RKC thermostat wiring needs to pay attention to

Create Date: 2024-8-30 12:03:23|Source: RKC

Wiring Notes:

1. For thermocouple input, the corresponding compensation wire should be used.

2. RTD input, 3 wires with low resistance and no difference should be used.

3. The input signal line should be far away from the power line of the instrument. Power supply and load lines to avoid noise interference.

4. The power cord of the instrument is usually interfered with by the power supply.

When the instrument compensates for external noise interference, a noise filter must be used.

? Shorten the twist length of the power cord, the shorter the distance, the more noise will be reduced.

? Install a noise filter on the instrument panel and ground it, and reduce the wiring distance between the noise filter output and the instrument's power terminal.

? Do not install a fuse or switch on the output of the filter, as this will reduce the effectiveness of the filter.

5. The wiring should conform to the national standard of each country, and the power cord should use 600v PVC insulated wire) (JIsc3307)

6. After the power is turned on, the instrument output by the relay needs 5-6 seconds of preparation time, if used for external connection loop and other signals, please use the delay relay at the same time.

7. This instrument does not have a power switch and a fuse, if necessary, it can be installed Recommended fuse specifications: rated voltage 250V rated current 1A Fuse model: delay fuse

8. Do not overtighten the terminal screws. In addition, use a suitable terminal screw lug (screw model M3*6, recommended torque: 0.4Nm)
RKC thermostat wiring needs to pay attention to

More on that
RLC thermostat - common faults of temperature controllers and solutions RLC thermostat - common faults of temperature controllers and solutions

Fault 1: The device does not display after powering on Solution(s): First of all, check whether the terminals of the device have been connected to the neutral live wire, and make sure that the neutral live power supply can work normally. Then start to check whether the cable between the LCD motherboard and the device drive power supply is ...

RLC Thermostat – Instructions for installation and use of pop-up thermostats RLC Thermostat – Instructions for installation and use of pop-up thermostats

1. Grounding method: It is connected to the grounding metal parts of the equipment through the metal cover of the thermostat. 2. The thermostat should work in the general indoor environment where the relative humidity of the air is not more than 90%, and there are no corrosive gases, flammable gases and conductive dust. 3. The thermostat adopts contact ...

What should I pay attention to when setting up my RKC thermostat? What should I pay attention to when setting up my RKC thermostat?

Wiring Warning: If the instrument fails or an error occurs, which can cause a system failure, an external protection circuit is installed to prevent such accidents: In order to prevent damage or failure of the instrument, choose an appropriate fuse to protect the power cord and input and output lines from strong power shocks. Power supply ...

RKC Thermostat – What are the common faults of thermostats? RKC Thermostat – What are the common faults of thermostats?

1. There is no manifestation when the power is on. For this kind of problem, first confirm whether the power supply is there and whether the power supply matches the power supply required by the thermostat, and then check whether the wiring is strong. The problem is still there, then it is the problem of the thermostat itself. 2. There is a manifestation, and the manipulation makes mistakes. The first thing to look at this kind of problem is to look at the control ...

RKC Level Gauge – Some installation requirements for pontoon level gauges RKC Level Gauge – Some installation requirements for pontoon level gauges

1. The installation of the level gauge must be vertical to ensure that the inner pontoon can move up and down freely in the pipe body. 2. Install a shut-off valve between the container and the liquid level gauge to clean and overhaul the liquid level timing to cut off the material. 3. No magnets are allowed to approach around the main body of the pontoon level gauge, otherwise ...

Parameter setting operation of RLC temperature control table CH402 Parameter setting operation of RLC temperature control table CH402

Model: CH402FS01-8*HN (for PECVD temperature control) 1) Single press SET: SV can be set (set temperature manually) 2) Press and hold the SET button for 2 seconds, ALI=1000 (absolute alarm temperature setting) and then press the SET button, ATU=1 (self-defining, self-interpreting a set of PID parameters) to exit ...

RKC Thermostat How to properly select and use a pressure sensor RKC Thermostat How to properly select and use a pressure sensor

 High-temperature melt pressure sensors, transmitters, and high-temperature melt pressure gauges are special equipment in extrusion processing. On the production line, melt pressure sensors play an important role in improving melt quality, increasing production safety and protecting production equipment. Use...

RKC Level Gauge – The structure of a float level gauge RKC Level Gauge – The structure of a float level gauge

(1) For the indicator, also known as the display panel, the indicator plays the role of local display, convenient for long-distance observation of the actual situation of the liquid level, the indicator is generally bundled with the pontoon, easy to install. (2) It is a magnetic float, which is located in the pontoon and is in direct contact with the liquid to be measured, ...

RKC Thermostats – How to Choose a Thermocouple? RKC Thermostats – How to Choose a Thermocouple?

