RKC thermostat – the correct way to adjust the thermostat

Create Date: 2024-8-30 12:03:23|Source: RKC

1. Set temperature: Press the SET button to set or view the temperature set point. Press the SET button at the beginning of the digital tube character flashing, indicating that the appearance has entered the setting state, press the △ key to increase the set value, press the ▽ key to decrease the set value, press and hold the △ key or ▽ key The data will change rapidly, press the SET key again and the appearance returns to the normal operating condition and the temperature is set.

2. Return control (XMT201-C): Press the SET button for 3 seconds to enter the inner layer parameter setting status. The first presented and flashing parameter is C00, that is, the return difference control parameter should be carefully adjusted, the appearance of the control heating output value to the set value, when the temperature falls to the set value to reduce the difference value, and then start heating, the output (relay) is not active in the return scale, so that the relay action number can be reduced to extend the life of the relay. For example, if the setting value is 80.0°C and the return difference is 0.5, the relay is released when the surface control is heated to 80.0°C, and the relay is engaged when the temperature drops to 80.0°C-0.5°C=79.5°C. The larger the return difference, the fewer the relay actions, and the excessive return difference will reduce the control accuracy. After adjusting the differential parameters, press the SET button for 3 seconds to return to the normal operating condition.

3. Early Setting (XMT201-E): Press the SET button for 3 seconds to enter the inner layer parameter setting. The first parameter that is presented and flashed is E00, that is, the early amount of heating abort, the early amount parameter should be carefully adjusted, in order to reduce the temperature overshoot, the heating output will be cut off early when the surface is manipulated. When the temperature drops below the early amount, the heat is started, and the output (relay) is not operated within the set value and the early amount scale, so that the number of relay actions can be reduced to extend the life of the relay. For example, if the setting value is 50.0°C and the early amount is 0.5, the relay is released when the surface control is heated to 49.5.0°C, and the relay is engaged again when the temperature drops to 50.0°C-0.5°C=49.5°C. The larger the early amount, the fewer the relay actions, and the excessive early amount will reduce the control accuracy. After adjusting the early amount parameters, press the SET button for 3 seconds to return to the normal operation status

4. Time share setting (XMT201-P): Press the SET button for 3 seconds to enter the inner layer parameter setting status. E: is the share band offset, and the E parameter allows the practice control point to be translated. Even if the center of the moment share shifts, the E-value can be positive or negative depending on the heating system. P: is the share band, that is, the share manipulation value, in order to facilitate understanding together and in order to make the share with more room for expression, the share band of this table is a unilateral share band, that is, the practical share band is 2 times the P value. Focusing on the practice control point, from bottom to top, the output heating share is evenly distributed from 0% to 100% within the scale of P value. T: For the heating output cycle cycle, that is, the relay operation cycle cycle, the T value is small and the control effect is good, but the T value is too small The relay will reduce the life due to frequent operation. Generally, the T value is taken for 20-60 seconds. For example, if P is set to 4.0 (the actual band is 8.0), the temperature is set to 60.0 degrees, and E is set to 2.0, then the practice control point is 58.0 degrees, and when the temperature reaches 54.0 degrees, the appearance will enter the share band control state.

5. Intelligent control parameter setting (XMT201-D): Press the SET button for 3 seconds to enter the inner parameter setting status on the outer surface. E: This parameter is the early amount of heating stop when P = 0, when P is not equal to 0, it looks like an intelligent PID operation method, and when P is not equal to 0, the E parameter is meaningless. P: is the share band, that is, the share control value, the P-value is distributed on both sides of the set point with the set value as the center of the outer table, and the PID method is used in the inner and outer tables of the P value scale. T: For the heating output cycle cycle, that is, the relay operation cycle cycle, the T value is small and the control effect is good, but the T value is too small The relay will reduce the life due to frequent operation. Generally, the T value is taken for 20-60 seconds. To simplify the operation, the integration time (I) and differentiation time (D) of the appearance are planned as hidden parameters, and their default values are: I=180, D=45

6. Correction of errors: The displayed values can be corrected when acknowledging that the values displayed on the surface are not correct measurements. Press the SET button for 3 seconds to enter the inner menu on the surface, the first parameter presented and flashed is E00, that is, the early amount, and then press the SET button again to present and flash the parameter that is the error correction parameter, and this parameter can be corrected with the △ or ▽ key. The scale of the error correction is -9.9°C to +9.9°C, and after the correction is completed, press the SET button to exit. The correction value of the appearance is 0.0 when leaving the factory, and it is necessary to avoid correcting the correct appearance to incorrect when using.
RKC thermostat – the correct way to adjust the thermostat

More on that
RKC converters – what are the functions of converters? RKC converters – what are the functions of converters?

