit, low cost, good hardness of mechanical characteristics, and can meet the smooth speed regulation requirements of general transmission, and has been widely used in various fields of the industry. However, this control ...

Megmeet welding machine - the application and precautions for the use of butt welding machine Megmeet welding machine - the application and precautions for the use of butt welding machine

The butt welding machine should be settled indoors, and should have a reliable grounding or zero connection, when a plurality of butt welding machines are connected to each other, the distance from each other shall not be less than 3m, and they should be connected to different corresponding power grids, and should have their own knife switches. Before welding, the pressure of the butt welder should be checked and determined.

Megmeet inverter - the role and application of the inverter control cabinet introduction Megmeet inverter - the role and application of the inverter control cabinet introduction

Inverter control cabinet (inverter electrical control cabinet / electric control cabinet / electric control box) is an electrical control cabinet developed by using inverters from Siemens, ABB, Schneider, Fujifilm, Mitsubishi, Panasonic, Delta, Shilin, Inovance and other manufacturers. According to the needs of working conditions, AC transmission can be installed in the frequency conversion cabinet.

Megmeet Inverter - Summary of Common Faults of High Voltage Inverter (1-10) Megmeet Inverter - Summary of Common Faults of High Voltage Inverter (1-10)

1。 How do you distinguish between heavy and light failures? When the fault is light, the system sends out an alarm signal, and the fault indicator flashes. When a major fault occurs, the system issues a fault indication, and the fault indicator is always on. At the same time, a command is issued to break the high voltage and close the prohibition, and the fault information and high voltage are instructed.

Solutions to common faults of Megmeet inverter (2) Solutions to common faults of Megmeet inverter (2)

Fault three Fault phenomenon: There is a rebound phenomenon when the rotation starts Solution: 1. Set the start frequency P08.02 and start frequency time P08.03 appropriately (such as P08.02=P08.03=0.5) 2. Appropriately reduce the stator resistance (P03.07) and no-load current value (P03.11 ...

Megmeet inverter – failure analysis of air compressor inverter Megmeet inverter – failure analysis of air compressor inverter

1. The voltage is unstable In the process of using the inverter air compressor, sometimes the voltage is unstable. If the voltage is unstable, a load may occur, causing the compressor to not start properly. Solution: The regulator can be adjusted in time. 2. The main ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top