RRC thermostat - introduction to the working principle and classification of electronic thermostats

Create Date: 2024-8-30 12:03:23|Source: RKC

Principle of electronic thermostat:

The electronic temperature controller (resistive type) is measured by the method of resistance temperature sensing, and generally uses platinum wire, copper wire, tungsten wire and semiconductor (thermistor, etc.) as the temperature measurement resistor, which has its own advantages and disadvantages. Most of the sensors in the temperature controller of household air conditioners are thermistors. The temperature range in the air-conditioned room controlled by the temperature controller is generally 18°C--28°C.

The temperature controller commonly used in window air conditioners uses the principle of pressure to push the contacts on and off. Its structure consists of bellows, temperature sensing bag (test tube), eccentric wheel, micro switch, etc., which is composed of a sealed induction system and a system for transmitting signal power. The temperature controller control method is generally divided into two kinds: one is controlled by the temperature change of the cooled object, and the vapor pressure temperature controller is mostly used, and the other is controlled by the temperature difference change of the cooled object, and the electronic temperature controller is mostly used.

Electronic Thermostat Classification:

Resistance thermostats and thermocouple thermostats. The main components of the circuit system are: temperature controller, thermal protector, main control switch, operating capacitor, and operating capacitor of fan motor. The role of the temperature controller is simply to control the start and stop of the compressor.
RRC thermostat - introduction to the working principle and classification of electronic thermostats

More on that
RKC converters – what are the functions of converters? RKC converters – what are the functions of converters?

1. Power conversion: convert the voltage (rated 100V) and current (rated 5A or 1A) of the transformer into voltage (several volts) to meet the requirements of weak current components. 2. Isolation: current, secondary side security, and work grounding are used to ensure the safety of people and equipment, while weak current ...

RKC thermostat How to quickly understand the wiring diagram of the thermostat RKC thermostat How to quickly understand the wiring diagram of the thermostat

There are many models of temperature controllers, and the output methods are slightly different, but the wiring principle is the same. The working principle of the thermostat: the main circuit of the power supply is directly connected to the heating device through the main contact of the AC contactor.

Wiring method of the RKG thermostat Wiring method of the RKG thermostat

Take CD901 as an example, L(1) pin to 220 volt live wire, N(2) pin 220 volt neutral wire, 3,4 pins for *** output, 5,6 pins for the second output, 7, 8, 9 pins are alarm output, The rear three pins are connected to thermocouples or PT100 and so on.

rkc thermostat – five advantages of thermostat over PLC rkc thermostat – five advantages of thermostat over PLC

Programmable logic controllers (PLCs) and temperature controllers (thermostats) offer similar benefits in ensuring effective process control, achieving consistent quality, and minimizing user error in manufacturing. Since the 17th century, process control equipment has been used in a variety of forms.

RHK thermostat – a rapid detection method for common air conditioner thermostats RHK thermostat – a rapid detection method for common air conditioner thermostats

1. Bellows or diaphragm air conditioner thermostat Fault Symptom: Poor contact or burning, resulting in the circuit cannot be connected; The frequent action of the contact arc and sticking causes the circuit to be unbreakable; The leakage of the thermostat in the temperature sensing chamber causes the contact to fail to operate and lose control ...

Common faults and solutions of intelligent temperature controllers - RTC Common faults and solutions of intelligent temperature controllers - RTC

Master the common problems of several common intelligent temperature controllers, and solve them by yourself when you encounter problems, and you don't need to spend time and effort to find someone to repair, the common problems are as follows: 1. Heating for a period of time, the temperature does not change. Ambient temperature (e.g., room temperature 25°C) is displayed at all times ...

RKC Level Gauge – How the level gauge works RKC Level Gauge – How the level gauge works

Measuring principle with hydrostatic pressure: When the level transmitter is placed at a certain depth in the liquid to be measured, the pressure on the welcome surface of the sensor is formulated as: Ρ = ρ .g.H + Po where: P: The pressure on the fluid surface of the transmitter ρ: the density of the liquid to be measured g ...

RTC thermostat - how to set the parameters of the thermostat RTC thermostat - how to set the parameters of the thermostat

1. Lower limit deviation alarm setting: Press the SET key to select and display "SLP", the green display screen displays the value of the parameter, and select the shift, increment, and decrement keys to set or modify the parameter. This parameter indicates the difference between the alarm point and the master setpoint. 2. The upper limit deviation alarm is set ...

RKC Thermostat – How to Maintain the Instrument? RKC Thermostat – How to Maintain the Instrument?

