RK Thermostat - Part of the LCD shows the status quo of floor heating thermostats

Create Date: 2024-8-30 12:03:23|Source: RKC

1) The LCD interface is too large or the display symbols are not proportional or standard.

2) The terminal blocks or circuits (components) that control the output cannot withstand large currents.

3) The cable of the external sensor (ground probe) is a thin and flexible wire, which cannot be inserted into the embedded pipe, and it is also a hidden danger for future maintenance.

4) The control logic does not match the requirements of the floor heating system, resulting in the function is not dedicated and practical.

5) There is only one temperature control circuit, which cannot achieve "internal control and outer limit". That is, it is impossible to measure and control the air temperature in the room, and at the same time, it is limited to the ground temperature.

6) The overall shape is thin and the structure is unreasonable. The failure rate of the initial adjustment of the installation is higher, and the long-term stability is worse.
RK Thermostat - Part of the LCD shows the status quo of floor heating thermostats

More on that
RRKC thermostat - common faults and solutions of stand-alone thermostats RRKC thermostat - common faults and solutions of stand-alone thermostats

Fault 1: The thermostat does not turn on (does not light up) Analyze the causes 1. Wrong wiring 2. The voltage of the input terminal is not enough or the input terminal is damaged by empty opening and leakage 3. Whether the cable between the panel and the power board is broken or plugged incorrectly 4. Load short circuit or open circuit, probe ...

What are the solutions to the failure of the RRKC thermostat - the sudden thermostat? What are the solutions to the failure of the RRKC thermostat - the sudden thermostat?

1. The cleanliness and finish of the contact surface have a great impact on the working condition of the contact. When the surface of the contact is rough or there is excess material on the contact, it is easy to cause arcing and reduce the life of the contact. Therefore, the parts cleaning process should be improved to eliminate excess materials; Increasing the process of screening excess materials, ...

RKC Thermostat – How to Maintain the Instrument? RKC Thermostat – How to Maintain the Instrument?

The normal operation of the instrument is inseparable from the on-site maintenance relationship, especially some important process links, once there is a leak, it will greatly affect the quality of the product, resulting in heavy losses. First of all, it is common to install both remote and field-indicated level gauges on important tanks.

Features and technical specifications of RKG thermostats Features and technical specifications of RKG thermostats

peculiarity 1. Thermocouple, RTD, analog and other signals are freely input, and the range can be set freely. 2. The software adjusts the full degree, the cold end measures the temperature separately, the amplifier is self-stabilizing, and the display accuracy is better than 0.5%FS. 3. Fuzzy theory combined with traditional PID method, fast control ...

RHK thermostats – an introduction to the classification of displays RHK thermostats – an introduction to the classification of displays

(1) Categorize by display color 1. Monochrome display There are two types of displays: multi-grayscale monochrome display and VGA multi-frequency monochrome display. These displays are small, lightweight, clear and inexpensive, making them suitable for highly mobile workplaces. 2. Color ...

RRKC thermostat - five common faults and solutions of smart thermostats RRKC thermostat - five common faults and solutions of smart thermostats

After heating for a while, the temperature does not change. Displays the ambient temperature of the site at all times (e.g. room temperature 25°C) In case of such a fault, first check whether the SV value setting value is set, whether the OUT indicator of the meter is lit, and whether the No. 3 and No. 4 terminals of the meter are 12VDC output with the "multimeter". ...

Introduction and wiring method of Japan physical and chemical RKC thermostat Introduction and wiring method of Japan physical and chemical RKC thermostat

  The core control algorithm of the temperature regulator is PID control, P (Proportional) ratio + I (Integral) point + D (Differential) differential control. In addition to the traditional PID control algorithm, RKC also has ON-OFF control, custom parameter control, adaptive parameter control and other algorithms, ...

RLC thermostats – the classification of thermostats and their detailed introduction RLC thermostats – the classification of thermostats and their detailed introduction

1. Sudden jump thermostat The type of various sudden thermostats is collectively called KSD, such as KSD301, KSD302, etc., the thermostat is a new type of bimetal thermostat, mainly as a variety of electric heating products with overheat protection, generally connected with the thermal fuse in series, sudden temperature ...

RRC Thermostat – Instructions for use of smart thermostats RRC Thermostat – Instructions for use of smart thermostats

1. Turn on the power of the smart thermostat, and the current temperature is displayed on the display. Because the sensor is not in contact with other devices, but is exposed directly to the air, this is the current temperature: 31 degrees Celsius, which is not too hot. 2. At the bottom right of the display is the "Startup Temperature" setting.

