The inverter is an electric control equipment that uses frequency conversion technology and microelectronic technology to control and communicate the motor by changing the power supply frequency of the motor operation. The inverter is mainly composed of rectifier (AC to DC), filtering, inverter (DC to communication), braking unit, drive unit, detection unit and microprocessor unit. After changing the frequency of the power supply to achieve the intention of changing the power supply voltage, according to the actual demand of the motor to supply the power supply voltage it needs, and then to achieve the intention of energy saving and speed regulation, in addition, the inverter has many maintenance functions, such as overcurrent, overvoltage, overload maintenance and so on.

                               The difference between overload and overheating of the inverter – Reynolds

What is the difference between overload and overheating of an inverter? The causes of overcurrent are as follows:

First, under normal circumstances, the current trips, and the inverter will show OC problems;

The second is that the inverter module is damaged, and at this time, it will show faults as soon as it is turned on, the module is bad, the output voltage is unbalanced, and the load current rises rapidly;

Third, the increase of load torque is blocked, or the acceleration and deceleration time is set improperly, and the torque changes abruptly, causing the current to rise;

Fourth, there is a mismatch between the motor capacity and the power of the inverter, generally the motor power is too large and the inverter is too small.

Overload maintenance, which is the maintenance measures adopted to prevent the power of the load from being too large; Overcurrent maintenance is a maintenance measure taken to prevent excessive current. Overload tripping sometimes also shows OC problems, sometimes OH problems, OH is overtemperature, inverter heat dissipation is poor, and OH will appear when the temperature rise of the module reaches a certain value. In personal experience, current tripping and overload tripping are the difference above.

The reason for the overcurrent exceeding the limit is that the motor is severely overloaded for a short time or other factors; The reason for the overload is that the overload will cause the temperature rise of the motor to exceed the standard.

The inverter is an electric control equipment that uses frequency conversion technology and microelectronic technology to control and communicate the motor by changing the power supply frequency of the motor operation. In order to maintain the safe operation of the equipment, the inverter will set current over-limit (over-current) maintenance and overload over-limit maintenance during operation. Proactively take appropriate measures such as alarms or shutdowns when the limit is exceeded.

Overcurrent means that the current of the motor (inverter output) exceeds the specified value; Overload is when the load of the motor exceeds the rated power of the motor. The main cause of overcurrent and overload is motor overload. The reason why it is divided into two objectives is as follows:

1. The goals of maintenance are different between the two. The overcurrent is mainly used to maintain the inverter, while the overload is mainly used to maintain the expansion of the motor. Because the capacity of the inverter is generally larger than the capacity of the motor. In this case, when the motor is overloaded, the inverter does not have to be overcurrent.

2. The rate of change of the current is different. Overload maintenance occurs during the operation of the production machinery, and the change rate of the current is generally small: other overcurrents other than overload are often sudden, and the change rate of the current is often large.

3. The method of maintenance is different. Overload maintenance has an anti-time characteristic. Overload maintenance is mainly to prevent the motor from overheating, so it has the "reverse time limit" characteristics similar to that of thermal relays. In other words, if you do not exceed the rated current much, you can agree to operate for a longer time, but if you exceed it more, the time for promised operation will be shortened. In addition, because when the frequency drops, the heat dissipation of the motor becomes poor.

More on that
Introduction to the braking mode of Reynolds inverter Introduction to the braking mode of Reynolds inverter

1. Energy consumption braking: The energy consumption braking method uses the braking resistance set in the DC circuit to absorb the regenerative electric energy of the motor through the chopper and braking resistor, so as to realize the rapid braking of the inverter. 2. Feedback braking: feedback system ...

"RNB6000 frequency conversion governor" was included in the National Torch Program "RNB6000 frequency conversion governor" was included in the National Torch Program

Recently, in the "2012 National Torch Program Project" issued by the Ministry of Science and Technology of the People's Republic of China, the "RNB6000 Frequency Conversion Governor" independently developed by Reynolds was included in the "2012 National Torch Program Project" with its domestic leading skills and efficient energy-saving conversion power.

Soft start uses common faults and solutions - Reynolds Soft start uses common faults and solutions - Reynolds

In the process of daily use of soft starters, it is inevitable to encounter some improper use or failure of soft starters in the process of use 1. The user starts ...

Inverter composition and various functions - Reynolds Inverter composition and various functions - Reynolds

Rectifier circuit: rectify 50HZ communication power into direct current. Frequency conversion circuit: The rectified direct current is inverted into a variable frequency communication current. Control part: control the frequency of communication electricity output by the inverter circuit. Maintenance circuit: maintenance and blockage of overcurrent and phase loss ...

Reynolds inverter parameter settings Reynolds inverter parameter settings

The use of Reynolds inverters in industrial production is very important, in addition to speed regulation, soft start effect, the important thing is to be able to save energy. There are many functional parameters of Reynolds inverter, and there are generally dozens or even hundreds of parameters for users to choose. In practice, it is not necessary to ...

Misunderstanding of inverter control loop wiring - Reynolds Misunderstanding of inverter control loop wiring - Reynolds

1. The wires of the inverter control circuit should be strictly distinguished from the main circuit cable (power line) and placed separately. This effectively prevents the inverter's control circuit from being disturbed by harmonics in the inverter's main circuit. 2. To separate the connection of the inverter from the terminals or contacts of other control circuits, ...

