Yaskawa inverter - what are the application fields of low-voltage inverter?

Create Date: 2024-8-30 12:03:23|Source: YASKAWA/Yaskawa

1. Fan

With the continuous development of industry, the application of fans is becoming more and more extensive, especially in the chemical, stone and textile industries. And in the fan design generally has the problem of air volume, when the air volume needs to be adjusted, throttling, that is, the damper adjustment mode, and this is unnecessary loss, after the use of frequency conversion speed regulation, it can be easily adjusted according to the actual needs, due to the removal of unnecessary loss, while improving the power factor, its comprehensive power-saving rate is more than 30%.

2. Speed regulating machinery

In the machinery that needs to regulate the speed, such as: extruder, material feed adjustment, conveyor belt, etc., basically use slip adjustment motor, three-phase commutator motor or DC motor speed regulation, the speed regulation performance of the speed regulation motor is not good, the speed stability is poor, the failure rate is high, and the efficiency is low. However, the structure of DC motor and commutator motor is complex, the failure rate is high, the maintenance cost is high, and sparks will be generated when they work, which is extremely unsafe. The above motor speed regulation stability is poor, such as using asynchronous motor plus frequency conversion governor to replace the above kind of motor, can greatly improve efficiency, power saving, small maintenance, safety, reliability, short return on investment period, to improve the economic benefits of enterprises are extremely beneficial.

Low-pressure inverters are more widely used, such as blowers, conveyors, feeders, mixers, grinders, pulverizers, paper cutters, calenders, extruders, valves, compressors, cooling pedals, plastic machinery, elevators, various textile industries, etc. Large-scale application areas such as paper mills in paper mills, injection molding machines in mold factories, rolling mills in metallurgical plants, and fans, pumps, cranes, oil pipelines in chemical and other industries.
Yaskawa inverter - what are the application fields of low-voltage inverter?

More on that
How to deal with the occurrence of OL2 in Yaskawa inverter How to deal with the occurrence of OL2 in Yaskawa inverter

OL2 is the inverter overload alarm, check whether it is a real overload or a false overload. 1. Test whether the output current of the inverter exceeds the rated current of the inverter, if it exceeds it, it may be the mechanical reason, if it does not exceed the inverter detection circuit is broken, and the false overload is reported. ...

Yaskawa Robotics - Top 10 Trends in the Industrial Robot Automation Industry Yaskawa Robotics - Top 10 Trends in the Industrial Robot Automation Industry

1. The demand for smart sensors is increasing Quality inspection is a key component in all industries. Analyzing everything from food to phone covers ensures that consumers can trust the goods they receive. Smart sensors enable manufacturers to more efficiently handle this ...

Yaskawa inverter installation precautions Yaskawa inverter installation precautions

Precautions for installing Yaskawa inverter   Do not turn on the power supply during wiring operations, otherwise there will be a risk of electric shock. In order to prevent electric shock, please do not operate in the state of removing the inverter cover, otherwise there will be a risk of electric shock. Be sure to ground the ground terminal on the motor side ...

Summary of Yaskawa MOTOMAN Servo Drive Fault Repair Cases (5-7) Summary of Yaskawa MOTOMAN Servo Drive Fault Repair Cases (5-7)

5. After powering on, the LED light of the driver does not light up; Cause of failure: The power supply voltage is too low, less than the minimum voltage value requirement. Solution: Check and increase the supply voltage. 6. When the motor rotates, the LED light flashes; (1) Cause of failure: HALL phase ...

Introduction to Yaskawa inverter fault codes Introduction to Yaskawa inverter fault codes

1. If the fault code on the Yaskawa inverter is UV1, then it means that the low voltage of the main circuit is lower than the low voltage standard of 200V, at this time, we need to check whether there is a problem with the wiring of the power supply; 2. If the fault code appears on the Yaskawa inverter ...

Yaskawa Robotics - technical performance characteristics of dresspacks for industrial robots Yaskawa Robotics - technical performance characteristics of dresspacks for industrial robots

1. Technical performance characteristics of industrial robot dresspack - intelligence The reason why the intelligent type is placed at the back of the Z is because compared with the mainstream demand for robot dresspacks in the market (that is, strong, fast, and accurate), it is not the most urgent for the time being. This also reflects the ...

Yaskawa inverter reports Uv1 fault code solution Yaskawa inverter reports Uv1 fault code solution

Yaskawa inverter Uv1 fault name: main circuit undervoltage If the operation command is not entered (the inverter is stopping), the following conditions occur. 1. The DC voltage of the main circuit is lower than the set value of L2-05 (the detection value of the undervoltage (UV) of the main circuit). 2. 200V class: about 190V ( ...

