Conventional domestic travel switch
LX19-001/111 in the LX19 series, LXK3-20S/T in the LXK3 series, JLXK1 series JLXK1-111/411/511 in the conventional travel switch are the most representative, these products have the advantages of simple structure, practical function and low price, and are favored by the majority of users.
Inlet travel switch
Imported travel switches WL series, HL series, D4V series, SZL-WL series are the most representative, such products have fine workmanship, superior performance, and more outstanding performance in extreme environments, which has won a large number of fans, but the high price also makes many users staggered
High temperature resistant travel switch
The most influential among the domestic high-temperature travel switches is the YNTH series high-temperature travel switches, which are generally used in steel mills. YNTH travel switch can work normally in a high temperature environment, the maximum working temperature is 350 degrees, the temperature of the working environment increases, the life of the product will decrease accordingly, more than 300 degrees to reduce the workload of the switch to ensure the life of the product. This series of travel switches have low price and stable performance, and have won unanimous praise from our customers.
Waterproof travel switch
Among the domestic waterproof travel switches, the YNFS (TZ) series is more prominent. YNFS travel switches have the characteristics of small size, high sensitivity, strong sealing, oil resistance and corrosion resistance, and the most amazing thing is that this kind of travel switch can be placed in water to work in the dust.
According to its structure, the travel switch can be divided into direct-acting, roller-acting, micro-acting and combined.
Direct-acting travel switch
The principle of action is similar to that of a button, except that one is manual and the other is collided by a bumper of moving parts. When the collision block on the external moving parts touches the button to make the contact action, when the moving parts leave, under the action of the spring, the contact automatically resets.
Its structural principle is shown in Figure F1, and its action principle is the same as that of the button switch, but the opening and closing speed of its contacts depends on the running speed of the production machinery, and it is not suitable for use in places where the speed is less than 0.4m/min. When the operating speed is less than 0.4m/min, the speed of contact breaking will be slow, and the contact is susceptible to arc cautery.
Direct-acting travel switch is composed
1: Actuator 2&4: Spring 3: Dynamic breaking contact 5: Moving contact
Roller type travel switch
When the baffle (bumper) of the motion machinery is pressed on the roller of the travel switch, the transmission bar rotates together with the rotating shaft, so that the cam pushes the bumper, and when the bumper hits a certain position, the micro switch is pushed to act quickly. When the stopper on the roller is removed, the return spring resets the travel switch. This is a single-wheel automatic recovery type travel switch. The two-wheel rotary travel switch cannot be automatically restored, it relies on the movement of the machine to move in the opposite direction, the retaining iron hits another roller to restore it.
When the collider on the controlled machinery hits the striker bar with a roller, the striker bar turns to the right, drives the cam to rotate, pushes down the pushrod, and makes the contacts in the micro switch move rapidly. When the moving machinery returns, under the action of the return spring, the action parts of each part are reset.
Roller type travel switch composition
1: Roller 2: Upper swivel arm 3&5&11: Spring 4: Sleeve
6: Pulley 7: Pressing plate 8&9: Contact 10: Transverse plate
The roller travel switch is divided into a single roller automatic reset and a double roller (horn type) non-automatic reset type, and the double roller travel switch has two steady-state positions, which has a "memory" effect, and can simplify the circuit in some cases.
Microswitch type travel switch
The composition of the micro switch type travel switch, taking the commonly used LXW-11 series products as an example, its structural principle is shown in Figure F3:
1: Actuator 2: Spring 3: Moving contact 4: Moving breaking contact 5: Compression spring
By application
General purpose travel switches: such as JW2, JW2A, LX19, LX31, LXW5, 3SE3 and other series. It is mainly used for the limit and program control of machine tools and other production machinery and automatic production lines.
Travel switches for lifting equipment, such as LX22, LX33 series. It is mainly used to limit the stroke of lifting equipment and various metallurgical auxiliary machinery.
|
More on that
|
Siemens APT Relays – Maintenance of high-voltage relays
1. Regular cleaning: The relay needs to be cleaned regularly with dust and dirt to keep its surface clean and smooth. It can be cleaned with a clean cloth or brush, and detergents containing acids and bases should be avoided.
2. Check the wiring: The wiring of the relay needs to be fastened firmly, and the contact ...
|
|
Siemens APT relays – classified according to the protection characteristics of the relays
(1) Sealed relay: Relay with low leakage rate by welding or other methods to seal the contacts and coils in the cover and isolate them from the surrounding medium.
(2) Enclosed relay: A relay that is sealed (not sealed) with a cover to protect the contacts and coils. ...
|
|
Siemens APT relay - common faults and solutions for high-voltage relays
1. Poor contact
Poor contact is one of the most common faults in high-voltage relays, which can lead to problems such as hot terminals ® and burned contacts. Workarounds include regularly checking terminals and set screws for loose and cleaning contact surfaces.
