Solutions to common faults of Megmeet inverter (2)

Create Date: 2024-8-30 12:03:23|Source: MEGMEET

Fault three

Fault phenomenon: There is a rebound phenomenon when the rotation starts

Solution: 1. Set the start frequency P08.02 and start frequency time P08.03 appropriately (such as P08.02=P08.03=0.5)

2. Appropriately reduce the stator resistance (P03.07) and no-load current value (P03.11)

Fault four

Fault: Inverter overcurrent fault phenomenon: Inverter panel displays Er.oc1, Er.oc2, Eroc3, (inverter acceleration, deceleration, and constant speed overcurrent)

Solution: 1. If it is a rotary frequency converter, the control mode of the motor is changed from V/F to open-loop vector, and P02.00 is set to 0.

2。 Extend acceleration and deceleration time, change P02.13.P02.14.

3. Set the starting frequency P08.02 and the starting frequency time P08.03 appropriately

4. Failure of external equipment, such as reducer, motor, etc.
Solutions to common faults of Megmeet inverter (2)

More on that
Megmeet inverters – seven areas of application for high-voltage inverters Megmeet inverters – seven areas of application for high-voltage inverters

1. Metallurgical industry - the application of high-voltage inverter in the metallurgical profession mainly includes plate and wire rod rolling mills, coilers, fans, slurry pumps, etc., with the primary intention of motor energy saving. 2. Electric power industry - China's power generation capacity ranks second in the world, second only to United States. The power profession is also changing.

Megmeet welding machine - analysis of common problems of welding machine welding Megmeet welding machine - analysis of common problems of welding machine welding

One. It is difficult to start the arc and easy to break the arc 1. Confirm that the quality of the electrode you use is good, and the poor quality electrode may not meet the requirements of high-quality welding: 2. The welding rod that has not undergone drying treatment is also not easy to arc, and causes the arc to be unstable, so that the welding defects increase, and the welding ...

Megmeet inverter - the selection principle and precautions of the inverter Megmeet inverter - the selection principle and precautions of the inverter

1. Select the inverter according to the load characteristics A: Fans and pumps are the most common loads: the requirements for the inverter are the simplest, as long as the inverter capacity is equal to the capacity of the motor (air compressors, deep water pumps, sediment pumps, and fast-changing music fountains need to increase their capacity). ...

Megmeet inverters – what are the development directions of inverter-related technologies? Megmeet inverters – what are the development directions of inverter-related technologies?

1. Intelligent network The intelligent inverter does not need to set a lot of parameters when it is used, and it has the function of fault self-diagnosis, which has high stability, high reliability and practicability. The Internet can be used to realize the linkage of multiple inverters, and even the inverter complex in the factory.

Megmeet PLC - What is the difference between PLC and servo control system Megmeet PLC - What is the difference between PLC and servo control system

1. The meaning of the representation is different: PLC is the abbreviation of planar optical waveguide (technology), the so-called planar optical waveguide, means that the optical waveguide is located in a plane. A servo control system is a feedback control system used to accurately follow or reproduce a certain process.

Megmeet PLC - how the PLC communicates with the host computer Megmeet PLC - how the PLC communicates with the host computer

The PLC communicates with the host computer, and BlandC is used to write the communication program between the host and the PLC, and the COM1 port must be initialized, the baud rate is 9600bps, and the parity check bit adopts even check, and the seven-digit valid data is used. When the computer receives the response character ACK from the PLC, it ...

Megmeet Inverter - Summary of Common Faults of High Voltage Inverter (21-32) Megmeet Inverter - Summary of Common Faults of High Voltage Inverter (21-32)

21。 The unit is overheating The radiator in the unit is equipped with a temperature switch (normally closed point), and when the temperature exceeds 85°C, the normally closed point of the temperature relay is disconnected, and the unit is overheated and faulty. Check whether the cabinet top fan is working properly, whether the unit cabinet fan switch is tripped, and whether the filter screen is blocked.

Megmeet inverter - heat dissipation design considerations for high-power high-voltage inverters Megmeet inverter - heat dissipation design considerations for high-power high-voltage inverters

(1) Select components and materials with good heat resistance and thermal stability to increase their allowable working temperature; (2) Reduce the heat generated inside the equipment (device). To this end, micropower devices, such as low-loss IGBTs, should be used more often, and the number of heat-generating components should be minimized in the circuit design.

Megmeet inverter – the difference between voltage type inverter and current type inverter Megmeet inverter – the difference between voltage type inverter and current type inverter

1. The load of the buffer inverter without functional quantity is an asynchronous motor, which is an inductive load, and in addition to transmitting active power between the intermediate DC link and the motor, there is also the exchange of reactive power. Since the power electronic switching devices cannot be stored for energy, the non-functional energy can only rely on the energy storage elements (filters).

