RKC thermostat REX-C400 model settings and parameter instructions

Create Date: 2024-8-30 12:03:23|Source: RKC

Japan RIKA RKCREX-C400 temperature controller product introduction.

REX-C400 Digital Temperature Control Controller, RKCPID Temperature Controller, Temperature Controller, (SSR Output) + Type K Thermocouple + *Large 40ASSR Relay.

                RKC thermostat REX-C400 model settings and parameter instructions

1. Dual display of set temperature and process temperature.

2. Universal digital programmable temperature controller, support a variety of thermocouple sensors. It can be powered by 85-265VAC, Comsumption 5VA. DIN1/16。

3. Display the temperature in degrees Celsius.

4.Four digital LED display up to 9999

5.P is powered by DC or AC power supply.

6. Used for temperature control of kiln, furnace, oven and incubator.

7. Used for heating control and cooling control.

8. Used in all walks of life, control and monitor process temperature.

Technical parameters of Japan physical and chemical rkcREX-C400 temperature regulator:

REX-C400 (SSR) thermostat.

Display: Celsius temperature dual display (C)

Range: -0-400C (for factory type k thermocouples only)

Output: SSR.

PID cooling/heating control.

1RELAY ALARM: NORMALLY OPEN, 250V/3AAC OR 30V/3ADC CAPACITY.

7 different dual output combinations including High/Low/High/Low/Low/Interval/Over Interval/Damage Alarm.

Accuracy: 0.5%

Input: Thermal resistance T100, Cu50.

Thermocouples: j, s, k, e, Wre3 - Wre25.

Size IN: 1/8 (48mmx96mmx110mm)

Weight: about 300 grams.

Type K thermocouple probe cable.

  1.Length:1M。

2. Sensor diameter: 5 mm.

3. Temperature range: 0-400.

4. Internal insulation: fiberglass.

5. External shielding: insulation shielding.

* Large 40ASSR.

1. Output current: 40A.

2. Input voltage: DC 3-32V.

3. Output voltage: 24-380VAC.

4. Output voltage range: standard type.

The course includes:

SET1: REXC400SSR settings.

1XPID thermostat.

One XK type probe sensor.

  1XMax.40ASSR。

SET1: REXC400SSR list.

1XPID thermostat.

Japan physical and chemical rkcREX-C400 temperature controller wiring control method.

Beijing Zhongping Technology Co., Ltd. provides Japan physical and chemical rkcREX-C400 transformer temperature regulator wiring method product collection, wiring diagram principle introduction, Japan physical and chemical rkcREX-C400 transformer temperature regulator wiring method photos.

Japan physical and chemical rkc temperature regulator specifications and models sales:

Digital Multipoint Controllers (Temperature Controllers)

  MA900。

  MA901。

Digital Display Controllers (Process/Temperature Controllers)

(1) High-precision, high-performance product series.

  FZ110。

  FZ400。

  FZ900。

  HA900。

  HA400。

  FB900。

  FB400。

  FB100。

  REX-F9000。

  REX-F400。

  REX-F700。

  REX-F900。

  REX-D100。

  REX-D400。

  REX-D900。

Digital Display Controllers (Temperature Controllers)

(2) Small, space-saving, standard product series.

  RS100,RS400。

  RD100、RD400、RD500、RD700、RD900RH100、RH400、RH900。

  RB100,RB400,RB500,RB700,RB900。

  SA200,SA100,

  CD101、CD401、CD501、CD701、CD901。

  CH102,CH402,CH902。

  CB100,CB400,CB500,CB700,CB900。

  CB103,CB403,CB903。

  REX-C100,REX-C410,REX-C700,REX-C400,REX-C900。

More on that
Introduction to the functions of the RKC temperature control meter Introduction to the functions of the RKC temperature control meter

(1) RH400 size: 48*96, depth 60, about 250g Details: ●A variety of input types are available: 1) Thermocouples: K, J, R, S, B, E, N, T, W5RE/W6RE, PL‖, U, L 2) Temperature measurement RTD input: PT100, JPT100...

