The reason for the preferred DC mode in the intermediate link of the inverter - Reynolds

Create Date: 2024-8-30 12:03:23|Source: RENLE/RENOLDS

The development of the inverter has experienced a slow and gradual process, and the inverter at the beginning of the first century did not choose this kind of AC-DC: communication to DC and then to communication, but direct AC, no central DC link. This kind of inverter is called alternating frequency converter, and now this kind of inverter is used in ultra-high power and low-speed speed regulation. Its output frequency scale is: 0-17 (1/2-1/3 input voltage frequency), so it cannot meet the requirements of many applications, and there was no IGBT at that time, only SCR, so the application scale was limited.

                            The reason for the preferred DC mode in the intermediate link of the inverter - Reynolds

The operating principle of the AC inverter is to control the three-phase power frequency power supply through several groups of phased switches to directly generate the required variable voltage variable frequency power supply, its advantage is high power, energy can be convenient back to the power grid, the highest frequency of its largest defect output must be less than the input power frequency 1/3 or 1/2, otherwise the output waveform is too poor, the motor jitter, can not operate. Therefore, the AC inverter has so far limited the low-speed speed regulation occasions, so it has greatly limited its application scale.

A matrix inverter is an alternating direct inverter consisting of nine switching arrays that are directly connected between the three-phase input and output. The matrix converter does not have a central DC link, and the output is composed of three levels, and the harmonic content is relatively small; Its power circuit is simple and compact, and can output a sinusoidal load voltage with controllable frequency, amplitude and phase; The input power factor of the matrix converter is controllable and can operate in four quadrants. Although matrix converters have many advantages, they are difficult to achieve because they do not allow two switches to turn on or off at the same time during the commutation process. The maximum output voltage of the matrix converter can be low, and the high acceptance voltage of the equipment is also a big defect of this type of converter. It is used in wind power generation because the input and output of the matrix converter are not decoupled, i.e. the asymmetry of either the load or the power supply side will affect the other side. In addition, it is necessary to connect the filter capacitor at the input end of the matrix converter, although the capacity of the capacitor is smaller than that of the AC and DC center energy storage capacitor, but because they are communication capacitors, they need to accept the communication current of the switching frequency, and their volume is not small.

Alternating - alternating frequency conversion is direct frequency conversion, one link is missing, but the amount of equipment used is a lot, and the three-phase requires 36 thyristors, and the control is complex. Our teacher pranks that whoever has 36 pipes will be able to graduate immediately. There is also an alternating frequency, which can only be adjusted to the power frequency, which is generally adjusted to 1/3-1/2 of the power frequency, almost 20Hz.

2. AC-DC inverter

Let's change this kind of communication to DC and then to communication, this kind of inverter is called AC-DC inverter. The AC-DC-AC inverter first rectifies the communication current into direct current through the rectifier, and the DC central circuit smooths the output of the rectifier circuit, and then turns the DC current into a communication current with variable frequency and voltage through the inverter.

There are two types:

AC-DC voltage type

AC-DC current type

Among them, the former is widely used, and the current general-purpose inverter is selected for this topology. Its characteristics are: the center is stored and supplied with bus voltage for electrolytic capacitors, the diode is selected for the pre-stage and uncontrolled rectification, which is simple and reliable, and the inverter is selected for three-phase PWM modulation (now the modulation algorithm is a space voltage vector). Because of the selection of a certain capacity of electrolytic capacitors, the DC bus voltage is stable, and as long as the switching sequence (output phase sequence, frequency) and duty cycle (output voltage size) of the inverter IGBT are well controlled, very superior control characteristics can be obtained.

Due to various factors such as control methods and hardware design, voltage inverters are widely used. The traditional current-type AC-DC inverter selects the natural commutation thyristor as the power switch, and its DC side inductance is more expensive, and is used in doubly-fed speed regulation, and the commutation circuit is required when the oversynchronous speed is over-synchronized, and the function is relatively poor under the condition of low slip frequency, and it is not used much in doubly-fed asynchronous wind power generation. The rectifier frequency conversion device of voltage type AC-DC inverter has the excellent characteristics of simple structure, less harmonic content and adjustable power factor of stator and rotor, which can significantly improve the operating state and output power quality of the doubly-fed generator, and the structure completely realizes the separation of the grid side and the rotor side through the DC bus side capacitor. The stator magnetic field directional vector control system of the voltage AC-DC inverter realizes the decoupling control of the active and reactive power of the generator based on the Z high power point tracking of the wind turbine, which is a representative direction of variable speed constant frequency wind power generation.