1. Power conversion: convert the voltage (rated 100V) and current (rated 5A or 1A) of the transformer into voltage (several volts) to meet the requirements of weak current components. 2. Isolation: current, secondary side security, and work grounding are used to ensure the safety of people and equipment, while weak current ...

RKC thermostat REX-C400 model settings and parameter instructions RKC thermostat REX-C400 model settings and parameter instructions

Japan RIKA RKC REX-C400 temperature controller product introduction REX-C400 Digital Thermostat RKC PID Temperature Controller Thermostat (SSR Output) + Type K Thermocouple + *Large 40A SSR Relay 1. Dual display set temperature and process temperature 2. General Digital Programmable Temperature ...

Wiring method of the RKG thermostat Wiring method of the RKG thermostat

Take CD901 as an example, L(1) pin to 220 volt live wire, N(2) pin 220 volt neutral wire, 3,4 pins for the first output, 5,6 pins for the second output, 7, 8, 9 pins are alarm output, Finally, the three pins are connected to thermocouples or PT100 ...

Parameter setting operation of RLC temperature control table CH402 Parameter setting operation of RLC temperature control table CH402

Model: CH402FS01-8*HN (for PECVD temperature control) 1) Single press SET: SV can be set (set temperature manually) 2) Press and hold the SET button for 2 seconds, ALI=1000 (absolute alarm temperature setting) and then press the SET button, ATU=1 (self-defining, self-interpreting a set of PID parameters) to exit ...

RRKC thermostats – the commissioning steps of mechanical thermostats RRKC thermostats – the commissioning steps of mechanical thermostats

1. Confirm the angle sample first. See where the angle of the sample is today. 2. Pick up the thermostat, first confirm whether the switch of the thermostat is tight, stuck, whether the white dot falls off, whether there is sound when the thermostat contacts are in contact, and if there is no sound, there should be two possibilities! ...

RHK thermostat - 5 common problems and solutions for stand-alone thermostats RHK thermostat - 5 common problems and solutions for stand-alone thermostats

Fault 1: The thermostat does not turn on (does not light up) Analyze the causes 1. Wrong wiring 2. The voltage of the input terminal is not enough or the input terminal is damaged by empty opening and leakage 3. Whether the cable between the panel and the power board is broken or plugged incorrectly 4. Load short circuit or open circuit, probe ...

RKC thermostat - how to keep the line when installing the thermostat? RKC thermostat - how to keep the line when installing the thermostat?

First, the selection of the orientation of the thermostat device 1. Easy to operate locally; 2. It can include the average temperature of the local area; 3. Localities with more human activities; 4. It can avoid cold and heat sources; That is to say, the orientation of the device should be far away from radiators, away from doors and windows...

What should I pay attention to when wiring the RKG thermostat? What should I pay attention to when wiring the RKG thermostat?

1. For thermocouple input, the corresponding compensation wire should be used. 2. For RTD input, 3 wires with low resistance and no difference should be used 3. The input signal line should be far away from the power line of the instrument. Power supply and load lines to avoid noise interference 4. The instrument power cord is usually ...

RLC thermostat – the wiring method of the thermostat RLC thermostat – the wiring method of the thermostat

1. Prepare the thermostat, wires, and thermal resistance, and print out the wiring diagram of the thermostat 2. Use wire strippers to strip off the wire skin, use crimping pliers, and press the wire end to the cold-pressed terminal. 3. Connect the 220V power supply to the inlet terminal of the thermostat, and connect the thermal resistance to the thermostat ...

