Explain in detail the setting method of arc static during welding of Yaskawa welding robot

Create Date: 2024-8-30 12:03:23|Source: YASKAWA/Yaskawa

1. Conditions for the static characteristics of the arc of Yaskawa welding robots

In the welding production process, once the electrode material, gas medium and arc length are maintained, as long as the arc of the Yaskawa welding robot can burn stably, the welding current and arc voltage will show corresponding changes. In automated welding applications of welding robots, the relationship between the two is defined as the static characteristics of the welding robot arc welding manipulator.

2. Factors affecting the pressure of gas medium due to the static characteristics of the arc of Yaskawa welding robot

The above definition can generate electricity, electrode material, gas medium, arc length, etc. are closely related to the static characteristics of the arc, under the influence of the pressure of the gas medium around the Yaskawa welding robot, if other parameters remain unchanged, the arc pressure will change due to the change of medium pressure.

3. The influencing factors of the static arc characteristics of Yaskawa welding robot on the arc length

As we all know, the change in arc length refers to the change in the length of the arc column of the Yaskawa welding robot, and at the same time, the length change of the cathode area and anode area is not significant. Once the voltage drop across the arc tower increases, so does the static characteristic position of the arc. In summary, when the current and arc length increase, the arc voltage will increase.

4. The type of gas that affects the arc static characteristics of Yaskawa welding robot

It should be understood that different types of gases result in different ionization energies and thermophysical properties of gases, which can have different effects on the arc voltage. Normally, the thermal conductivity of the gas is stronger when the arc is cooled, so the arc voltage of the Yaskawa welding robot also increases.
Explain in detail the setting method of arc static during welding of Yaskawa welding robot

More on that
Precautions for the use of Yaskawa servo drives Precautions for the use of Yaskawa servo drives

Precautions for driver grounding in the Yaskawa servo drive manual 1. The correct shield grounding point is at the reference potential inside the circuit, which depends on the noise source and reception Whether it is grounded at the same time, or floating. 2. Make sure that the shielding layer is in the same ...

A robot village opened to commemorate the 100th anniversary of Yaskawa Electric A robot village opened to commemorate the 100th anniversary of Yaskawa Electric

Japan's Yaskawa Electric famously created the first all-electric industrial robot, Motoman, in 1977, headquartered in the city of Kita-Kyushu, since its establishment in 1915, has gone from being called "Yaskawa Electric Japan as an automobile manufacturer", "Yaskawa Electric Automation Company of Japan" to "...

Common faults and solutions of Yaskawa inverter Common faults and solutions of Yaskawa inverter

(1) Overcurrent, display character: OC. The reason for tripping is the short circuit of UVW at the output end, the load is too large, the acceleration/deceleration time is set incorrectly or the torque is unreasonable, resulting in overcurrent or overheating of the main circuit module. Check whether there is a short circuit in the motor junction box, whether the motor winding is to the ground, phase to phase ...

Yaskawa Electric restores three plants in Japan on the premise of safety Yaskawa Electric restores three plants in Japan on the premise of safety

Yaskawa Electric recently announced that its soft starter processing plant in Shanghai has resumed production since February 18. So far, the three processing plants of this Japanese-funded processing and manufacturing company in China have been fully opened. Last week, Yaskawa Electric in China processed two other ...

The main recommended models for Yaskawa inverters The main recommended models for Yaskawa inverters

Yaskawa inverter is mainly used in the following series: Low-pressure type V1000: Amazing! A small inverter is controlled using a simple real current vector J1000: High reliability from a compact inverter! Simple operation, simple setting Varispeed ...

Yaskawa servo motor - what are the control methods of servo drive? Yaskawa servo motor - what are the control methods of servo drive?

Servo drive is a kind of controller used to control servo motor, its function is similar to that of an inverter acting on an ordinary AC motor, which is a part of the servo system and is mainly used in high-precision positioning systems. Servo drive is an important part of modern motion control, which is widely used.

Yaskawa inverter - precautions for high-voltage inverter Yaskawa inverter - precautions for high-voltage inverter

1. Carefully monitor and record the display parameters on the man-machine interface of the inverter, and reflect the abnormality immediately 2. Carefully monitor and record the ambient temperature of the inverter room, and the ambient temperature should be between -5 °C and 40 °C. The temperature rise of the phase-shifting transformer should not exceed 130°C 3. Summer ...

Yaskawa inverter installation precautions Yaskawa inverter installation precautions

Precautions for installing Yaskawa inverter   Do not turn on the power supply during wiring operations, otherwise there will be a risk of electric shock. In order to prevent electric shock, please do not operate in the state of removing the inverter cover, otherwise there will be a risk of electric shock. Be sure to ground the ground terminal on the motor side ...

