Precautions for the use of frequency converters - Reynolds

Create Date: 2024-8-30 12:03:23|Source: RENLE/RENOLDS

In order to ensure the safe, efficient and reliable operation of the inverter, the following keys should be grasped when using the inverter:

1) It is necessary for the grounding terminal of the inverter to be firmly grounded, so as to effectively press the radio frequency disturbance and enhance the reliability of the system: the frequency conversion speed regulation system is best to use independent grounding, and the grounding resistance is less than 1Ω. The grounding wires such as sensors, I/O interfaces, and shields in the frequency conversion speed regulation system should be independently connected with the grounding busbar of the system.

2) The ambient temperature has a great impact on the service life of the inverter, and the life of the inverter is halved for every 10 °C of the ambient temperature, so the ambient temperature and heat dissipation around the inverter must be dealt with. In order to ensure the safe and reliable operation of the inverter, the inverter should be placed in an air-conditioned environment, the temperature should be controlled at 25 °C±3 °C, and the relative humidity RH should be ≤70%-75%. Practice has proved that the failure rate of the inverter in the air-conditioned environment is much less than that in the air-conditioned environment, and the reliability of the system has also been strengthened.

3) Correct wiring and parameter setting. Before installing the inverter, it is necessary to read its manual carefully to grasp its usage, precautions and wiring; After the inverter is installed according to the technical conditions required by the inverter device, the parameters are correctly set according to the application requirements. It is not advisable to install a communication contactor between the inverter and the driven motor, so as to avoid overvoltage and damage to the inverter at the moment of contactor breaking. The output of the inverter cannot be equipped with a capacitance compensation device to avoid the overheating damage of the capacitor caused by higher harmonics and the malfunction of the inverter's overcurrent maintenance.

                            Precautions for the use of frequency converters - Reynolds

4) The operation and abort of the inverter can not be operated directly by the circuit breaker and contactor, but should be operated by the inverter control terminal or the inverter panel keyboard, otherwise the inverter will be out of control, and the inverter may be damaged.

5) Prevent the use of inverter to drive the motor that does not match its capacity, the small capacity of the motor will affect the output of the torque, and the harmonic weight of the current will increase if the capacity is too large, which will have a negative impact on the frequency conversion speed regulation system. When using one inverter to drive multiple motors, in addition to making the total current of the motor less than the rated current of the inverter, it is also necessary to consider at least the influence of the starting current of the maximum motor to prevent the overcurrent maintenance action of the inverter. When the driven motor is equipped with a brake, the inverter shall operate in the free shutdown mode, and the action signal of the brake shall be announced after the inverter stop command is announced.

6) The selection of the motor and its best working section is a key consideration in the design, if the inverter runs below 5Hz for a long time, the motor heating will become an outstanding problem. When the motor is operated at low speed with the inverter, due to the decline of the cooling effect of the motor, the temperature rise of the motor is too high, which is not conducive to the safe operation of the motor, it is necessary to ensure that the motor has excellent ventilation conditions, and if necessary, the external ventilation and cooling method should be adopted, and the design should prevent the motor from running in the low-frequency area for a long time.

7) The inverter can arbitrarily adjust the speed of the motor, which brings convenience to the conditioning, but each motor has its certain natural frequency, if the speed frequency of the motor is just to meet the production requirements, but just close to the natural frequency of the motor, resonance will occur, bringing severe damage to the motor, therefore. On the premise of satisfying the production requirements, it is necessary to consider avoiding the critical speed of the motor as much as possible.

8) Under the premise of conforming to the design specifications, the length of the cable between the inverter and the motor should be shortened as much as possible to reduce the dispersion capacitance of the cable between the inverter and the motor, so as to reduce the parasitic current during the low-frequency operation of the inverter.

9) It is strictly forbidden to directly measure the insulation resistance of the inverter with the insulation resistance meter, and it is necessary to disconnect the inverter and all weak current components when carrying out the insulation shake test, these components can not be measured by the insulation resistance meter, and the inverter should not be tested for withstand voltage.

