1. Thermostat contact contact failure

Poor contact of the thermostat contacts will cause the compressor to not operate properly. If the contacts are sticky, the compressor will fail without downtime. For this, you can use a small screwdriver to open the metal shell of the thermostat, and then use a fine abrasive cloth to polish the surface of the contacts. The on/off of the thermostat is easy to measure with a multimeter barrier, and the thermostat contacts are normally closed at room temperature, and when the temperature drops to a certain value, the contacts become normally open.

2. Thermostat leakage failure

When the thermostat inside the thermostat leaks, the contacts will be disconnected and the compressor will stop. To determine whether there is a leak, you can use a towel to heat the temperature bag, adjust the temperature control knob to the lowest gear, and use a multimeter to measure that the contact is closed. If the contacts are blocked, the thermostat has leaked.

3. Large temperature control error

If the parameters of the thermostat are not suitable or the debugging is not accurate, it will cause a large temperature error of the thermostat, so that the air conditioner will not stop or frequently open and stop faults, at this time, the temperature difference adjustment screw of the thermostat can be readjusted, and the new thermostat can also be replaced.
RHK thermostat - common faults and maintenance methods of thermostats

More on that
RKC thermostat – the correct way to adjust the thermostat RKC thermostat – the correct way to adjust the thermostat

1. Set temperature: Press the SET button to set or view the temperature set point. Press the SET key digital tube character start flashing, indicating that the appearance has entered the setting state, press the △ key to increase the set value, press the ▽ key to decrease the set value, press and hold the △ key or ▽ key The data will change rapidly, press the SET key again The appearance will return ...

Where you need to pay attention to the wiring of the RRKC thermostat Where you need to pay attention to the wiring of the RRKC thermostat

1. For thermocouple input, the corresponding compensation wire should be used. 2. RTD input, 3 wires with low resistance and no difference should be used. 3. The input signal line should be far away from the power line of the instrument. Power supply and load lines to avoid noise interference. 4. Instrument power cord ...

RHK thermostat – a rapid detection method for common air conditioner thermostats RHK thermostat – a rapid detection method for common air conditioner thermostats

1. Bellows or diaphragm air conditioner thermostat 1. Fault phenomenon: poor contact or burning, resulting in the circuit can not be connected; The frequent action of the contact arc and sticking causes the circuit to be unbreakable; The thermostat in the temperature sensing chamber leaks, causing the contact to fail to operate and lose control. ...

RRKC Thermostat – Questions and Precautions About Thermostat Expansion Modules RRKC Thermostat – Questions and Precautions About Thermostat Expansion Modules

1. Under what circumstances should I use a thermostat to expand the module? The gradual development of the heating field is now very well recognized, and more and more users have begun to install electric heating, of course, when installing electric heating for users, they have also encountered some headaches. For example, a large area ...

RK Thermostat - Part of the LCD shows the status quo of floor heating thermostats RK Thermostat - Part of the LCD shows the status quo of floor heating thermostats

1) The LCD interface is too large or the display symbols are not proportional or standard. 2) The terminal blocks or circuits (components) that control the output cannot withstand large currents. 3) The cable of the external sensor (ground probe) is a thin and flexible wire, which cannot be inserted into the embedded pipe, and it is also a hidden danger for future maintenance. ...

RLC Thermostat – How to use a smart temperature controller RLC Thermostat – How to use a smart temperature controller

1. Set temperature: press and hold the SET key, at this time the tube character begins to flash, proving that the instrument has entered the set state, increase the up button, decrease the down button, and press and hold the up and down buttons to quickly change, when the desired temperature is reached, then press the SET button The instrument is set. 2. Return control: press SET ...

RLC thermostat - common faults and solutions of intelligent temperature controllers RLC thermostat - common faults and solutions of intelligent temperature controllers

1. Heating for a period of time, the temperature does not change. Displays the ambient temperature of the site at all times (e.g. room temperature 25°C) In case of such failures, first check whether the SV value setting value is set, whether the instrument OUT indicator is lit, and whether the No. 3 and 4 terminals of the "multimeter" measuring instrument have 12VDC output.

RRC thermostat - introduction to the working principle and classification of electronic thermostats RRC thermostat - introduction to the working principle and classification of electronic thermostats

Principle of electronic thermostat: The electronic temperature controller (resistive type) is measured by the method of resistance temperature sensing, and generally uses platinum wire, copper wire, tungsten wire and semiconductor (thermistor, etc.) as the temperature measurement resistor, which has its own advantages and disadvantages. Household Air Conditioner Temperature Controller ...

