1. Set temperature: press and hold the SET key, at this time the tube character begins to flash, proving that the instrument has entered the set state, increase the up button, decrease the down button, and press and hold the up and down buttons to quickly change, when the desired temperature is reached, then press the SET button The instrument is set.
2. Return control: Press the SET button for 3 seconds to enter the meter setting. The first flashing parameter is C00, and the differential control parameter should be carefully adjusted, and the heating will start when the temperature drops to the set value minus the difference. The larger the return difference value, the less the relay action, after adjusting the return difference parameters, press the SET button for 3 seconds to return to the working state.
3. Advance setting: Press the SET button for 3 seconds to enter the state. The first flashing parameter is the heating stop state, the larger the advance amount, the less the relay action, if the amount is too large to reduce the control accuracy, press the SET button for 3 seconds The instrument will reach the normal state.
4. Time ratio setting: press the SET button for 3 seconds to enter the inner setting state. The T value is small and the control effect is replaced, and the normal T value is better than 20-60 seconds. E is set to 2.0 and the actual control point is 58.0 degrees.
5. Correction of error: If the display value of the instrument is very correct, the display value can be corrected. The first one appears and flashes the parameter as E00, that is, the advance amount, press it as the error correction parameter again, and press the up and down keys to modify this parameter. The error range is ±9.9°C, and you can exit by pressing the SET button after the correction is confirmed. The normal meter is corrected to 0.0 at the factory, and it is necessary to prevent the correct meter from being corrected to incorrect before use.
|
More on that
|
RLC Thermostat - Overview and characteristics of mechanical thermostats
Mechanical thermostats are suitable for indoor temperature control in industrial, commercial and residential buildings. The mechanical thermostat uses an inflatable diaphragm box to sense the temperature and compare it with the user's set temperature to automatically control the air conditioning equipment to achieve the purpose of indoor constant temperature. For commercial, industrial and civil construction, available ...
|
|
How the thermostat works – RKC
Thermostat, according to the temperature change of the working environment, physical deformation occurs inside the switch, so as to produce some special effects, a series of automatic control elements that produce on-on or off-action actions, or different principles of electronic components at different temperatures and working states to give ...
|
|
RKC Level Gauge – How the level gauge works
Measuring principle with hydrostatic pressure:
When the level transmitter is placed at a certain depth in the liquid to be measured, the pressure on the welcome surface of the sensor is formulated as: Ρ = ρ .g.H + Po
where:
P: The pressure on the fluid surface of the transmitter
ρ: the density of the liquid to be measured
g ...
|
|
RRKC Thermostat – The working principle and main features of the pop-up thermostat
How it works
The sudden jump thermostat is a kind of bimetal disc after constant temperature as a heat-sensitive reaction component, when the temperature of the main part of the product increases or decreases, the heat generated is transferred to the bimetal disc, and when the operating temperature is set, it acts quickly, and the contact is broken through the action of the mechanism.
|
|
What are the technical parameters of the rkc thermostat - the jump thermostat?
1. Electrical parameters: (1) VDE, CQC, UL, TüVAC250V 50-60Hz 10A (resistive load) (2) ULAC125V 50Hz 15A (resistive load)
2. Operating temperature range: -50-270°C (optional), temperature accuracy: ≥ ±2°C
3. Reset and action ...
|
|
RRKC thermostats – the commissioning steps of mechanical thermostats
1. Confirm the angle sample first. See where the angle of the sample is today.
2. Pick up the thermostat, first confirm whether the switch of the thermostat is tight, stuck, whether the white dot falls off, whether there is sound when the thermostat contacts are in contact, and if there is no sound, there should be two possibilities!
...
|
|
RK thermostat - the performance characteristics of digital display thermostat are introduced
1. The special integrated instrument chip has more reliable anti-interference and stability.
2. Signal input, ordinary heat signal can be connected through menu settings.
3. You can modify the display range, transmission output range, alarm value and online report J mode.
4. Soft ...
|
|
What should be paid attention to when installing RRKC thermostats - pop-up thermostats
1. The use environment of the sudden jump thermostat should avoid stains and moisture, otherwise it will affect the electrical performance of the product, and the thermostat must be used in a working environment with a relative humidity of ≤ 90% and no contact with corrosive and flammable mediums. For use in wet environments or submerged liquids, the thermostat ...