In addition, there is a parallel AC-DC inverter topology. This structure is mainly connected in parallel through an AC-DC current type and an AC-DC voltage type inverter, the current type inverter is used as the main inverter for power transmission, and the voltage type inverter is used as an auxiliary inverter to compensate for the current type inverter harmonics. This structure has a lower switching frequency for the main inverter and lower switching current for the auxiliary inverter. Compared with the AC-DC voltage inverter mentioned above, this topology has low switching losses and the power of the whole system is relatively high. Its defects are also clear, the use of a large number of power electronic equipment leads to the rise of costs and more complex control algorithms, and the voltage utilization rate of other structures is relatively low.

3 Problems with AC-DC inverters

Although the AC-DC-AC inverter has the advantages of high output frequency and high power factor, there are still many problems that need to be improved:

At that time, high-power and high-voltage power electronic equipment was in the development period, GTO components were facing elimination, and IGBT and IGCT were still to be matured;

The selection of IGCT (or GTO) and IECT converters is still a problem for the maintenance of straight-through short circuits caused by equipment failure; If a straight-through short circuit occurs in the power supply side converter, a short circuit will be formed in the power grid, so it is necessary to choose a high leakage resistance input transformer for the converter, which generally requires 15% or even up to 20%;

The overload of the AC-DC-AC inverter can be reduced when it runs at low frequency, and the overload of the inverter can be halved when it runs below 5Hz.

The voltage change rate of the output PWM modulation voltage waveform of the AC-DC-AC inverter is very high, which is easy to cause insulation fatigue damage of motors and electrical appliances. When the output wire is long, the common mode reflected voltage will generate a high voltage on the motor side, if it is a two-level converter, the peak value of this voltage is twice the DC voltage, if it is a three-level converter, the peak value of this voltage is three times the voltage of the central half;

AC-DC-AC inverter PWM modulation will cause problems such as harmonics, noise, and shaft current.

More on that
Servo drive failure and solution Servo drive failure and solution

1. When the servo motor of the robot is running at a very low speed, it is fast and slow, just like a creeping machine. Low-speed prostrate servo motors are usually caused by low system gain. Please adjust the parameter N.10.N.11.N.12 to adjust the system gain appropriately, or the automatic gain adjustment function of the running driver ...

Two Reynolds technologies were included in the "2020 Water Conservancy Technology Key Promotion Catalogue" Two Reynolds technologies were included in the "2020 Water Conservancy Technology Key Promotion Catalogue"

In May 2020, Reynolds was recommended by relevant departments to apply for the Ministry of Water Resources's "2020 Key Promotion and Guidance Catalogue of Advanced and Practical Water Conservancy Technologies".

Inverter power and box structure selection - Reynolds Inverter power and box structure selection - Reynolds

First, the selection of inverter power The system power is equal to the product of the inverter power and the motor power, and the system power is higher only when both are operating at a higher power. From the perspective of power, when selecting the power of the inverter, we should pay attention to the following points: 1) ...

Abnormal handling of inverter series reactor - Reynolds Abnormal handling of inverter series reactor - Reynolds

Capacitor series reactors generally adopt epoxy glass fiber multi-encapsulated parallel structure, according to the characteristics of the device site, three-phase vertical stacking, three-phase horizontal "△" and three-phase horizontal "-" type distribution. The substation in the southern area ...

Rated current analysis of inverter leakage circuit breaker Rated current analysis of inverter leakage circuit breaker

The output of the inverter is controlled by PWM (pulse width modulation, similar to high-speed switching), so a high frequency leakage current will occur, if you want to install a general leakage disconnect switch on the primary side of the inverter, it is recommended to select a sensitivity current of more than 200mA for each inverter and the action time is 0.1 seconds ...

Difference Between Soft Starter and Inverter – Reynolds Difference Between Soft Starter and Inverter – Reynolds

Soft starters and frequency converters are two completely different products. The inverter is used in the local area where speed regulation is required, and its output not only changes the voltage but also changes the frequency at the same time; A soft starter is actually a voltage regulator, which is used when starting a motor, and the output only changes the voltage and does not change the frequency. Change...

Reynolds inverter parameter problem Reynolds inverter parameter problem

1. What are the factory recovery parameters of Reynolds inverter? N600 = 100 (often press the WR button for 3-5 seconds), it is necessary to be in the shutdown state to be effective. 2. In the parameters of the N308 motor of the inverter, is the [motor leakage inductance reactance] specified sub-leakage inductance or rotor leakage inductance react? Decide...

Precautions for the use of frequency converters - Reynolds Precautions for the use of frequency converters - Reynolds

In order to ensure the safe, efficient and reliable operation of the inverter, the following keys should be grasped when using the inverter: 1) It is necessary for the grounding terminal of the inverter to be firmly grounded, so as to effectively press the radio frequency disturbance and enhance the reliability of the system: the frequency conversion speed regulation system is best to use independent grounding, grounding resistance...

