RLC thermostat – the wiring method of the thermostat

Create Date: 2024-8-30 12:03:23|Source: RKC

1. Prepare the thermostat, wires, and thermal resistance, and print out the wiring diagram of the thermostat

2. Use wire strippers to strip off the wire skin, use crimping pliers, and press the wire end to the cold-pressed terminal.

3. Connect the 220V power supply to the inlet terminal of the thermostat, and connect the thermal resistance to the analog input terminal of the thermostat.

4. Connect the heating resistor to the output terminal of the thermostat

5. Power on, observe the temperature detected by the thermostat, and set the temperature you want, and wait for the thermostat to adjust automatically.
RLC thermostat – the wiring method of the thermostat

More on that
RKC Temperature Control Meter - How to set the temperature control meter RKC Temperature Control Meter - How to set the temperature control meter

1. Turn on the power supply of the smart thermostat, and the temperature displayed on the screen is the temperature at that time. Because the sensor is not in contact with other devices, but is directly exposed to the air clock, this is the current temperature: 31 degrees Celsius, which is not too hot. 2. At the bottom right of the display screen is the "starting temperature" setting ...

RK thermostat - the problem that should be paid attention to in the installation of floor heating thermostat RK thermostat - the problem that should be paid attention to in the installation of floor heating thermostat

1. Wall installation, the height is about 1.2 meters, generally on the same horizontal line as the electric lighting switch of the home. 2. Installed on a wall where the surrounding air flows freely, and is not affected by other heat sources (e.g. sunlight), air flow from doors and windows, or external wall temperature, etc. 3. Advance ...

Specifications and models of RKC thermostats Specifications and models of RKC thermostats

CH102 (48×48×100mm) CH402 (48×96×100mm) CH902 (96×96×100mm) 1. RH400 size: 48*96, depth 60, about 250g 1. Thermocouples: K, J, R, S, B, E, N, T, W5RE/W6RE, PL‖, U, L ...

RHK thermostat - the use of electronic thermostat and its classification introduction RHK thermostat - the use of electronic thermostat and its classification introduction

First, the use of electronic temperature controller The electronic temperature controller (resistive type) is measured by the method of resistance temperature sensing, and generally uses platinum wire, copper wire, tungsten wire and semiconductor (thermistor, etc.) as the temperature measurement resistor, and these resistors have their own advantages and points. Home Air Conditioner ...

Precautions for the use of RKC thermostats Precautions for the use of RKC thermostats

fold When the RKC thermostat comes out, it is a single-loop regulator, that is, it only has a heating function, which is called the basic meter, which is generally sent to the agent, and the agent will expand the multi-channel adjustment and alarm output control function, which is called "changing the meter" in the industry, so as to ensure that there is very little hardware cost.

RKC Level Gauge – The correct way to use the float level gauge RKC Level Gauge – The correct way to use the float level gauge

(1) Before use, first check whether the level gauge is within the verification cycle, otherwise, it should be calibrated, and replaced in time if it is unqualified. (2) The sensor should be installed horizontally, and the length of the lower entry should meet the technical requirements. (3) The connection between the sensor and the explosion-proof junction box should be tightened and tightened.

RRC Thermostat – Instructions for use of smart thermostats RRC Thermostat – Instructions for use of smart thermostats

1. Turn on the power of the smart thermostat, and the current temperature is displayed on the display. Because the sensor is not in contact with other devices, but is exposed directly to the air, this is the current temperature: 31 degrees Celsius, which is not too hot. 2. At the bottom right of the display is the "Startup Temperature" setting.

What should be paid attention to when installing RRKC thermostats - pop-up thermostats What should be paid attention to when installing RRKC thermostats - pop-up thermostats

1. The use environment of the sudden jump thermostat should avoid stains and moisture, otherwise it will affect the electrical performance of the product, and the thermostat must be used in a working environment with a relative humidity of ≤ 90% and no contact with corrosive and flammable mediums. For use in wet environments or submerged liquids, the thermostat ...