The selection of thermocouples should be based on comprehensive considerations such as the operating temperature range, the required accuracy, the operating atmosphere, the performance of the measured object, the response time and the economic benefits. 1. Selection of measurement accuracy and temperature measurement range 1) The operating temperature is 1300-1800°C, and the accuracy is required to be more accurate than ...

RKC thermostat operation attention and its main features RKC thermostat operation attention and its main features

RKC thermostat operation attention · Clean the instrument only after the power is off; · Please use a soft cloth or cotton paper to remove stains on the monitor; · The display is easy to be scratched, it is forbidden to use hard object to operate the panel buttons, otherwise the keys will be damaged or scratched.   Key features: ...

RKC Level Gauge – How to install a buoy level gauge RKC Level Gauge – How to install a buoy level gauge

1. Welding and installation of the lower support of the guide wire: determine the position at the bottom of the container according to the requirements of the movement direction of the float of the level gauge, and weld or rivet the lower support of the fixed guide wire. If the equipment does not have welding conditions, the heavy anchor fixing method can be used to fix the guide wire under the support. For example, the liquid level wave in the container ...

RK thermostat - common problems and solutions of electric floor heating stand-alone thermostat RK thermostat - common problems and solutions of electric floor heating stand-alone thermostat

Fault 1: The thermostat does not turn on (the screen does not display) Analyze the causes 1. Wrong wiring; 2. The voltage of the input terminal is not enough or the input terminal is damaged by the empty leakage guarantee; 3. Whether the cable between the panel and the power board is broken or plugged incorrectly; 4. Load short circuit or broken ...

Technical characteristics of the RKC thermostat Technical characteristics of the RKC thermostat

The core control algorithm of the thermostat is PID control, P (Proportional) + I (Integral) integral + D (Differential) differential control. In addition to the traditional PID control algorithm, RKC also has ON-OFF control, self-tuning parameter control, adaptive parameter control and other algorithms, temperature control ...

Introduction to the functions of the RKC temperature control meter Introduction to the functions of the RKC temperature control meter

(1) RH400 size: 48*96, depth 60, about 250g Details: ●A variety of input types are available: 1) Thermocouples: K, J, R, S, B, E, N, T, W5RE/W6RE, PL‖, U, L 2) Temperature measurement RTD input: PT100, JPT100...

RKC Level Gauge - Preservation and storage of float level gauges in daily use RKC Level Gauge - Preservation and storage of float level gauges in daily use

1. To avoid damage to the instrument, pay attention to the correct protection method: in order to ensure the accuracy of the instrument and avoid damage to the instrument, try not to use the protection instrument of isolator or other isolation devices. If you have to do it, you should also pay attention to the careful selection, determine the isolation solution, and wash the isolation film correctly, ...

RK thermostat - classification and precautions for use of central air conditioning thermostat RK thermostat - classification and precautions for use of central air conditioning thermostat

1. The principle of central air conditioning thermostat Mechanical thermostats can be divided into vapor pressure thermostats, liquid expansion thermostats, gas adsorption thermostats and metal expansion thermostats. Among them, the vapor pressure thermostat is divided into inflatable type, liquid-gas mixed type and liquid-filled type. Domestic...

What are the precautions for the installation of the RKG thermostat? What are the precautions for the installation of the RKG thermostat?

1) For RTD input, 3 wires with low resistance and no difference should be used.   2) The input signal line should be far away from the power line of the instrument. Power supply and load lines to prevent noise disturbances.   3) The power cord of the instrument is generally disturbed by the power supply.   4) Instrument complement ...

What problems are easy to encounter in the use of RKCPT100 temperature sensor probes? What problems are easy to encounter in the use of RKCPT100 temperature sensor probes?

What problems are easy to encounter in the use of PT100 temperature sensor probes? 1. Is the output signal unstable? A: Maybe it's the temperature instability of the temperature source itself, or the problem of on-site disturbance. 2. Is there a big error in the output of the transmitter? Answer: This ...

What should I pay attention to when wiring the RKG thermostat? What should I pay attention to when wiring the RKG thermostat?

1. For thermocouple input, the corresponding compensation wire should be used. 2. For RTD input, 3 wires with low resistance and no difference should be used 3. The input signal line should be far away from the power line of the instrument. Power supply and load lines to avoid noise interference 4. The instrument power cord is usually ...

RKC thermostat Digital display controller parameter setting method RKC thermostat Digital display controller parameter setting method

A digital display controller is a simple controller with indication, control, remote transmission and alarm functions. As a secondary instrument commonly used in sensors, it is very important to operate and use it correctly. Applications such as level control, temperature control, pressure control and parameter value display of measured variables. ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top