Introduction to the braking mode of Reynolds inverter

Create Date: 2024-8-30 12:03:23|Source: RENLE/RENOLDS

1. Energy consumption braking: The energy consumption braking method uses the braking resistance set in the DC circuit to absorb the regenerative electric energy of the motor through the chopper and braking resistor, so as to realize the rapid braking of the inverter.

                               Introduction to the braking mode of Reynolds inverter

2. Feedback braking: The feedback braking method uses active inverter technology to invert the regenerative electric energy into alternating current at the same frequency and phase as the power grid and send it back to the power grid, and then realize braking. To achieve energy regenerative braking, it requires conditions such as voltage and in-phase control at the same frequency and in phase, and feedback current control.

3. DC braking: DC braking, generally refers to when the output frequency of the inverter is close to zero and the motor speed is reduced to a certain value, the inverter redirects to the stator winding of the asynchronous motor to enter the DC to form a stop magnetic field. It can be used in situations where accurate parking is required or for irregular rotation of the brake motor before starting due to external factors.

4. DC feedback braking: the principle of the shared DC bus feedback braking method is: the regenerative energy of motor A is reflected on the common DC bus, and then its regenerative energy is consumed by motor B; The shared DC bus feedback braking method can be divided into two methods: shared DC balanced bus feedback braking and shared DC loop bus feedback braking.

More on that
Reynolds soft starter problem solving Reynolds soft starter problem solving

1. The soft starter does not start and the fault-free code appears, perhaps because the control power supply is not connected, the solution is to check the power supply of the control power supply to see if the circuit connection is correct. 2. The motor starts when the motor announces a hum/no start signal, perhaps because of the thyristor/module ...

Frequency conversion cabinet external conduit wiring method - Reynolds Frequency conversion cabinet external conduit wiring method - Reynolds

When it is required to wiring outside the frequency conversion cabinet, it is generally necessary to use the conduit for wiring, which requires suitable mechanical pressure and unsuitable mechanical damage, moisture-proof and corrosion-resistant. Conduits include the following two wiring methods: 1. Kim ...

Reynolds high-speed permanent magnet synchronous motor dedicated driver Reynolds high-speed permanent magnet synchronous motor dedicated driver

The state proposes to "peak carbon emissions" by 2030 and complete "carbon neutrality" by 2060. Carbon neutrality is to try to reduce carbon dioxide emissions, and eventually achieve net zero emissions, that is, to make carbon dioxide emissions even offset. However, due to economic development, CO2 emissions are stable ...

The relationship between Reynolds motion control and frequency converters The relationship between Reynolds motion control and frequency converters

Motion control has obvious period characteristics, it is a variety of high-tech generalization, used to push industrial automation, office automation and home automation to a higher stage. Nowadays, motion control is mainly composed of variable frequency drive (VFD), electric motor, control ...

Advantages of frequency converters over soft start – Reynolds Advantages of frequency converters over soft start – Reynolds

(1) The starting torque is large and the power factor is high. Because the power factor of the motor is related to the working frequency, the power factor under the power frequency power supply is much lower than that under the low-frequency power supply when the motor is running at low speed. The inverter can control the motor from low frequencies and ...

Introduction to the appearance of Reynolds inverter Introduction to the appearance of Reynolds inverter

Bypass cabinet: The cabinet is equipped with high-voltage inlet and outlet isolation switches QS1 and QS2, as shown in Figure 2. Among them, QS1 is a single-pole single-throw variable frequency incoming knife switch, and QS2 is a single-pole double-throw power frequency and variable frequency outgoing knife switch. The bypass cabinet is a high-voltage environment, please observe the live display and electromagnetic lock status to ensure that the ...

The difference between frequency converter and power saver - Reynolds The difference between frequency converter and power saver - Reynolds

Many people don't have a clear idea of the detailed differences and uses of AC converters and power savers. Power savers are generally divided into lighting appliances and power savers. Using high-voltage filtering and energy absorption skills, it automatically absorbs the energy of the reverse potential of high-voltage power equipment, and continuously feeds back ...

The working principle of the motor soft starter – Reynolds The working principle of the motor soft starter – Reynolds

Motor soft starter is the primary selection of power electronics skills and microprocessing skills and modern control theory and design and production of advanced level of new engine equipment, motor soft starter mainly has anti-interference function, high reliability, multiple protection functions and other characteristics, according to these characteristics of electric ...