What are the characteristics of RLC thermostats – mechanical thermostats? What are the characteristics of RLC thermostats – mechanical thermostats?

1. Used to control fan coil unit, electric valve, damper and other equipment; 2. The switch adopts toggle type, which feels comfortable and has a long life; 3. Set the temperature by twisting (the temperature range can be limited); 4. The thermostat can be installed directly on the wall or on the standard junction box; ...

RKC Thermostat – Teach you how to choose a thermostat RKC Thermostat – Teach you how to choose a thermostat

(1) Size selection When replacing the thermostat, choose according to the original size; The newly added thermostat should take into account the overall coordination of the cabinet installed, too large to fit, too small to see the display, the same function of the thermostat, the price of large volume will be more expensive, small size may function expansion...

Introduction and wiring method of Japan physical and chemical RKC thermostat Introduction and wiring method of Japan physical and chemical RKC thermostat

  The core control algorithm of the temperature regulator is PID control, P (Proportional) ratio + I (Integral) point + D (Differential) differential control. In addition to the traditional PID control algorithm, RKC also has ON-OFF control, custom parameter control, adaptive parameter control and other algorithms, ...

RK Level Gauge - Four common types of faults and solutions for float level gauges RK Level Gauge - Four common types of faults and solutions for float level gauges

1. The indicated value is large (or out of range). According to the investigation of our staff, this kind of problem often appears in the atmospheric pressure workshop. When we find that the counterweight of the float in the float level gauge is at a low point, the liquid level must be very high at this time, and the glass plate is inconsistent with the indication of the instrument.

What are the rich functions of RRKC thermostats – wall mounted thermostats? What are the rich functions of RRKC thermostats – wall mounted thermostats?

The wall-mounted thermostat is an ultra-thin intelligent thermostat that integrates measurement, display, control, alarm, recording and other functions, which can realize accurate measurement and control of temperature, pressure, flow and other parameters. Available in three sizes of 5 inches, 7 inches and 9 inches, a total of 12 models are available ...

RLC thermostat – the wiring method of the thermostat RLC thermostat – the wiring method of the thermostat

Many household appliances and large-scale equipment products will be installed in the use of thermostats, thermostats will be combined with the change of ambient temperature in the switch when working physical deformation, which will produce some special effects, resulting in conduction or disconnection action, in order to achieve automatic ...

RKC Level Gauge – Installation of a pontoon level gauge RKC Level Gauge – Installation of a pontoon level gauge

When transporting and unpacking, it is necessary to avoid excessive shock and vibration; The installation should be firm and reliable, and the pontoon should be installed vertically to prevent the pontoon from colliding with the interior wall of the pontoon; When the pontoon is hooked, it should not swing or pull and compress sharply, so as not to damage the sensor and reduce the accuracy of the instrument; ...

RLC Thermostat – Instructions for installation and use of pop-up thermostats RLC Thermostat – Instructions for installation and use of pop-up thermostats

1. Grounding method: It is connected to the grounding metal parts of the equipment through the metal cover of the thermostat. 2. The thermostat should work in the general indoor environment where the relative humidity of the air is not more than 90%, and there are no corrosive gases, flammable gases and conductive dust. 3. The thermostat adopts contact ...

rkc thermostat – five advantages of thermostat over PLC rkc thermostat – five advantages of thermostat over PLC

Programmable logic controllers (PLCs) and temperature controllers (thermostats) offer similar benefits in ensuring effective process control, achieving consistent quality, and minimizing user error in manufacturing. Since the 17th century, process control equipment has been used in a variety of forms.