10) If the frequency conversion speed regulation system adopts the power frequency and frequency conversion switching mode to operate, the interlock between the power frequency output and the frequency conversion output should be reliable. And when switching between power frequency and frequency conversion, the output of the inverter should be blocked before the contactor is operated. Since it takes a certain amount of time for the contact adhesion and the arc of the high-capacity contactor to be calmed, it is necessary to cooperate optimally in the sequence and time of switching.

11) Install an electromagnetic disturbance filter at the input end of the inverter, which can effectively press the conduction disturbance of the inverter to the power grid, install a communication reactor at the input end of the inverter and install a DC reactor on the DC bus of the inverter, which can improve the power factor, reduce harmonic pollution, and have a good inductive effect. In applications where the interval between the motor and the inverter is more than 100 m, it is necessary to install a communication output reactor at the output end of the inverter to deal with the leakage current caused by the dispersion parameter of the output wire to the ground, so as to reduce the radiation disturbance to the outside.

More on that
Control method of Reynolds inverter Control method of Reynolds inverter

The fulfillment device commonly used in the industrial field of Reynolds inverter has good speed regulation performance and simple and convenient operation method. Therefore, it is widely used in the automation system. Typical wiring method for the main circuit of a Reynolds frequency converter ...

Reynolds EPS emergency power supply routine maintenance Reynolds EPS emergency power supply routine maintenance

1. EPS the first use of the emergency power supply, the battery pack should be charged continuously for 48 hours after discharging protection; 2. EPS emergency power supply to keep the whole machine dry, clean, free of dust and foreign objects, wipe with a soft cloth after shutting down, and strictly ...

Progressive method of robustness of automatic control cabinets – Reynolds Progressive method of robustness of automatic control cabinets – Reynolds

1. Appropriate working environment 1. The ambient temperature is suitable All manufacturers have certain rules for active temperature control cabinets. The PLC promises that the ambient temperature is usually about 0 to 55 ° C, so during the equipment process, this heating element is not placed in the PLC; The PLC should have adequate ventilation and ...

The soft starter output is out of phase fault The soft starter output is out of phase fault

Soft Starter Repair Problem: F 04 (Input Phase Loss): There are several factors that cause this problem, some of which are listed below: (1) Check whether the wiring between the incoming power supply and the motor is loose; (2) Whether the output is connected to the load, and whether the load is matched with the motor; (3) ...

DCS and PLC and other control cabinets are inspected before leaving the factory DCS and PLC and other control cabinets are inspected before leaving the factory

1. Test preparation: 1. It is necessary to remove all power switches before powering on the PLC control cabinet or IO cabinet. 2. It is necessary to completely cut off the connection between the PLC or DCS card and the outside. All front adapters are to be loosened and raised. 3. Check the power terminal wires and connectors.

The heat dissipation method of the switching power supply The heat dissipation method of the switching power supply

1. Transfer heat pipes for heat dissipation. In many applications, heat generated from the base steel plate of the power module is transferred through the heat transfer components to the distant surface of the heat pipe. In this way, the temperature of the base steel plate of the power module will be equal to the temperature of the heat pipe heat dissipation surface, the temperature of the heat transfer parts, and the temperature of the two contact ...

Inverter starts the overload adjustment parameter - Reynolds Inverter starts the overload adjustment parameter - Reynolds

Motor overload: There is no need to set overload maintenance parameters in frequency conversion. The inverter generally acquiesces to the motor overload maintenance based on the motor power. Generally, it is 1.2 times and 60 seconds will report an overload failure. The overload factor is not the same for different frequency converters. ...

Precautions for low-temperature operation of VFD Precautions for low-temperature operation of VFD

1. VFD should be operated in an environment above minus 10°C as much as possible, and it is best to operate indoors. 2. When the VFD is started and stopped, try to start and stop with the VFD itself, do not close the power supply, and keep your VFD in a power-on state. 3. Give VFD l ...

The basic principle of vector control – Reynolds frequency converters The basic principle of vector control – Reynolds frequency converters

The fundamental principle of vector control is to control the excitation current and torque current of the asynchronous motor according to the principle of magnetic field orientation through the measurement and control of the stator current vector of the asynchronous motor, and then to achieve the purpose of controlling the torque of the asynchronous motor. Specifically, it is to ...

