Fault one
Fault phenomenon: the leakage protection switch trips, the inverter is energized or the equipment leakage protection switch is operated during operation
Solution: 1. When the inverter drives the motor, the leakage value is larger than that of the non-inverter system, and the leakage protection value of the leakage protection switch is required to be more than 150mA, and the leakage protector with the action delay value is more than 1S.
2. Adjust the inverter parameter P12.02, the lower the value, the smaller the leakage current, adjustable 1K.
Common faults and solutions of Megmeet inverter
Fault two
Fault phenomenon: return to the frequency converter control, the boom rebounds when the machine is stopped
Solution: The main reason for this situation is that the shutdown is relatively fast, and the distortion accumulated by the tower body is naturally released, so it is necessary to slow down the deceleration time, but it is not useful to shorten the deceleration time of the inverter.
Check whether the eddy current setting is normal, generally the corresponding eddy current value of each gear is 12-10; 8-6;5-4; 3-2 is more appropriate.
After the eddy current verification, if it still rebounds, the frequency of the inverter shutdown P08.07 can be adjusted up, which is currently 3.5Hz by default, and can be adjusted to 7Hz.
|
More on that
|
Common faults and solutions of Megmeet inverter
Fault one
Fault phenomenon: the leakage protection switch trips, the inverter is energized or the equipment leakage protection switch is operated during operation
Solution: 1. When the inverter drives the motor, the leakage value is larger than that of the non-inverter system, and the leakage protection value of the leakage protection switch is required to be more than 150mA, ...
|
|
Megmeet welding machine - the application and protection of AC arc welding machine should pay attention to
What aspects should be paid attention to in the application and protection of AC arc welding machine:
(1) It should be used according to the additional welding current and load continuation rate of the welding machine, and should not be overloaded.
(2) The welding machine is not allowed to be short-circuited for a long time.
(3) The regulating current should be operated at no load.
(4) ...
|
|
Megmeet inverter - the daily maintenance and overhaul of the inverter
1. Regularly dust the inverter, focusing on the rectifier cabinet, inverter cabinet and control cabinet, if necessary, the rectifier module, inverter module and the circuit board in the control cabinet can be removed for dust removal. Whether the lower air inlet and upper air outlet of the inverter are dusty or blocked due to excessive dust. The inverter is due to the ...
|
|
Megmeet inverter - high-voltage inverter selection considerations
First, the disadvantages
Choosing too high a voltage level results in too high an investment and a long payback period. With the increase of the voltage level, the insulation of the motor must be improved, so that the price of the motor increases. The increase of voltage level increases the number of series connections of power semiconductor devices in the inverter, and the cost rises.
...
|
|
Megmeet PLC - What is the difference between PLC and servo control system
1. The meaning of the representation is different:
PLC is the abbreviation of planar optical waveguide (technology), the so-called planar optical waveguide, means that the optical waveguide is located in a plane.
A servo control system is a feedback control system used to accurately follow or reproduce a certain process.
|
|
Megmeet new energy vehicle PEU intelligent manufacturing production line was put into use
Zhuzhou Lihui Technology Co., Ltd., a subsidiary of Megmit, has put into use a new production line of PEU intelligent production of new energy cars, leading the wave of intelligent production of PEU in the key "three electric" components of domestic new energy cars.
Zhuzhou Lihui Technology Co., Ltd. production workshop, a new ...
|
|
Common faults of Megmeet drives and how to deal with them
1. When the oscilloscope looks at the current monitoring output of the driver, it finds that it is all noisy and cannot be read
Cause: The current monitoring output is not blocked from the AC power supply (transformer).
Solution: You can use a DC voltmeter to detect and investigate.
2. Servo motor high speed ...
|
|
Megmeet PLC – The importance of PLC industrial gateways
1. Realize remote control of industrial field equipment;
2. The PLC industrial gateway realizes remote upgrade of equipment firmware, downloads the program, and can flexibly access various equipment management platforms;
3. Realize remote control of industrial site touch screen and remote mapping of configuration screens;
4. PLC industry ...
|
|
Megmeet inverter - what are the main aspects of the development of inverter in the future?