RK Level Gauge - Typical Fault Problems and Solutions of Pontoon Level Gauges RK Level Gauge - Typical Fault Problems and Solutions of Pontoon Level Gauges

1. There is no liquid level display or lower liquid level display When the sewage is discharged, only a small amount of condensate flows out, and it is judged that the pontoon is blocked. Treatment: Dismantle the outer pontoon and find that the pontoon is almost filled with dirt and impurities. Clean, calibrate, and return to normal. 2. The liquid level display is ...

RKC Level Gauge – Some installation requirements for pontoon level gauges RKC Level Gauge – Some installation requirements for pontoon level gauges

1. The installation of the level gauge must be vertical to ensure that the inner pontoon can move up and down freely in the pipe body. 2. Install a shut-off valve between the container and the liquid level gauge to clean and overhaul the liquid level timing to cut off the material. 3. No magnets are allowed to approach around the main body of the pontoon level gauge, otherwise ...

RDC converters – a classification of power converters RDC converters – a classification of power converters

Motors are divided into two categories: DC motors and AC motors, and AC motors are divided into asynchronous motors and synchronous motors, and their respective speed regulation principles are also different. According to the speed regulation requirements of the motor, it can be divided into two categories: DC power converter and AC power converter: ...

What should I pay attention to when setting up my RKC thermostat? What should I pay attention to when setting up my RKC thermostat?

Wiring Warning: If the instrument fails or an error occurs, which can cause a system failure, an external protection circuit is installed to prevent such accidents: In order to prevent damage or failure of the instrument, choose an appropriate fuse to protect the power cord and input and output lines from strong power shocks. Power supply ...

RLC thermostat - classification and detailed explanation of floor heating thermostat RLC thermostat - classification and detailed explanation of floor heating thermostat

1. Mechanical The sensitive gas diaphragm box or thermal bimetal sheet is used as the temperature sensing element to form the temperature control switch of the mechanical contact. This kind of thermostat is more in the European and American markets, and only a few domestic manufacturers promote such products. Mechanical floor heating thermostats usually have contact currents of no more than 8A, which are suitable for ...

RHK thermostat – a rapid detection method for common air conditioner thermostats RHK thermostat – a rapid detection method for common air conditioner thermostats

1. Bellows or diaphragm air conditioner thermostat 1. Fault phenomenon: poor contact or burning, resulting in the circuit can not be connected; The frequent action of the contact arc and sticking causes the circuit to be unbreakable; The thermostat in the temperature sensing chamber leaks, causing the contact to fail to operate and lose control. ...

Wiring method of the RKG thermostat Wiring method of the RKG thermostat

Take CD901 as an example, L(1) pin to 220 volt live wire, N(2) pin 220 volt neutral wire, 3,4 pins for *** output, 5,6 pins for the second output, 7, 8, 9 pins are alarm output, The rear three pins are connected to thermocouples or PT100 and so on.

Parameter setting operation of RLC temperature control table CH402 Parameter setting operation of RLC temperature control table CH402

Model: CH402FS01-8*HN (for PECVD temperature control) 1) Single press SET: SV can be set (set temperature manually) 2) Press and hold the SET button for 2 seconds, ALI=1000 (absolute alarm temperature setting) and then press the SET button, ATU=1 (self-defining, self-interpreting a set of PID parameters) to exit ...

Introduction to the types of alarms for RKC thermostats Introduction to the types of alarms for RKC thermostats

* Alarm table {ALM1} (standard built-in) A: Upper limit deviation alarm G: Standby upper and lower limit deviation alarm attached B: Lower limit deviation alarm H: Upper limit input value alarm C: Upper and lower limit deviation alarm J: Lower limit input value alarm D: Alarm in the range K: Attached standby ...

RKG thermostat – how the temperature controller sets the parameters RKG thermostat – how the temperature controller sets the parameters

1. Lower limit deviation alarm setting: press the SET key to select and display "SLP", the green display screen displays the value of the parameter, and select the shift, increment, and decrement keys to set or modify the parameter. This parameter indicates the difference between the alarm point and the master setpoint. 2. The upper limit deviation alarm is set ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top