The inverter prepares the braking resistance factor – Reynolds The inverter prepares the braking resistance factor – Reynolds

The preparation of the braking resistor of the inverter is mainly to consume part of the energy on the DC bus capacitor through the braking resistor to avoid the capacitor voltage being too high. Theoretically, if the capacitor stores a large amount of energy, it can be used to release it to drive the motor and avoid energy waste. However, the capacitance of the capacitor is ...

The Reynolds SVG series was successfully completed The Reynolds SVG series was successfully completed

More than 40 sets of RNSVG series low-voltage power generator sets and RNZB series high-voltage reactive power automatic compensation devices designed and produced by Reynolds have been successfully completed and will be delivered in the near future. This product is owned by Shanghai Reynolds ...

Water pump inverter pressure adjustment method - Reynolds Water pump inverter pressure adjustment method - Reynolds

Water pump inverter pressure conditioning steps: 1. Open PID closed-loop control; 2. Close the pressure circuit; 3. Set the pressure feedback and set the given pressure; When the pump speed is changed, the outlet pressure can be changed. Adjust the operating frequency of the VFD. The higher the frequency, the higher the pump speed and the higher the pressure. About ...

Inverter leakage solution - Reynolds Inverter leakage solution - Reynolds

1. The cause of the leakage problem Some sites use frequency converters to control the motor, which will present the problem of leakage, and the leakage voltage ranges from tens of volts to 200 volts. In view of this problem, the reasons for this shortcoming are theoretically expounded and stated as follows. Depend on...

"RNB6000 frequency conversion governor" was included in the National Torch Program "RNB6000 frequency conversion governor" was included in the National Torch Program

Recently, in the "2012 National Torch Program Project" issued by the Ministry of Science and Technology of the People's Republic of China, the "RNB6000 Frequency Conversion Governor" independently developed by Reynolds was included in the "2012 National Torch Program Project" with its domestic leading skills and efficient energy-saving conversion power.

Reynolds inverter power selection Reynolds inverter power selection

The system power is equal to the product of the power of a general-purpose inverter and the power of the motor. As long as both work efficiently, the system power will be higher. From the perspective of power, when choosing VFD power, you should pay attention to the following points: VFD ...

Features of Reynolds high-voltage frequency converters Features of Reynolds high-voltage frequency converters

RNVH-A series high-voltage inverter adopts multi-unit series multi-level technology, which is attributed to high-high voltage source inverter, which can directly input 6KV/10KV and direct 6KV/10KV output. Taking the 6KV series as an example, each phase is connected in series by 5 power units, and each power unit is isolated by the input transformer.

Frequency converter soft troubleshooting – Reynolds Frequency converter soft troubleshooting – Reynolds

Undervoltage is also a problem that we often encounter in application. Mainly because the voltage of the main circuit is too low (220V series is lower than 200V, 380V series is lower than 400V), the main reason: a certain way of the rectifier bridge is damaged or there is abnormal operation in the three ways of the thyristor, which may lead to the appearance of undervoltage problems, ...

Structural characteristics of Reynolds RHY series inverter governor Structural characteristics of Reynolds RHY series inverter governor

1. Advanced technology: (PC or PLC) is used to make the equipment complete the intelligent constant pressure variable supply water supply according to the requirements of water supply and fire protection; 2. High efficiency and energy saving: the system can set the pressure according to the demand, and the system can actively adjust according to the set pressure.

Classification and working principle of Reynolds inverter Classification and working principle of Reynolds inverter

Classification of Reynolds frequency converters: There are many classification methods for Reynolds inverters, which can be divided into voltage-type inverters and current-type inverters according to the classification of the main circuit operation method; According to the classification of switching methods, it can be divided into PAM operation.

Fault signal of the frequency converter - Reynolds frequency converter Fault signal of the frequency converter - Reynolds frequency converter

There are three types of fault signals for the inverter: (1) Excessive mechanical load: The primary feature of excessive load is that the motor heats up, and the operating current can be read from the display screen to find. The primary reason is that the load of the inverter is too large, and the acceleration and deceleration time and operation cycle time are too short; V/F ...

The inverter protects the motor - Reynolds inverter The inverter protects the motor - Reynolds inverter

1. The output of the inverter for overvoltage maintenance has the function of voltage detection, and the inverter can actively adjust the output voltage, so that the motor does not bear the overvoltage, and the motor runs within the set voltage range. 2. Undervoltage maintenanceWhen the voltage of the motor is lower than 90% of the normal voltage (some are set to 85% ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top