The operation steps of the Yaskawa robot The operation steps of the Yaskawa robot

1. Turn on the power switch and compressed air switch of Yaskawa robot. 2. Turn on the main power switch on the Yaskawa robot control cabinet. After the robot completes the self-test, press the servo power button to turn on the servo power supply of the motor. Press the teach-in button (TEACH) on the control cabinet to make the machine ...

Types and applications of Yaskawa's high-temperature resistant robot protective clothing Types and applications of Yaskawa's high-temperature resistant robot protective clothing

Yaskawa robot is a kind of industrial robot, which can be applied to various automated production lines according to its specifications and models, and the high-temperature work workshop is a major field where industrial robots are used more, so it needs to be protected by robot protective clothing. The following is a brief introduction to Ontor ...

Yaskawa inverter - the selection step of low-voltage inverter Yaskawa inverter - the selection step of low-voltage inverter

(1) Determine the equipment in terms of working mode, volume and load type; (2) The equipment can be determined in terms of process, functional standards and control requirements; (3) The system is clarified in terms of I/O interface, communication interface, and assembly mode; (4) Summarize all ...

Yaskawa launches new products – the next-generation servo products Σ-X series and the new data collection controller YRM-X Yaskawa launches new products – the next-generation servo products Σ-X series and the new data collection controller YRM-X

  At 10 a.m. on December 23, 2022, Yaskawa Electric held an online new product launch conference and officially released the next-generation servo products Σ-X series and the new data collection controller YRM-X. Advanced and optimized motion performance and digital solutions starting with servo are the two major features of this new product.

Yaskawa inverter - precautions for high-voltage inverter Yaskawa inverter - precautions for high-voltage inverter

1. Carefully monitor and record the display parameters on the man-machine interface of the inverter, and reflect the abnormality immediately 2. Carefully monitor and record the ambient temperature of the inverter room, and the ambient temperature should be between -5 °C and 40 °C. The temperature rise of the phase-shifting transformer should not exceed 130°C 3. Summer ...

The cause and treatment method of Yaskawa servo drive alarm code B32 The cause and treatment method of Yaskawa servo drive alarm code B32

Fault description: Current detection fault 2 Cause: V-phase current detection loop fault Solution: When the power is turned on again and the alarm still occurs, it may be a servo unit failure. Replace the servo unit. Here's how to solve it The supply voltage exceeds the specification range ...

Yaskawa Servo Motor – The difference between a servo motor and a stepper motor Yaskawa Servo Motor – The difference between a servo motor and a stepper motor

1. Different control methods Stepper motor: The rotation angle is controlled by controlling the number of pulses, and one pulse corresponds to one step angle. Servo motor: The angle of rotation is controlled by controlling the length of the pulse time. 2. The workflow is different Stepper Motor: Stepper ...

Common faults and solutions of Yaskawa inverter Common faults and solutions of Yaskawa inverter

(1) Overcurrent, display character: OC. The reason for tripping is the short circuit of UVW at the output end, the load is too large, the acceleration/deceleration time is set incorrectly or the torque is unreasonable, resulting in overcurrent or overheating of the main circuit module. Check whether there is a short circuit in the motor junction box, whether the motor winding is to the ground, phase to phase ...

Part of the configuration process for Yaskawa drives Part of the configuration process for Yaskawa drives

1. "Restore factory settings": Perform a factory reset after power-on to avoid some previously set parameters in the inverter (of course, if it is a new inverter, this problem does not exist). 2. "Set the motor type": whether the motor is an asynchronous motor or the same ...

Yaskawa servo drive failure causes and maintenance treatment Yaskawa servo drive failure causes and maintenance treatment

Yaskawa MOTOMAN servo drive fault repair: 1. The motor runs faster in one direction than in the other; (1) Cause of failure: The phase of the brushless motor is wrong. Solution: Detect or detect the correct phase. (2) Cause of failure: In the absence of ...

Yaskawa servo drive fault code and handling method Yaskawa servo drive fault code and handling method

1. If the fault code on the Yaskawa servo drive is UV1, it means that the low voltage of the main circuit is lower than the low voltage standard of 200V, at this time, we need to check whether there is a problem with the wiring of the power supply; 2. If the ...

Analysis of common fault codes of Yaskawa servo drive Analysis of common fault codes of Yaskawa servo drive

A.020 A.02 User Parameters and Number Check Abnormalities The data of the internal parameters of the servo unit is abnormal A.021 A.02 Parameter Formatting Abnormality The data of the internal parameters of the servo unit is abnormal A.022 A.02 Abnormal system parameters and number check The data of the internal parameters of the servo unit is different ...

What are the fault codes of Yaskawa inverter What are the fault codes of Yaskawa inverter

The fault codes of Yaskawa inverters are as follows: OC overcurrent; PG wiring is disconnected or wiring is incorrect; GF output ground fault ground short circuit ; PUF fuse blowing fuse blowing ; OV Main circuit overvoltage Main circuit overvoltage ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top