RLC thermostat – what is the difference between a mechanical thermostat and an electronic thermostat

Create Date: 2024-8-30 12:03:23|Source: RKC

Mechanical thermostat mainly refers to a temperature control method that adjusts refrigeration by rotating the button, with an expanding thermostat, which will automatically expand and contract according to the change of temperature, so as to control the power supply, the most primitive type, and the structure is relatively simple.

Advantages of mechanical thermostats:

(1) The structure is simple, the price is cheap, the cost is low, and the price of the mechanical temperature control freezer is affordable.

(2) Due to the simple structure, the thermostat is strong and durable, with high stability, not easy to fail, and at the same time, it is relatively simple and convenient to maintain, and the cost is low.

(3) No electricity is required during operation.

Disadvantages of mechanical thermostats:

(1) The accuracy of temperature control is inferior to that of the computer temperature control system, due to the inaccurate temperature control, the temperature in the freezer is unstable, and the temperature cannot be controlled independently by refrigeration and freezing.

(2) The mechanical temperature control freezer cannot realize the real independent refrigeration system, the preservation effect is not good enough, and there is the problem of food flavor.

(3) The convenience of operation is poor, and the freezer needs to be opened to complete the operation.

Electronic thermostat mainly refers to a temperature control mode that adjusts refrigeration through microcomputer control and electronic display display, and controls the power supply according to the temperature sensing function and thermal resistance timing, which is a more advanced temperature control mode with a complex structure.

Advantages of computerized thermostats:

(1) The temperature can be controlled independently, and the specific temperature can be set, and the temperature control is more accurate, which can make the temperature of the freezer very stable.

(2) The computerized temperature-controlled freezer can realize an independent refrigeration system, so that the refrigeration effect of the freezer is better, the preservation effect is also better, and the problem of food cross-smell is eliminated.

(3) The LCD display is clear and clear, the display is very intuitive, and the operation is relatively simple.

(4) Powerful, fully automatic control, one table and multiple control.

Disadvantages of computerized thermostats:

(1) The price is relatively expensive and the cost is high, resulting in a high price of the freezer.

(2) Due to the complex structure, it is difficult to maintain faults and the cost is high.

(3) Independent power supply is required.
RLC thermostat – what is the difference between a mechanical thermostat and an electronic thermostat


More on that
RKG thermostat – how the temperature controller sets the parameters RKG thermostat – how the temperature controller sets the parameters

1. Lower limit deviation alarm setting: press the SET key to select and display "SLP", the green display screen displays the value of the parameter, and select the shift, increment, and decrement keys to set or modify the parameter. This parameter indicates the difference between the alarm point and the master setpoint. 2. The upper limit deviation alarm is set ...

RKC converters – what are the functions of converters? RKC converters – what are the functions of converters?

1. Power conversion: convert the voltage (rated 100V) and current (rated 5A or 1A) of the transformer into voltage (several volts) to meet the requirements of weak current components. 2. Isolation: current, secondary side security, and work grounding are used to ensure the safety of people and equipment, while weak current ...

RKC level gauge - buoy level gauge structure composition RKC level gauge - buoy level gauge structure composition

The level gauge is composed of five parts: float, traction cable, guide pulley, hammer pointer, display ruler or magnetic flap. 1. Float: The float is welded with two stainless steel (or carbon steel) fasting cones and one stainless steel (or carbon steel) fasting cylinder.

RKC Level Gauge – The correct maintenance method for float level gauges RKC Level Gauge – The correct maintenance method for float level gauges

(1) After 6 months to 1 year of operation, the sensor should be visually inspected and routinely calibrated. (2) Regularly check whether the sensor is bent and deformed by external force to avoid ball jamming. (3) Regularly check whether the magnetic induction switch element of the sensor is aging and failing, ...

RLC thermostat - introduction to the performance characteristics of intelligent digital display controller RLC thermostat - introduction to the performance characteristics of intelligent digital display controller

1. The special integrated instrument chip has more reliable anti-interference and stability. 2. Signal input, which can be matched with commonly used thermal signals through menu settings. 3. The display range, transmission output range, alarm value and alarm mode can be modified online. 4. Soft ...

RHK thermostat - the thermostat shows the reasons for the deviation between the temperature and the actual temperature and the solution RHK thermostat - the thermostat shows the reasons for the deviation between the temperature and the actual temperature and the solution

The thermostat shows a nonlinear relationship between the temperature and the actual temperature deviation: (1) The input type of the thermostat is selected incorrectly; (2) There is no calibration or calibration error in the analog input; (3) There is interference in the thermostat; (4) There is interference with thermocouples; (5) The use of quality is not ...

RRKC thermostat – the correct way to set up the thermostat RRKC thermostat – the correct way to set up the thermostat

Press the SET button to set or view the temperature set point, press the SET key digital tube characters to start flashing, indicating that the instrument has entered the setting state, press the △ key to increase the set value, press the ▽ key to decrease the set value, press and hold the △ key or ▽ key The data will change rapidly, press the SET key again The instrument returns to normal working condition ...