Wiring method of the RKG thermostat Wiring method of the RKG thermostat

Take CD901 as an example, L(1) pin to 220 volt live wire, N(2) pin 220 volt neutral wire, 3,4 pins for the first output, 5,6 pins for the second output, 7, 8, 9 pins are alarm output, Finally, the three pins are connected to thermocouples or PT100 ...

rkc thermostat – five advantages of thermostat over PLC rkc thermostat – five advantages of thermostat over PLC

Programmable logic controllers (PLCs) and temperature controllers (thermostats) offer similar benefits in ensuring effective process control, achieving consistent quality, and minimizing user error in manufacturing. Since the 17th century, process control equipment has been used in a variety of forms.

RKC thermostat - how to keep the line when installing the thermostat? RKC thermostat - how to keep the line when installing the thermostat?

First, the selection of the orientation of the thermostat device 1. Easy to operate locally; 2. It can include the average temperature of the local area; 3. Localities with more human activities; 4. It can avoid cold and heat sources; That is to say, the orientation of the device should be far away from radiators, away from doors and windows...

Specifications and models of RLC thermostats Specifications and models of RLC thermostats

CH102 (48×48×100mm) CH402 (48×96×100mm) CH902 (96×96×100mm) 1. RH400 size: 48*96, depth 60, about 250g 1. Thermocouples: K, J, R, S, B, E, N, T, W5RE/W6RE, PL‖, U, L ...

RKC thermostat REX-C400 model settings and parameter instructions RKC thermostat REX-C400 model settings and parameter instructions

Japan RIKA RKC REX-C400 temperature controller product introduction REX-C400 Digital Thermostat RKC PID Temperature Controller Thermostat (SSR Output) + Type K Thermocouple + *Large 40A SSR Relay 1. Dual display set temperature and process temperature 2. General Digital Programmable Temperature ...

RRKC thermostat wiring installation and some precautions RRKC thermostat wiring installation and some precautions

The rkc controller was developed by Japan and is mainly used in plastics and stoves. Of course, it is also widely used in China's industry, there are many people who do not know much about the rkc controller, and some even feel unfamiliar.

Wiring method and control method of RKC thermostat Wiring method and control method of RKC thermostat

1. Wiring method Take CD901 as an example, L(1) pin to 220 volt live wire, N(2) pin 220 volt neutral wire, 3,4 pins for the first output, 5,6 pins for the second output, 7, 8, 9 pins are alarm output, The last three legs are connected to ...

RKC thermostat wiring needs to pay attention to RKC thermostat wiring needs to pay attention to

Wiring Notes: 1. For thermocouple input, the corresponding compensation wire should be used. 2. RTD input, 3 wires with low resistance and no difference should be used. 3. The input signal line should be far away from the power line of the instrument. Power supply and load lines to avoid noise interference. ...

RKC Level Gauge – Precautions for the installation of float level gauges RKC Level Gauge – Precautions for the installation of float level gauges

1. The specific gravity of the liquid to be measured must be greater than the specific gravity of the float 2. The measured medium should not contain ferromagnetic impurities 3. The float level gauge should be installed in an unobstructed position when the float moves up and down 4. Magnets are not allowed to be close around the float level gauge, otherwise it will affect the float.

Classification of thermostats and their brief introduction Classification of thermostats and their brief introduction

Pop-up thermostat Bimetal Disc Jump Thermostat is a kind of bimetal sheet after constant temperature as a heat-sensitive reaction component, when the temperature of the main part of the product rises, the heat generated is transferred to the bimetal disc, and when the operating temperature is set, it acts quickly, and acts through the mechanism to act as a contact ...

RKC Level Gauge – the correct way to use the float level gauge RKC Level Gauge – the correct way to use the float level gauge

(1) Before use, first check whether the level gauge is within the verification cycle, otherwise, it should be calibrated, and replaced in time if it is unqualified. (2) The sensor should be installed horizontally, and the length of the lower entry should meet the technical requirements. (3) The connection between the sensor and the explosion-proof junction box should be tightened and tightened.

RRC thermostat - the principle of sudden jump thermostat, how to judge the good or bad? RRC thermostat - the principle of sudden jump thermostat, how to judge the good or bad?

1. What is the principle of the sudden jump thermostat? The sudden jump thermostat is a kind of thermostat, which is a series of automatic control elements that are physically deformed inside the switch according to the temperature change of the working environment, resulting in some special effects and on-off action. Sudden jump ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top