The reason for the large fluctuation of harmonic parameters in the harmonic test of the output harmonic test of the inverter The reason for the large fluctuation of harmonic parameters in the harmonic test of the output harmonic test of the inverter

In order to measure stable harmonics, it is necessary to meet the following two conditions: At the top of the list, the signal is a stable periodic signal. Second, it is necessary to perform harmonic analysis according to the integer multiple of the period of the stable periodic signal. ...

Faulty inverter – Reynolds inverter Faulty inverter – Reynolds inverter

In ancient times, there were ten major tortures, which made people unable to survive and die, and experienced the purgatory of the world; Today, there are ten "tortures" of inverters, and the same can make your inverters suffer. Let's follow the editor to find out which of the top ten "tortures" will make your inverter "worse than dead"! ...

The internal structure of the inverter is the role of Reynolds The internal structure of the inverter is the role of Reynolds

The inverter is mainly composed of rectifier (AC to DC), filtering, inverter (DC to communication), braking unit, drive unit, detection unit and microprocessor unit. The inverter adjusts the voltage and frequency of the output power supply by the internal IGBT break, and ...

Reynolds drives use the most energy-efficient method Reynolds drives use the most energy-efficient method

As an electronic electric, the inverter itself also consumes electricity (about 3-5% of the additional power). A 1.5 hp air conditioner consumes 20-30W of electricity, which is equivalent to the length of a lamp. The inverter works under the power frequency and has the function of saving electricity, which is practical. But the conditions are: At the top of the list, great success ...

The cause of damage to the inverter brake unit - Reynolds The cause of damage to the inverter brake unit - Reynolds

The inverter motor is equipped with a mechanical brake, is the inverter motor in the power generation condition when parking? Is the brake unit of the inverter working at the moment? What are the causes of brake unit damage? Answer: 1. The inverter motor is equipped with a mechanical brake, and when parking...

The working principle of the motor soft starter – Reynolds The working principle of the motor soft starter – Reynolds

Motor soft starter is the primary selection of power electronics skills and microprocessing skills and modern control theory and design and production of advanced level of new engine equipment, motor soft starter mainly has anti-interference function, high reliability, multiple protection functions and other characteristics, according to these characteristics of electric ...

AC servo motor with inverter control method - Reynolds AC servo motor with inverter control method - Reynolds

Because the inverter and servo are different in performance and function, and the use is not very different, it is not possible: 1) In the case of speed control and torque control, the general frequency converter is not very high, and there are also frequency converters that are used to react signals in the upper position to form a closed loop.

Introduction to the appearance of Reynolds inverter Introduction to the appearance of Reynolds inverter

Bypass cabinet: The cabinet is equipped with high-voltage inlet and outlet isolation switches QS1 and QS2, as shown in Figure 2. Among them, QS1 is a single-pole single-throw variable frequency incoming knife switch, and QS2 is a single-pole double-throw power frequency and variable frequency outgoing knife switch. The bypass cabinet is a high-voltage environment, please observe the live display and electromagnetic lock status to ensure that the ...

The inverter cannot adjust the frequency solution - Reynolds The inverter cannot adjust the frequency solution - Reynolds

In the course of inverter repairs, if there is no significant damage to the hardware and the maximum torque of the VFD is usually less than the torque of the load increase. It means that the load capacity of the frequency conversion speed control equipment has decreased significantly. So how do you deal with this? ...

Reynolds soft starter fault code and fault handling Reynolds soft starter fault code and fault handling

Reynolds soft starter fault code Instantaneous stop -F 01 Instantaneous stop terminal 7 to terminal 10 open TOO LONG STARTING TIME -F 02 STARTING TIME IS TOO LOW AND THE STARTING TIME IS TOO LONG (GREATER THAN 60S) Overheating -F 03 Start too often, reduce the number of starts Input out of phase -F 04 ...

Lightning protection measures for Reynolds frequency converters Lightning protection measures for Reynolds frequency converters

The lightning protection measures of the inverter equipment are another important peripheral measure to ensure the safe operation of the inverter, especially in the area where lightning is active or in the lively season, this problem is particularly important. Today's inverter products are generally equipped with mines.

The structure of the low-voltage circuit breaker - Reynolds The structure of the low-voltage circuit breaker - Reynolds

Low-voltage air circuit breaker, also known as active air switch or air switch, belongs to the switch electrical appliance, is used when the circuit is overloaded, short circuit and undervoltage can actively break the circuit of the electrical appliances, can also be used as infrequent start of the motor or opening and closing circuit, low-voltage air circuit breaker has an all-round circuit breaker ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top