1. Intelligent network
The intelligent inverter does not need to set a lot of parameters when it is used, and it has the function of fault self-diagnosis, which has high stability, high reliability and practicability. The Internet can be used to realize the linkage of multiple inverters, and even the inverter complex in the factory.
|
|
Megmeet inverter - precautions for inverters at high temperatures
1. Carefully monitor and record the display parameters on the man-machine interface of the inverter, and reflect the abnormality immediately;
2. Carefully monitor and record the ambient temperature of the frequency conversion room, and the ambient temperature should be between -5 °C and 40 °C. The temperature rise of the phase-shifting transformer should not exceed 130°C;
3. Summer ...
|
|
Megmeet PLC - an introduction to the classification of PLC
There are many types of PLC products, and their specifications and performance also vary. PLCs are usually classified according to their different structural forms, differences in functions, and the number of I/O points.
2.1 Classification by structural form
According to the structural form of PLC, PLC can be divided into whole ...
|
|
Megmeet PLC - Introduction to the basic structure of PLC controller
1. Power supply
The power supply of the PLC plays a very important role in the whole system. It can't work properly without a good and reliable power supply system, so PLC manufacturers also attach great importance to the design and manufacture of power supplies. General AC voltage fluctuations are +10% (+15%) ...
|
|
Megmeet PLC – the maintenance steps of the PLC control cabinet
1. Data backup
When carrying out maintenance, we must cut off the power, data backup between power outages is an important link, for the data that needs to be archived for a long time, you can back up the historical trend data to the mobile hard disk, and then turn off the Windows-based operating system (Note...
|
|
Welding methods for Megmeet hand arc welding and MIG/MAG welding
1) Hand arc welding (STICK)
Shielded Arc Welding (abbreviated SMAW) in English,
The principle is: the welding method of generating an electric arc between the coating electrode and the base metal, and using the arc heat to melt the electrode and the base metal. The outer layer of the electrode is covered with solder, and it melts when heated.
|
|
Megmeet PLC - the installation method and functional requirements of the PLC
Installation:
The installation mode of PLC system is divided into centralized, remote I/O and distributed with multiple PLC networking.
Centralized does not need to set up the drive remote I/O hardware, the system response is fast, and the cost is low; Remote I/O is suitable for large systems with a range of ...
|
|
Megmeet PLC - What are the functions of the PLC gateway?
1. PLC industrial gateway has rich interfaces and is easy to deploy
It supports 4G, 3G, PPPOE, Wi-Fi network, digital IO input and output, and serial terminal communication, providing different access solutions for different applications.
2. Intelligent analysis and efficient access
Inline protocol analysis ...
|
|
Megmeet inverter - heating noise harmonic problems in inverter applications and countermeasures
First, some problems in the application of frequency converter
1.1
Harmonic problems
The devices that play a switching role in the main circuit of the inverter must generate harmonics in the process of turning on and off the circuit. The lower harmonics usually have a greater impact on the motor load, causing torque ripple; And the higher ...
|
|
Megmeet inverter - introduction to the classification of inverters
1. Classified according to the input voltage level
According to the input voltage level, the inverter can be divided into low-voltage inverter and high-voltage inverter, and the low-voltage inverter is common in China with single-phase 220 V inverter, three-phase 220 V inverter, and i-phase 380 V inverter. High-voltage inverters are commonly used in 6 kV, 10 kV transformers.
|
|
Megmeet PLC - how the PLC communicates with the host computer
The PLC communicates with the host computer, and BlandC is used to write the communication program between the host and the PLC, and the COM1 port must be initialized, the baud rate is 9600bps, and the parity check bit adopts even check, and the seven-digit valid data is used.
When the computer receives the response character ACK from the PLC, it ...
|
|
Megmeet PLC – What are the advantages of PLC compared to relays?
(1) In terms of control method: PLC adopts a program to achieve control, which is easy to change or increase the control requirements, and the contact points of PLC are unlimited;
(2) In terms of working mode: PLC adopts serial working mode to improve the anti-interference ability of the system;
(3) Control speed: PLC ...
|
|