|
|
RRC thermostat - introduction to the working principle and classification of electronic thermostats
Principle of electronic thermostat:
The electronic temperature controller (resistive type) is measured by the method of resistance temperature sensing, and generally uses platinum wire, copper wire, tungsten wire and semiconductor (thermistor, etc.) as the temperature measurement resistor, which has its own advantages and disadvantages. Household Air Conditioner Temperature Controller ...
|
|
Parameter setting operation of RLC temperature control table CH402
Model: CH402FS01-8*HN (for PECVD temperature control)
1) Single press SET: SV can be set (set temperature manually)
2) Press and hold the SET button for 2 seconds, ALI=1000 (absolute alarm temperature setting) and then press the SET button, ATU=1 (self-defining, self-interpreting a set of PID parameters) to exit ...
|
|
Difference Between Thermocouple and RTD
In temperature measurement, thermocouples and RTDs are both contact temperature measurements, and although they both measure the temperature of an object, their principles and characteristics are different.
This article first introduces thermocouples, which are widely used in temperature measurement temperature control devices.
|
|
RLC thermostat – the wiring method of the thermostat
1. Prepare the thermostat, wires, and thermal resistance, and print out the wiring diagram of the thermostat
2. Use wire strippers to strip off the wire skin, use crimping pliers, and press the wire end to the cold-pressed terminal.
3. Connect the 220V power supply to the inlet terminal of the thermostat, and connect the thermal resistance to the thermostat ...
|
|
RK thermostat - the use and adjustment of temperature control instruments
1. Set temperature: Press the SET button to set or check the temperature set point. Press the SET button at the beginning of the digital tube character flashing, indicating that the appearance has entered the setting state, press the △ key to add the set value, press the v key to decrease the setting value, press and hold the △ key or √ key The data will change rapidly, press the SET key again ...
|
|
RK Level Gauge - Typical Fault Problems and Solutions of Pontoon Level Gauges
1. There is no liquid level display or lower liquid level display
When the sewage is discharged, only a small amount of condensate flows out, and it is judged that the pontoon is blocked.
Treatment: Dismantle the outer pontoon and find that the pontoon is almost filled with dirt and impurities. Clean, calibrate, and return to normal.
2. The liquid level display is ...
|
|
What should I pay attention to when setting up my RKC thermostat?
Wiring Warning:
If the instrument fails or an error occurs, which can cause a system failure, an external protection circuit is installed to prevent such accidents:
In order to prevent damage or failure of the instrument, choose an appropriate fuse to protect the power cord and input and output lines from strong power shocks.
Power supply ...
|
|
RKC Level Gauges – An introduction to common types of level gauges
Explosion-proof float level switch
Explosion-proof float level switch, also known as explosion-proof float level controller. It is a liquid level control instrument specially designed and manufactured for use in explosive atmospheres, this product is designed based on the principle of buoyancy and the principle of lever, when the liquid level in the container changes, ...
|
|
RKC Level Gauges – How to Install Float Level Gauges Correctly
In general, the following points should be followed when installing a float level timer:
1. In order to prevent the float from sliding or hitting the sealed tube at high speed during transportation, causing the measuring belt to fall out, the instrument is fixed at the bottom of the sealed tube with a clamp before leaving the factory, and the magnet is on the top of the sealed tube.
|
|
RKC Thermostat Common faults of thermostats
The power indicator is normal, but the temperature control meter has no on-screen display. This kind of fault is mostly caused by the heating of the voltage regulator element (7805 or 7812) of the temperature controller during long-term use, resulting in a break point in the solder joint, and sometimes a virtual soldering occurs at the factory, resulting in re-soldering.
...
|
|
Initialization parameter setting of the rkc thermostat
1. Press the ISET) button for 2 seconds to enter the parameter setting mode, press ISET until "LCK" is displayed, press the [] key to move the cursor to the thousands, and press the [] button to change the number of thousands from "0" to "1" to display "1000" to unlock.
2. Press the ISET button for 3 seconds to return to SV/PV display mode
3. Press [SET]+ ...
|
|
RKC thermostat - how to set the parameters of the thermostat?
1. Lower limit deviation alarm setting: press the SET key to select and display "SLP", the green display screen displays the value of the parameter, and select the shift, increment, and decrement keys to set or modify the parameter. This parameter indicates the difference between the alarm point and the master setpoint.
2. The upper limit deviation alarm is set ...
|
|