Reynolds universal inverter start-up mode Reynolds universal inverter start-up mode

1. Direct launch The universal inverter insists on starting at the beginning of the time according to the set starting frequency and starting frequency, and then accelerates to a given frequency according to the selected acceleration time Second, the speed of the tracking start Universal inverter ...

The water pump is controlled by a frequency converter – Reynolds The water pump is controlled by a frequency converter – Reynolds

1. The constant pressure water supply of the inverter increases the comfort of water supply by 3 times 2. Constant water pressure, reducing pipe bursts and leakage by 80% 3. High efficiency and energy saving, power saving effect up to 20%-60% (depending on the actual situation) 4. The use of frequency converters can realize multi-point pressure in different time periods.

DCS and PLC and other control cabinets are inspected before leaving the factory DCS and PLC and other control cabinets are inspected before leaving the factory

1. Test preparation: 1. It is necessary to remove all power switches before powering on the PLC control cabinet or IO cabinet. 2. It is necessary to completely cut off the connection between the PLC or DCS card and the outside. All front adapters are to be loosened and raised. 3. Check the power terminal wires and connectors.

Precautions for the use of frequency converters - Reynolds Precautions for the use of frequency converters - Reynolds

In order to ensure the safe, efficient and reliable operation of the inverter, the following keys should be grasped when using the inverter: 1) It is necessary for the grounding terminal of the inverter to be firmly grounded, so as to effectively press the radio frequency disturbance and enhance the reliability of the system: the frequency conversion speed regulation system is best to use independent grounding, grounding resistance...

Use the right power for the inverter – Reynolds Use the right power for the inverter – Reynolds

Low pressure issues The VFD reports a low voltage glitch when the drive's DC link voltage drops below 62% of the nominal level at the high setting (480 Vac) and 50% of the nominal value at the low setting (400 Vac). The +10% and -15% voltage tolerances in most manuals are the ones that claim to be ...

Reynolds drive safety rules and warnings Reynolds drive safety rules and warnings

The high-voltage inverter has been designed with the safety of the user in mind. However, due to the energy storage capacitor installed inside the power unit of the inverter, it may still carry a high voltage after disconnecting the power supply, and some parts generate a lot of heat, so contact is prohibited. When working on or near the inverter, please ...

AC servo motor with inverter control method - Reynolds AC servo motor with inverter control method - Reynolds

Because the inverter and servo are different in performance and function, and the use is not very different, it is not possible: 1) In the case of speed control and torque control, the general frequency converter is not very high, and there are also frequency converters that are used to react signals in the upper position to form a closed loop.

Reynolds inverter code function description Reynolds inverter code function description

F09 second acceleration time 0.10 - 999.9sec; 5.0sec; △ The first acceleration and deceleration parameters and the second acceleration and deceleration parameters are switched by terminal X3 (see F55); F10 second deceleration time 0.10 - 999.9sec; 5.0sec; △ The first acceleration and deceleration parameters and the second acceleration and deceleration parameters ...

Rated current analysis of inverter leakage circuit breaker Rated current analysis of inverter leakage circuit breaker

The output of the inverter is controlled by PWM (pulse width modulation, similar to high-speed switching), so a high frequency leakage current will occur, if you want to install a general leakage disconnect switch on the primary side of the inverter, it is recommended to select a sensitivity current of more than 200mA for each inverter and the action time is 0.1 seconds ...

Water pump inverter pressure adjustment method - Reynolds Water pump inverter pressure adjustment method - Reynolds

Water pump inverter pressure conditioning steps: 1. Open PID closed-loop control; 2. Close the pressure circuit; 3. Set the pressure feedback and set the given pressure; When the pump speed is changed, the outlet pressure can be changed. Adjust the operating frequency of the VFD. The higher the frequency, the higher the pump speed and the higher the pressure. About ...

The inverter protects the motor - Reynolds inverter The inverter protects the motor - Reynolds inverter

1. The output of the inverter for overvoltage maintenance has the function of voltage detection, and the inverter can actively adjust the output voltage, so that the motor does not bear the overvoltage, and the motor runs within the set voltage range. 2. Undervoltage maintenanceWhen the voltage of the motor is lower than 90% of the normal voltage (some are set to 85% ...

The reason for the preferred DC mode in the intermediate link of the inverter - Reynolds The reason for the preferred DC mode in the intermediate link of the inverter - Reynolds

The development of the inverter has experienced a slow and gradual process, and the inverter at the beginning of the first century did not choose this kind of AC-DC: communication to DC and then to communication, but direct AC, no central DC link. This kind of inverter is called alternating frequency converter, and now this kind of inverter is in the ultra-high power ...

Inverter leakage solution - Reynolds Inverter leakage solution - Reynolds

1. The cause of the leakage problem Some sites use frequency converters to control the motor, which will present the problem of leakage, and the leakage voltage ranges from tens of volts to 200 volts. In view of this problem, the reasons for this shortcoming are theoretically expounded and stated as follows. Depend on...

Reynolds inverter parameter problem Reynolds inverter parameter problem

1. What are the factory recovery parameters of Reynolds inverter? N600 = 100 (often press the WR button for 3-5 seconds), it is necessary to be in the shutdown state to be effective. 2. In the parameters of the N308 motor of the inverter, is the [motor leakage inductance reactance] specified sub-leakage inductance or rotor leakage inductance react? Decide...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top