The normal operation of the instrument is inseparable from the on-site maintenance relationship, especially some important process links, once there is a leak, it will greatly affect the quality of the product, resulting in heavy losses. First of all, it is common to install both remote and field-indicated level gauges on important tanks.

RKC Level Gauge – Installation of a pontoon level gauge RKC Level Gauge – Installation of a pontoon level gauge

When transporting and unpacking, it is necessary to avoid excessive shock and vibration; The installation should be firm and reliable, and the pontoon should be installed vertically to prevent the pontoon from colliding with the interior wall of the pontoon; When the pontoon is hooked, it should not swing or pull and compress sharply, so as not to damage the sensor and reduce the accuracy of the instrument; ...

Specifications and models of RKC thermostats Specifications and models of RKC thermostats

1. RH400 size: 48*96, depth 60, about 250g 1. Thermocouples: K, J, R, S, B, E, N, T, W5RE/W6RE, PL‖, U, L 2. Temperature measurement heat resistance input: PT100, JPT100 3. Tributary voltage: DC0 - DC5V, DC1 - DC5V ...

Causes and treatment methods of inverter overvoltage Causes and treatment methods of inverter overvoltage

 1. According to the theory of cutting off the overvoltage, when the transformer is cut off, the current in the transformer inductance cannot be abruptly changed, and the stored magnetic field energy forms a vibration between the excitation inductance of the transformer and the ground capacitor, and the overvoltage occurs. 2. Transformer ...

What are the rich functions of RRKC thermostats – wall mounted thermostats? What are the rich functions of RRKC thermostats – wall mounted thermostats?

The wall-mounted thermostat is an ultra-thin intelligent thermostat that integrates measurement, display, control, alarm, recording and other functions, which can realize accurate measurement and control of temperature, pressure, flow and other parameters. Available in three sizes of 5 inches, 7 inches and 9 inches, a total of 12 models are available ...

RLC thermostat - a classification introduction of floor heating thermostats RLC thermostat - a classification introduction of floor heating thermostats

Floor heating thermostats can be divided into digital thermostats and analog thermostats according to different input and output forms. Digital thermostats generally have liquid crystal display or digital tube display panels, and set and control the temperature through buttons, while analog thermostats generally use knobs or slider band wave wheels to set ...

RHK product model introduction RHK product model introduction

RHK Recommended Product Models: Single-phase power conditioner THV-10(20A, 30A, 45A, 60A, 80A, 100A)   Ethernet communication converter COM-ME series   USB communication converter COM-KG   Digital Display Controller (Process/Temperature)

RLC thermostat - classification and detailed explanation of floor heating thermostat RLC thermostat - classification and detailed explanation of floor heating thermostat

1. Mechanical The sensitive gas diaphragm box or thermal bimetal sheet is used as the temperature sensing element to form the temperature control switch of the mechanical contact. This kind of thermostat is more in the European and American markets, and only a few domestic manufacturers promote such products. Mechanical floor heating thermostats usually have contact currents of no more than 8A, which are suitable for ...

How to set the parameters of the RKG thermostat - intelligent digital display controller? How to set the parameters of the RKG thermostat - intelligent digital display controller?

1. First of all, the digital display should be installed on the cabinet, so the overall coordination should be considered, too large may not fit, too small to see the display numbers. 2. In addition, the large size of the instrument is generally more expandable, the same function price may be expensive, the small size of the instrument may be ...

Classification of thermostats and their brief introduction Classification of thermostats and their brief introduction

Pop-up thermostat Bimetal Disc Jump Thermostat is a kind of bimetal sheet after constant temperature as a heat-sensitive reaction component, when the temperature of the main part of the product rises, the heat generated is transferred to the bimetal disc, and when the operating temperature is set, it acts quickly, and acts through the mechanism to act as a contact ...

How to set the parameters of RKC thermostat RH900 How to set the parameters of RKC thermostat RH900

1. Lower limit deviation alarm setting: press the SET key to select and display "SLP", the green display screen displays the value of the parameter, and select the shift, increment, and decrement keys to set or modify the parameter. This parameter indicates the difference between the alarm point and the master setpoint. 2. The upper limit deviation alarm is set ...

RLC thermostat - common faults and treatment methods of dry-type transformer thermostats RLC thermostat - common faults and treatment methods of dry-type transformer thermostats

1. There is no display of dry-type transformer thermostat Cause of failure: (1) The power supply of the thermostat is not connected; (2) The fuse is blown out. Solution: (1) Turn on the power supply; (2) Replace the fuse. 2. The dry-type transformer thermostat shows that one or three phases are flashing and displays "-OP-" ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top