Megmeet inverter – failure analysis of air compressor inverter Megmeet inverter – failure analysis of air compressor inverter

1. The voltage is unstable In the process of using the inverter air compressor, sometimes the voltage is unstable. If the voltage is unstable, a load may occur, causing the compressor to not start properly. Solution: The regulator can be adjusted in time. 2. The main ...

Megmeet PLC - the difference between PLC and frequency converter Megmeet PLC - the difference between PLC and frequency converter

1. The role is different A PLC (Programmable Logic Controller) is an electronic system designed for digital operations in an industrial environment. The inverter is the application of frequency conversion technology and microelectronics technology to control the AC motor by changing the frequency of the motor working power supply.

Megmeet inverter - common faults and treatment methods of high-voltage inverters Megmeet inverter - common faults and treatment methods of high-voltage inverters

1. Control through this abnormal failure The abnormal fault of the control channel is usually caused by the optical fiber communication between the sub-PWM board and the power unit board, which is generally caused by the following situations: 1. Poor contact of the optical fiber connection part or falling off of the optical fiber head; 2. Optical fiber signal transmitter/receiver ...

Megmeet PLC maintenance and processing methods Megmeet PLC maintenance and processing methods

1. CPU abnormality: When the CPU is abnormally alarmed, check the device connected to the internal line of the CPU unit. The specific method is to replace the units that may cause failures in turn, find out the faulty units, and deal with them accordingly. 2. Memory abnormality: When the memory is abnormal alarm, if it is a program ...

Megmeet Inverter - Summary of Common Faults of High Voltage Inverter (11-20) Megmeet Inverter - Summary of Common Faults of High Voltage Inverter (11-20)

11。 If the interface board does not communicate with the monitor and does not establish communication with the interface board, the interface board will reset the monitor every 5 seconds, and if the communication is not established within 3 minutes and 30 seconds, it will be judged as a serious fault. Whether the communication line is normal, check whether the terminal is correct; Whether the I/O board is working properly. Especially the work ...

Megmeet inverter - how to choose the inverter? Megmeet inverter - how to choose the inverter?

1. Understand the type of variable frequency load The correct selection of the frequency converter is very critical for the proper operation of the control system. When selecting a frequency converter, it is important to fully understand the load characteristics driven by the frequency converter. In practice, production machinery is often divided into three types: constant torque load, constant ...

Megmeet inverter - 5 precautions for the use of inverter Megmeet inverter - 5 precautions for the use of inverter

1. The circuit board inside the inverter belongs to precision electronic components, which needs to be moisture-proof and dust-proof, and the temperature and humidity are not too high, and cannot be installed on the bare wall, so the inverter should be installed in the middle of the control cabinet; The inverter should be installed vertically, and the installation should be avoided directly above and below ...

Welding methods for Megmeet hand arc welding and MIG/MAG welding Welding methods for Megmeet hand arc welding and MIG/MAG welding

1) Hand arc welding (STICK) Shielded Arc Welding (abbreviated SMAW) in English, The principle is: the welding method of generating an electric arc between the coating electrode and the base metal, and using the arc heat to melt the electrode and the base metal. The outer layer of the electrode is covered with solder, and it melts when heated.

Megmeet inverter mv600 alarm code ENOC2 Megmeet inverter mv600 alarm code ENOC2

1. If there is a sharp acceleration or deceleration, please extend the acceleration and deceleration time. 2. Avoid rapid increase in load. 3. Check whether there is a short circuit in the UVW of the motor terminal. 4. The module is damaged, and the drive circuit is damaged, resulting in an overcurrent alarm. ...

Megmeet drives – the design essentials of the drive control cabinet Megmeet drives – the design essentials of the drive control cabinet

The inverter should be installed inside the control cabinet, and the design of the control cabinet should pay attention to the following issues: 1. Wiring specification of inverter The signal line and the power line must be separated: When using an analog signal to remotely control the inverter, in order to reduce the interference of the analog signal to equipment such as the inverter, ...

Megmeet drives – what are the basic requirements for regular replacement of drive components? Megmeet drives – what are the basic requirements for regular replacement of drive components?

1. It is necessary to figure out the basic parameters and shape of the device that needs to be replaced. The basic parameters include the rated operating current, the capacitance of the capacitor, the resistance value of the resistor, the value of the GTR Darlington device (current amplification factor), the switching characteristics of the IGBT (including IPM) device, and the saturation voltage ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top