A brief introduction to Yaskawa teach pendant programming A brief introduction to Yaskawa teach pendant programming

The display of the teach-in programmer is a 5.7-inch color display. The available characters are English letters, numbers, symbols, katakana, hiragana, and kanji. In addition, when entering Japanese, you can also convert it to kana kanji by entering romaji.   Rotate [REMOTE] to enter the remote ...

Yaskawa inverter maintenance common sense Yaskawa inverter maintenance common sense

In the process of using various electrical and electronic equipment such as Yaskawa inverters, drives, etc., in addition to strict product related instructions to operate, in order to reduce the maintenance probability of Yaskawa inverters, it is also necessary to do a good job of correct maintenance and maintenance, which is also conducive to reducing the probability of maintenance, thereby reducing the ...

How to wire Yaskawa servo motor B1B2? How to wire Yaskawa servo motor B1B2?

1. First of all, connect the terminal block of Yaskawa servo B1B2, in which the B1 terminal receives the power supply and the B2 terminal receives the signal; 2. Then, connect the terminal block of Yaskawa servo B1B2, wherein B1 terminal receives power supply, and B2 terminal receives signal; 3. After the wiring is completed, ...

Matters needing attention to when disassembling and assembling Yaskawa inverter Matters needing attention to when disassembling and assembling Yaskawa inverter

1. Due to the soft material of the bolt material inside the Yaskawa inverter, if the tool is matched with a large error, it is easy to cause damage to the bolt head, it is recommended to equip the maintenance personnel with special tools of imported or joint venture brands. 2. The electrolytic capacitor and heat sink are made of aluminum alloy.

Yaskawa inverter performance advantages Yaskawa inverter performance advantages

The full name of Yaskawa inverter is "Yaskawa AC inverter governor", which is mainly used in three-phase asynchronous AC motors to control and adjust the speed of the motor. Yaskawa inverter is famous all over the world and has a very high share in the Chinese market for many years. Motor knowledge derived from Yaskawa Electric's input, ...

The cause of the failure of the inverter and its maintenance treatment The cause of the failure of the inverter and its maintenance treatment

One. The type of failure and the reason for the failure 1. The type of failure Faults are divided into power supply faults, internal faults, and load faults. Power failure: There is a fault in the power grid connected by the inverter Internal fault: The failure of the drive itself Load Failure: ...

What could be the cause of the CF failure of Yaskawa inverter? What could be the cause of the CF failure of Yaskawa inverter?

The fault code is CF refers to Control Failure, which reaches the torque limit for more than 3 seconds in the deceleration stop (no PG vector control mode) Possible reasons are: The motor parameters are not set correctly The set value of the torque limit is too small The load inertia is relatively ...

Common fault codes for Yaskawa servo drives Common fault codes for Yaskawa servo drives

A.00 Absolute Data Error The absolute value is wrong or not received A.02 Parameter Interrupt User parameter cannot be detected A.04 Parameter Setting Error The user parameter setting exceeds the allowed value A.10 Overcurrent The power transformer is overcurrent A.30 Regeneration Circuit Check Error Regeneration ...

What is the reason for Yaskawa servo alarm AF5? What is the reason for Yaskawa servo alarm AF5?

1. When the control power supply is put in, it is caused by the failure of the servo unit circuit board, and the servo unit needs to be replaced. 2. When it occurs in servo ON, then it is caused by the failure of the servo unit circuit board or the short-term motor power line, and the servo unit or motor needs to be replaced.

Analysis of fault codes of Yaskawa inverter Analysis of fault codes of Yaskawa inverter

Analysis of the fault code of Yaskawa inverter, for reference only: OC Overcurrent The output current of the inverter exceeds the overcurrent detection value · GF grornd Favlt Grounding The ground current on the output side of the inverter exceeds 50% of the rated output current of the inverter ...

Yaskawa servo manual control motor rotation method Yaskawa servo manual control motor rotation method

1. Open the control panel of Yaskawa Servo and select Manual Mode. 2. Manually rotate the rotor of the motor to calibrate the position of the motor; 3. Press the start button on the panel to let the motor start to rotate; 4. Using the speed adjuster on the panel, adjust the motor ...

Causes and solutions of Yaskawa servo drive fault code R10 Causes and solutions of Yaskawa servo drive fault code R10

1. The acceleration/deceleration time constant is too small. Increase the acceleration/deceleration time constant. 2. The torque limit value set by the controller is too small. Increase the torque limit value. 3. The motor cannot start due to the insufficient torque caused by the drop in power supply voltage. 4. Check the power capacity. ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top