RKC thermostat Digital display controller parameter setting method RKC thermostat Digital display controller parameter setting method

A digital display controller is a simple controller with indication, control, remote transmission and alarm functions. As a secondary instrument commonly used in sensors, it is very important to operate and use it correctly. Applications such as level control, temperature control, pressure control and parameter value display of measured variables. ...

Initialization parameter setting of the rkc thermostat Initialization parameter setting of the rkc thermostat

1. Press the ISET) button for 2 seconds to enter the parameter setting mode, press ISET until "LCK" is displayed, press the [] key to move the cursor to the thousands, and press the [] button to change the number of thousands from "0" to "1" to display "1000" to unlock. 2. Press the ISET button for 3 seconds to return to SV/PV display mode 3. Press [SET]+ ...

RKC thermostat REX-C400 model settings and parameter instructions RKC thermostat REX-C400 model settings and parameter instructions

  Japan RIKA RKCREX-C400 temperature controller product introduction. REX-C400 Digital Temperature Control Controller, RKCPID Temperature Controller, Temperature Controller, (SSR Output) + Type K Thermocouple + *Large 40ASSR Relay. 1. Dual display set temperature and working ...

RHK thermostat - the use of electronic thermostat and its classification introduction RHK thermostat - the use of electronic thermostat and its classification introduction

First, the use of electronic temperature controller The electronic temperature controller (resistive type) is measured by the method of resistance temperature sensing, and generally uses platinum wire, copper wire, tungsten wire and semiconductor (thermistor, etc.) as the temperature measurement resistor, and these resistors have their own advantages and points. Home Air Conditioner ...

RLC thermostat – the wiring method of the thermostat RLC thermostat – the wiring method of the thermostat

1. Prepare the thermostat, wires, and thermal resistance, and print out the wiring diagram of the thermostat 2. Use wire strippers to strip off the wire skin, use crimping pliers, and press the wire end to the cold-pressed terminal. 3. Connect the 220V power supply to the inlet terminal of the thermostat, and connect the thermal resistance to the thermostat ...

RKC Level Gauge – The correct way to use the float level gauge RKC Level Gauge – The correct way to use the float level gauge

(1) Before use, first check whether the level gauge is within the verification cycle, otherwise, it should be calibrated, and replaced in time if it is unqualified. (2) The sensor should be installed horizontally, and the length of the lower entry should meet the technical requirements. (3) The connection between the sensor and the explosion-proof junction box should be tightened and tightened.

RKC Thermostat How to properly select and use a pressure sensor RKC Thermostat How to properly select and use a pressure sensor

 High-temperature melt pressure sensors, transmitters, and high-temperature melt pressure gauges are special equipment in extrusion processing. On the production line, melt pressure sensors play an important role in improving melt quality, increasing production safety and protecting production equipment. Use...

RLC thermostat - a detailed explanation of dry-type transformer thermostats RLC thermostat - a detailed explanation of dry-type transformer thermostats

The working principle of dry-type transformer thermostats The dry-type transformer temperature controller is a new generation of controller designed for the safe operation of dry-type transformers. The controller adopts single-chip microcomputer technology, and uses three platinum thermal resistors embedded in the three-phase winding of the dry-type transformer to detect and display the transformer.

RK thermostat - the use and adjustment of temperature control instruments RK thermostat - the use and adjustment of temperature control instruments

1. Set temperature: Press the SET button to set or check the temperature set point. Press the SET button at the beginning of the digital tube character flashing, indicating that the appearance has entered the setting state, press the △ key to add the set value, press the v key to decrease the setting value, press and hold the △ key or √ key The data will change rapidly, press the SET key again ...

RKC thermostat wiring needs to pay attention to RKC thermostat wiring needs to pay attention to

Wiring Notes: 1. For thermocouple input, the corresponding compensation wire should be used. 2. RTD input, 3 wires with low resistance and no difference should be used. 3. The input signal line should be far away from the power line of the instrument. Power supply and load lines to avoid noise interference. ...

RLC thermostat – what is the difference between a mechanical thermostat and an electronic thermostat RLC thermostat – what is the difference between a mechanical thermostat and an electronic thermostat

Mechanical thermostat mainly refers to a temperature control method that adjusts refrigeration by rotating the button, with an expanding thermostat, which will automatically expand and contract according to the change of temperature, so as to control the power supply, the most primitive type, and the structure is relatively simple. Advantages of mechanical thermostats: ...

How to set the parameters of the RKC fb900 thermostat How to set the parameters of the RKC fb900 thermostat

Model definition FB90②③*④4⑤⑥⑦⑧⑨-0( CODE 8N-4*4NN5/A1-F801/Y control "(1)(2)" indicates Output 1 and Output 2 classes M: Relay output V: Voltage pulse output 5: 0-10V 8: 4-20mAN: No output “ ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top