RKC thermostat REX-C400 model settings and parameter instructions RKC thermostat REX-C400 model settings and parameter instructions

  Japan RIKA RKCREX-C400 temperature controller product introduction. REX-C400 Digital Temperature Control Controller, RKCPID Temperature Controller, Temperature Controller, (SSR Output) + Type K Thermocouple + *Large 40ASSR Relay. 1. Dual display set temperature and working ...

Wiring method of the RKG thermostat Wiring method of the RKG thermostat

Take CD901 as an example, L(1) pin to 220 volt live wire, N(2) pin 220 volt neutral wire, 3,4 pins for *** output, 5,6 pins for the second output, 7, 8, 9 pins are alarm output, The rear three pins are connected to thermocouples or PT100 and so on.

Wiring method of the RKG thermostat Wiring method of the RKG thermostat

Take CD901 as an example, L(1) pin to 220 volt live wire, N(2) pin 220 volt neutral wire, 3,4 pins for the first output, 5,6 pins for the second output, 7, 8, 9 pins are alarm output, Finally, the three pins are connected to thermocouples or PT100 ...

RLC Thermostat - Fault and Troubleshooting of Vapor Pressure Temperature Controller RLC Thermostat - Fault and Troubleshooting of Vapor Pressure Temperature Controller

Faulting and troubleshooting of vapor pressure temperature controllers (1) Common faults and common faults of the vapor pressure type temperature controller include contact burning or adhesion, failure of the mechanical transmission mechanism and leakage of temperature sensor in the temperature sensing tube. Its detection method is: put the thermostat knob in a parking position, and use ...

Specifications and models of RKC thermostats Specifications and models of RKC thermostats

1. RH400 size: 48*96, depth 60, about 250g 1. Thermocouples: K, J, R, S, B, E, N, T, W5RE/W6RE, PL‖, U, L 2. Temperature measurement heat resistance input: PT100, JPT100 3. Tributary voltage: DC0 - DC5V, DC1 - DC5V ...

Common faults and failure analysis of RTC thermostats Common faults and failure analysis of RTC thermostats

1. The power indication is normal, but the temperature controller has no screen display. Most of this fault is caused by the heating of the voltage regulator element (7805 or 7812) on the thermostat during long-term use, which leads to the breakpoint of the solder joint, and sometimes it is caused by the phenomenon of virtual soldering at the factory, and the main re-soldering can be done. 2. Temperature controller ...

RKC Temperature Control Meter - How to set the temperature control meter RKC Temperature Control Meter - How to set the temperature control meter

1. Turn on the power supply of the smart thermostat, and the temperature displayed on the screen is the temperature at that time. Because the sensor is not in contact with other devices, but is directly exposed to the air clock, this is the current temperature: 31 degrees Celsius, which is not too hot. 2. At the bottom right of the display screen is the "starting temperature" setting ...

RKC Thermostat – What are the common faults of thermostats? RKC Thermostat – What are the common faults of thermostats?

1. There is no manifestation when the power is on. For this kind of problem, first confirm whether the power supply is there and whether the power supply matches the power supply required by the thermostat, and then check whether the wiring is strong. The problem is still there, then it is the problem of the thermostat itself. 2. There is a manifestation, and the manipulation makes mistakes. The first thing to look at this kind of problem is to look at the control ...

RK Thermostat - The working principle and device precautions of liquid expansion thermostat RK Thermostat - The working principle and device precautions of liquid expansion thermostat

How liquid expansion thermostats work Liquid expansion thermostat is a physical phenomenon (volume change) that causes the material (generally liquid) in the temperature sensing part of the thermostat to undergo corresponding thermal expansion and cold contraction when the temperature of the controlled object changes, and the diaphragm box connected with the temperature sensing part expands or ...

RLC thermostats – a common failure of mechanical thermostats RLC thermostats – a common failure of mechanical thermostats

1. The terminal post of the thermostat is stuck and falls off Cause the compressor not to start, the thermostat dynamic and static contacts can not be disconnected, so that the compressor does not run, the thermostat contacts can not be disconnected, so that the motor of the refrigerator compressor does not stop, in addition to the balance elastic force is too weak, it can also be ...

RKC thermostat - introduction of the three output modes of the thermostat RKC thermostat - introduction of the three output modes of the thermostat

The first output method is relay output, which is output for temperature control through the switching signal of the relay on/off, which is used to directly control the load less than 5A, or directly control the contactor and the intermediate relay, and control the high-power load externally through the contactor. The second ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top