Inverter maintenance power-on test instructions - Reynolds Inverter maintenance power-on test instructions - Reynolds

First, the inverter is not repaired and the power test is tested (1) Inverter repair test rectifier circuit At the two ends of the inverter to detect the internal DC power supply, P and N ends, adjust the multimeter to the resistance RX10 gear, the red watch pen is connected to the P end, and the black watch pen is connected to R, S, T, and there are tens of ohms under normal conditions.

Introduction and features of Reynolds soft starters Introduction and features of Reynolds soft starters

Reynolds soft starters include soft starters for high, medium and low voltage motors, including JJR1000 series, JJR2000 series, JJR5000 series, and RNB3000 series frequency converters. Reducing the starting power supply avoids voltage drops and voltage dips in the power supply. Smooth start-up avoids product damage. ...

The cause of bearing noise in different situations of frequency converters - Reynolds The cause of bearing noise in different situations of frequency converters - Reynolds

1. If the bearing is in good continuous rotation condition, it will emit a low whining or humming sound. Sharp hissing, squeaking and other irregular sounds often indicate that the bearing is in a bad continuous rotation condition. The sharp squeaky noise can be due to the formation of an inappropriately smooth ...

Germany core control appeared at the China International Industry Fair Germany core control appeared at the China International Industry Fair

It is human beings who have always been committed to making human-computer interaction safer, easier to use, and more efficient, which has made collaborative robots gradually become the main stream of shopping malls. It is precisely because of the vigorous development of the collaborative robot industry that Synapticon Gmb ...

Inverter breakdown factor – Reynolds Inverter breakdown factor – Reynolds

1. Overpressure leads to brake pipe breakdown. The so-called overvoltage of the inverter refers to the fact that the inverter voltage composed of various reasons exceeds the additional voltage, which is reflected in the DC voltage of the inverter DC bus. Overvoltage alarm generally appears when the machine is shut down, and its main ...

The reason for the large fluctuation of harmonic parameters in the harmonic test of the output harmonic test of the inverter The reason for the large fluctuation of harmonic parameters in the harmonic test of the output harmonic test of the inverter

In order to measure stable harmonics, it is necessary to meet the following two conditions: At the top of the list, the signal is a stable periodic signal. Second, it is necessary to perform harmonic analysis according to the integer multiple of the period of the stable periodic signal. ...

Reynolds inverter FAQ - parameter class Reynolds inverter FAQ - parameter class

1. What are the factory parameters of inverter rehabilitation? N600 = 100 (often press the WR button for 3-5 seconds), it is necessary to be in the shutdown state to be effective. 2. In the parameters of the N308 motor of the inverter, [motor leakage inductance reactance] is the specified sub...

Water pump inverter pressure adjustment method - Reynolds Water pump inverter pressure adjustment method - Reynolds

Water pump inverter pressure conditioning steps: 1. Open PID closed-loop control; 2. Close the pressure circuit; 3. Set the pressure feedback and set the given pressure; When the pump speed is changed, the outlet pressure can be changed. Adjust the operating frequency of the VFD. The higher the frequency, the higher the pump speed and the higher the pressure. About ...

Inverter acceleration and deceleration mode selection Inverter acceleration and deceleration mode selection

The selection of the acceleration form and deceleration form of the inverter is also called the selection of acceleration and deceleration curves. Generally, there are several forms of inverter, such as linear, S-shaped, semi-S-shaped, etc., and the characteristics and uses of each form are as follows. 1. Linear form The form makes the inverter ...

Reynolds servo motor selection steps Reynolds servo motor selection steps

According to the requirements of the operating conditions, the appropriate load inertia accounting formula is selected to calculate the load inertia of the organization. According to the load inertia and servo motor inertia, the appropriate servo motor standard is selected. Combined with the inertia and load inertia of the primary servo motor, the acceleration torque and deceleration are calculated.

Reynolds assisted Sinopec Weirong shale gas project Reynolds assisted Sinopec Weirong shale gas project

With the rapid development of China's national economy, the supply and demand situation of oil and gas resources is becoming increasingly severe, and the import of oil and gas is increasing year by year, so it is urgent to expand the field of domestic oil and gas exploration and development. Strengthening the exploration and development of shale gas resources can make up for the lack of conventional oil and gas resources and promote the sustainability of the oil and gas industry.

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top