Water pump inverter pressure conditioning steps: 1. Open PID closed-loop control; 2. Close the pressure circuit; 3. Set the pressure feedback and set the given pressure; When the pump speed is changed, the outlet pressure can be changed. Adjust the operating frequency of the VFD. The higher the frequency, the higher the pump speed and the higher the pressure. For information on how to operate a variable-frequency drive (VFD), please refer to the operating manual of the product.
So let's talk about how VFD adheres to constant voltage.
The VFD is also the core equipment for constant voltage control. For VFD, either the built-in PID conditioning unit or the intelligent PID manipulator is installed to achieve constant voltage control. The PID manipulator consists of three units: proportion, integration and derivation, which are mainly used to set these three parameters. The PID manipulator adjusts the error of the whole system according to the PID control principle, so that the practical value is consistent with the process requirement value. In simple terms, the manipulator collects data, compares it to a reference value, and then uses the error to calculate a new input value. The purpose of this new input is to keep the system data at the reference value. Not when the practice value is equal to the reference value, but sticks to the reference value. This equilibrium can only be described as a dynamic equilibrium.
In order to provide data collection for PID manipulators, it is necessary to use an imitation of the appearance, i.e. a pressure transmitter. The pressure transmitter plays the role of detection and transmission in the closed-loop conditioning system. The pressure is detected, and then the detected pressure is converted into a current signal to the VFD. The VFD then directly receives the transmitter's analog signal for PID manipulation. Once the pressure changes, the output frequency of the VFD will also change, which will also change the speed of the motor to achieve the purpose of stabilizing the pressure.
Generally, the constant pressure control mode at the outlet of the water pump is selected, and the pressure transmitter is installed at the outlet of the water pump, which reflects the real-time change of water pressure and makes the control effect of the closed-loop conditioning system better.
|
More on that
|
The difference between inverter motor and ordinary motor – Reynolds
Inverter motor - used for special occasions with inverter, it is different from the general motor in that a strong cooling fan is added. And the power of the fan comes from the independent power supply, can not be from the main motor out of the line, the effect of the strong cooling fan is to ensure that the motor at low speed...
|
|
The heat dissipation method of Reynolds switching power supply
1. Transfer heat pipes for heat dissipation.
In many applications, the heat generated from the base steel plate of the power module is transferred through the heat transfer components to the distant heat pipe surface. In this way, the temperature of the base steel plate of the power module will be equal to the temperature of the heat pipe heat dissipation surface, the temperature of the heat transfer parts, and the temperature of the two contact ...
|
|
Reynolds inverter FAQ - parameter class
1. What are the factory parameters of inverter rehabilitation?
N600 = 100 (often press the WR button for 3-5 seconds), it is necessary to be in the shutdown state to be effective.
2. In the parameters of the N308 motor of the inverter, [motor leakage inductance reactance] is the specified sub...
|
|
Calculation of the braking resistance of the inverter – Reynolds
After selecting the resistance value of the braking resistor, the power value of the braking resistor should be confirmed, and the selection of the braking resistor power is relatively cumbersome, and it is related to many factors.
The instantaneous power consumed by the braking resistor is calculated according to the following formula: P instantaneous = ...
|
|
Reynolds drives use the most energy-efficient method
As an electronic electric, the inverter itself also consumes electricity (about 3-5% of the additional power). A 1.5 hp air conditioner consumes 20-30W of electricity, which is equivalent to the length of a lamp. The inverter works under the power frequency and has the function of saving electricity, which is practical.
But the conditions are:
At the top of the list, great success ...
|
|
Precautions for the coordination of PLC and inverter - Reynolds
Under the current production conditions, when the inverter is used to form an automatic control system for control, in many cases, it is necessary to choose PLC and inverter to match the use, such as bearing cleaning, packaging paper printing, PCB board production, etc.