Where you need to pay attention to the wiring of the RRKC thermostat Where you need to pay attention to the wiring of the RRKC thermostat

1. For thermocouple input, the corresponding compensation wire should be used. 2. RTD input, 3 wires with low resistance and no difference should be used. 3. The input signal line should be far away from the power line of the instrument. Power supply and load lines to avoid noise interference. 4. Instrument power cord ...

RLC Thermostat – How to use a smart temperature controller RLC Thermostat – How to use a smart temperature controller

1. Set temperature: press and hold the SET key, at this time the tube character begins to flash, proving that the instrument has entered the set state, increase the up button, decrease the down button, and press and hold the up and down buttons to quickly change, when the desired temperature is reached, then press the SET button The instrument is set. 2. Return control: press SET ...

RKC Level Gauges – Precautions for Level Gauges RKC Level Gauges – Precautions for Level Gauges

The correct selection of the level gauge can ensure the better use of the level gauge. What kind of level gauge should be selected according to the physical and chemical properties of the fluid medium to be measured? What is the diameter of the level gauge, the flow range, the lining material, the electrode material, and the output current? can adapt to the ...

How to set the parameters of the RKC fb900 thermostat How to set the parameters of the RKC fb900 thermostat

Model definition FB90②③*④4⑤⑥⑦⑧⑨-0( CODE 8N-4*4NN5/A1-F801/Y control "(1)(2)" indicates Output 1 and Output 2 classes M: Relay output V: Voltage pulse output 5: 0-10V 8: 4-20mAN: No output “ ...

What should I pay attention to when setting up my RKC thermostat? What should I pay attention to when setting up my RKC thermostat?

Wiring Warning: If the instrument fails or an error occurs, which can cause a system failure, an external protection circuit is installed to prevent such accidents: In order to prevent damage or failure of the instrument, choose an appropriate fuse to protect the power cord and input and output lines from strong power shocks. Power supply ...

RLC thermostats – the classification of thermostats and their detailed introduction RLC thermostats – the classification of thermostats and their detailed introduction

1. Sudden jump thermostat The type of various sudden thermostats is collectively called KSD, such as KSD301, KSD302, etc., the thermostat is a new type of bimetal thermostat, mainly as a variety of electric heating products with overheat protection, generally connected with the thermal fuse in series, sudden temperature ...

RKC thermostat - what should be paid attention to when maintaining the thermostat? RKC thermostat - what should be paid attention to when maintaining the thermostat?

1. Do not wipe with acidic, alkaline and other corrosive liquids and water-containing rags when cleaning, so as not to damage the temperature controller and affect its normal use. 2. Do not decorate and cover the temperature controller. The thermostat has a built-in temperature sensor to sense the outside temperature. Therefore, Wen ...

How to set the parameters of the RKC rs400 thermostat? How to set the parameters of the RKC rs400 thermostat?

1. Set temperature: Press the SET button to set or check the temperature set point. Press the SET key digital tube character start flashing, indicating that the appearance has entered the setting state, press the △ key to increase the set value, press the ▽ key to decrease the set value, press and hold the △ key or ▽ key data will change rapidly, press the SET key again ...

What should be paid attention to when installing RRKC thermostats - pop-up thermostats What should be paid attention to when installing RRKC thermostats - pop-up thermostats

1. The use environment of the sudden jump thermostat should avoid stains and moisture, otherwise it will affect the electrical performance of the product, and the thermostat must be used in a working environment with a relative humidity of ≤ 90% and no contact with corrosive and flammable mediums. For use in wet environments or submerged liquids, the thermostat ...

RKC Level Gauges - Advantages and Disadvantages of Several Common Level Gauges Introduction RKC Level Gauges - Advantages and Disadvantages of Several Common Level Gauges Introduction

1. Float level gauge is an instrument that relies on the principle of buoyancy to measure the liquid level. Usually by means of a float in conjunction with a scale, the observer can visually read the height of the liquid level. Advantages: fast and intuitive reading; Low price; Easy to install. Shortcoming:...

RRKC thermostat wiring installation and some precautions RRKC thermostat wiring installation and some precautions

The rkc controller was developed by Japan and is mainly used in plastics and stoves. Of course, it is also widely used in China's industry, there are many people who do not know much about the rkc controller, and some even feel unfamiliar.

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top