RK thermostat - classification and precautions for use of central air conditioning thermostat RK thermostat - classification and precautions for use of central air conditioning thermostat

1. The principle of central air conditioning thermostat Mechanical thermostats can be divided into vapor pressure thermostats, liquid expansion thermostats, gas adsorption thermostats and metal expansion thermostats. Among them, the vapor pressure thermostat is divided into inflatable type, liquid-gas mixed type and liquid-filled type. Domestic...

What are the solutions to the failure of the RRKC thermostat - the sudden thermostat? What are the solutions to the failure of the RRKC thermostat - the sudden thermostat?

1. The cleanliness and finish of the contact surface have a great impact on the working condition of the contact. When the surface of the contact is rough or there is excess material on the contact, it is easy to cause arcing and reduce the life of the contact. Therefore, the parts cleaning process should be improved to eliminate excess materials; Increasing the process of screening excess materials, ...

RHK thermostats – an introduction to the classification of displays RHK thermostats – an introduction to the classification of displays

(1) Categorize by display color 1. Monochrome display There are two types of displays: multi-grayscale monochrome display and VGA multi-frequency monochrome display. These displays are small, lightweight, clear and inexpensive, making them suitable for highly mobile workplaces. 2. Color ...

RKC thermostat - what are the anti-interference measures of the instrument? RKC thermostat - what are the anti-interference measures of the instrument?

1. Electromagnetic induction (refers to the coupling of magnetism). There is a strong alternating magnetic field in the surrounding space of high-power transformers, AC motors, high-current power grids, etc., and the closed loop formed by the lines of the control system (detection, transmission, conversion, regulation, calculation, execution, auxiliary, display, etc.) is located in the ...

RKC Level Gauges – Precautions for Level Gauges RKC Level Gauges – Precautions for Level Gauges

The correct selection of the level gauge can ensure the better use of the level gauge. What kind of level gauge should be selected according to the physical and chemical properties of the fluid medium to be measured? What is the diameter of the level gauge, the flow range, the lining material, the electrode material, and the output current? can adapt to the ...

Common faults and failure analysis of RTC thermostats Common faults and failure analysis of RTC thermostats

1. The power indication is normal, but the temperature controller has no screen display. Most of this fault is caused by the heating of the voltage regulator element (7805 or 7812) on the thermostat during long-term use, which leads to the breakpoint of the solder joint, and sometimes it is caused by the phenomenon of virtual soldering at the factory, and the main re-soldering can be done. 2. Temperature controller ...

What are the characteristics of RLC thermostats – mechanical thermostats? What are the characteristics of RLC thermostats – mechanical thermostats?

1. Used to control fan coil unit, electric valve, damper and other equipment; 2. The switch adopts toggle type, which feels comfortable and has a long life; 3. Set the temperature by twisting (the temperature range can be limited); 4. The thermostat can be installed directly on the wall or on the standard junction box; ...

Difference Between Thermocouple and RTD Difference Between Thermocouple and RTD

In temperature measurement, thermocouples and RTDs are both contact temperature measurements, and although they both measure the temperature of an object, their principles and characteristics are different. This article first introduces thermocouples, which are widely used in temperature measurement temperature control devices.

Common faults in the use of RKC thermostat Pt100 RTD Common faults in the use of RKC thermostat Pt100 RTD

  PT100 RTD is a platinum RTD, which can be regarded as a more commonly used thermometer in the range of medium and low temperatures, and it has a wide range of uses, including medical, electric, industrial production, thermometers and other high-precision thermometers. But due to the range of use ...

RHK thermostat – a rapid detection method for common air conditioner thermostats RHK thermostat – a rapid detection method for common air conditioner thermostats

1. Bellows or diaphragm air conditioner thermostat 1. Fault phenomenon: poor contact or burning, resulting in the circuit can not be connected; The frequent action of the contact arc and sticking causes the circuit to be unbreakable; The thermostat in the temperature sensing chamber leaks, causing the contact to fail to operate and lose control. ...

RLC Thermostat - Fault and Troubleshooting of Vapor Pressure Temperature Controller RLC Thermostat - Fault and Troubleshooting of Vapor Pressure Temperature Controller

Faulting and troubleshooting of vapor pressure temperature controllers (1) Common faults and common faults of the vapor pressure type temperature controller include contact burning or adhesion, failure of the mechanical transmission mechanism and leakage of temperature sensor in the temperature sensing tube. Its detection method is: put the thermostat knob in a parking position, and use ...

RKC Level Gauge - the principle of the selection of float level gauges RKC Level Gauge - the principle of the selection of float level gauges

The float level gauge is widely used, mainly used in petroleum processing, food processing, chemical industry, water treatment, manufacturing, electric power, papermaking, metallurgy, ships and boilers and other industrial automation processes to measure and control the level. 1. Pay attention to the specific working conditions. As introduced ...

Wiring method of the RKG thermostat Wiring method of the RKG thermostat

Take CD901 as an example, L(1) pin to 220 volt live wire, N(2) pin 220 volt neutral wire, 3,4 pins for the first output, 5,6 pins for the second output, 7, 8, 9 pins are alarm output, Finally, the three pins are connected to thermocouples or PT100 ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top