PLC ...
|
|
Frequency converter overcurrent problem treatment - Reynolds
General treatment methods for inverter overcurrent problems:
The output side of the inverter is a PWM voltage waveform, and after passing through the motor winding, the output current is approximately a sine wave, and lags behind the voltage by a phase viewpoint, which is determined by the power factor of the motor. The output current of the inverter passes through ...
|
|
Tips for using reducers - Reynolds
1. After 200-300 hours of operation, the first oil change should be carried out, and the quality of the oil should be checked regularly in the subsequent use, and the oil mixed with impurities or deteriorated oil must be replaced in time. Under normal circumstances, the reducer for long-term continuous operation should be replaced after 5000 hours of operation or once a year.
|
|
Reynolds frequency converters are remotely controlled for wiring
1. Connect X (switching input) drive terminal to control the inverter start-stop/positive rotation;
2. Connect to the AI (analog input) terminal to control the frequency of the inverter (perhaps made into PID closed-loop control automatic adjustment frequency)
3. ...
|
|
Advantages of the inverter vector control system - Reynolds
Dynamic "fast response" DC motors are rectified constrained and excessively high di/dt is not allowed. The asynchronous motor is only constrained by the capacity of the inverter, and the multiple of the forced current can be very high, so the speed echoes quickly, generally reaching the millisecond level, which has surpassed the DC motor in terms of speed.
At low frequencies ...
|
|
Reynolds inverter power selection
The system power is equal to the product of the power of a general-purpose inverter and the power of the motor. As long as both work efficiently, the system power will be higher. From the perspective of power, when choosing VFD power, you should pay attention to the following points:
VFD ...
|
|
Precautions for low-temperature operation of VFD
1. VFD should be operated in an environment above minus 10°C as much as possible, and it is best to operate indoors.
2. When the VFD is started and stopped, try to start and stop with the VFD itself, do not close the power supply, and keep your VFD in a power-on state.
3. Give VFD l ...
|
|
Reynolds inverter manual
Reynolds inverter brochure (partial)
Before installing
When unpacking, it is found that the machine has water or left water traces, indicating that the inverter has been flooded, so please do not install and use it.
When unpacking, it is found that the machine is damaged and deformed or the parts are missing, please do not install and use it, otherwise there will be fault expansion and personnel ...
|
|
Inverter: The right inverter to use - Reynolds
Low pressure issues
The VFD reports a low voltage issue when the drive's DC link voltage drops below 62% of the nominal level at the high setting (480 Vac) and 50% of the nominal value at the low setting (400 Vac).
The +10% and -15% voltage tolerances in most manuals are the ones that claim to be ...
|
|
How to determine the frequency of start-up – Reynolds
Generally, most motors start to speed up from 0Hz, but in some special cases, it is necessary to start directly from a certain frequency. At this time, the frequency output of the VFD at the moment of activation is the activation frequency. In general, you need to set the activation frequency in the following situations.
...
|
|
Reynolds EPS emergency power supply routine maintenance
1. EPS the first use of the emergency power supply, the battery pack should be charged continuously for 48 hours after discharging protection;
2. EPS emergency power supply to keep the whole machine dry, clean, free of dust and foreign objects, wipe with a soft cloth after shutting down, and strictly ...
|
|
Renault is available in a variety of product ranges
JJR1000系列:
JJR1011;JJR1017;JJR1022;JJR1030;JJR1037;JJR1045;JJR1055;JJR1075;JJR1090;JJR1115;JJR1132;JJR1160;JJR1200;JJR1250;JJR1320;JJR1400;JJR1500;JJR1600 ...
|
|
The abnormal installation of the inverter in the power frequency motor leads to hazards
Installing a variable-frequency drive (VFD) on the power frequency motor can complete the precise control and speed regulation of the motor, and improve the power and accuracy of the progressive motor. However, if it is not properly used and used, the following damages may occur:
...
|
|
Centrifugal fan inverter selection method - Renol
1. See if it is energy-saving.
When selecting equipment products, many business managers will take into account the energy-saving embodiment, which is due to the excellent energy-saving embodiment of the product, which can save a lot of money and resources.
|
|
Soft-start starting method – Reynolds
1) Ramp boost soft start. This starting method is simple, does not have current closed-loop control, and only adjusts the conduction angle of the thyristor to make it add a certain function with time. The disadvantage is that because there is no current limit, in the process of motor starting, sometimes a large impulse current is generated.
|
|