2. Excessive wear
At...
|
|
Siemens APT current transformer – precautions for current transformers
1. Before the installation of the open current transformer, it must be connected to the meter (or other measuring devices) for the second time to ensure that the transformer is not open for the second time;
2. Place all the open current transformers connected to the secondary line on the site and wait for installation;
3. If the on-site bus is electrical...
|
|
AD16-30JC Series Combination Light FAQ
1. What are the basic combination colors of combination lights?
Red, yellow, green, blue, white, bicolor.
2. What are the different types of combination light panes?
F, H, L, V, G any combination
3. Is the lampshade detachable?
OK
4. Combination light ...
|
|
Siemens APT LA39 series button FAQ
1. What are the installation methods of LA39-A/B/C button?
There are five types in total: the Z1 diagonal screw unit, the Z2 straight screw unit, the Z3 nut device with fastening screws, the Z4 nut device without fastening screws, and the Z5 quick and convenient one-handed device
2. LA39 series products can be used ...
|
|
Siemens APT Relays - Maintenance Methods for Solid State Relays
1. The influence of the ambient temperature
The load capacity of the solid state relay is greatly affected by the ambient temperature and its own temperature rise, during the use of the device, it should be ensured that it has good heat dissipation conditions, the rated working current of more than 10A products should be equipped with radiators, and the products above 100A should be dissipated.
|
|
Siemens APT Relays – What are the forms of protection relays?
Rail protection relays
A protective relay that works mainly as a result of accidents that occur in transmission lines. When this method works, the circuit breakers at both ends of the faulty line will be disconnected.
Busbar protection relays
A protective relay, mainly due to the power plant or transformer...
|
|
Siemens APT current transformer - inspection content of current transformer
1. Regularly check whether the current transformer is overheated, check whether there is discoloration in the terminal, and check whether there are sundries in the terminal box.
2. Check whether there is oil leakage in the oil level gauge in time to ensure that the oil level meets the use standard and there is no oil leakage.
|
|
Siemens APT Relays – classified by their operating principle or structural characteristics
(1) Electromagnetic relay: an electrical relay that works by using the suction force generated by the current in the input circuit between the electromagnet core and the armature.
(2) Solid relay: refers to a kind of relay in which electronic components perform their functions without mechanical motion components, and the input and output are isolated.
|
|
Siemens APT Relays – Reliability of Relays
1. The influence of the environment on the reliability of the relay: the average time between failures of the relay is the highest under GB and SF, reaching 820,000h, while in the NU environment, it is only 60,000h.
2. The influence of quality grade on the reliability of relays: when the relay of A1 quality grade is selected, the flat ...
|
|
Siemens APT - AD16 series indicator frequently asked questions
1. Why does the indicator light still glow after the control power supply has been disconnected?
This situation is caused by the presence of interference voltage, and this problem can be solved by ordering our anti-interference indicator light
2. What are the operating hours of the AD16 series indicators?
More than 30000 small ...
|
|
Siemens APT warning light - the role of LED warning light in life
LED warning light function
1. The luminous method selection items are: solid light, shiny, burst flash, constant/shiny mix.
2. The installation base is: L rod, straight rod, folding, and barrel type.
Effect of LED warning light_Effect in different scenes
1. Construction unit
On the road ...
|
|
Introduction to the advantages and disadvantages of Siemens APT relays - solid state relays
merit
1. High life, high reliability: solid state relay has no mechanical parts, the contact function is completed by solid devices, because there are no moving parts, so it can work in a high impact and vibration environment.
|
|
Siemens APT transformer - the use of voltage transformer and precautions
The voltage transformer output is usually 100V
1. The working impedance in the secondary circuit of the voltage transformer should not be too small to avoid overload operation.
2 Before connecting the circuit, the polarity of the voltage transformer should be verified.
3 After connecting the circuit, the secondary coil should be reliably grounded, ...
|
|
Siemens APT transformer – common faults and analysis of voltage transformers
(1) The insulation between the iron chips is damaged
Problem: The temperature rises during operation.
Possible causes of the problem:
(1) Poor insulation between iron chips
(2) The use of harsh environmental conditions or long-term operation at high temperature to promote the aging of insulation between iron chips.
( ...
|
|
Introduction to the characteristics of Siemens APT relays - solid state relays
Solid state relay is a non-contact electronic switch with isolation function, no mechanical contact parts in the switching process, so in addition to having the same function as electromagnetic relay, solid state relay also has logic circuit compatibility, vibration resistance and mechanical impact resistance, unlimited installation position, and good anti-...
|
|
Siemens APT Pushbutton Switches – How Many Types of Pushbutton Switches Are There?
There are several types of pushbutton switches:
Pushbutton switches can be classified according to the way they are protected and how they are operated. It can be divided into open type and protected type, as well as waterproof type and anti-corrosion type, etc. And explosion-proof, knob-type, key-type, emergency-type, are also its ...
|
|
Siemens APT current transformers – precautions for the use of current transformers
1) The wiring of the current transformer should comply with the principle of series connection: that is, the primary winding resistance should be connected in series with the tested circuit, while the secondary winding resistance should be connected in series with all instrument loads
2) According to the size of the measured current, select the appropriate transformation ratio, otherwise the error will increase. At the same time, one end of the secondary side must be grounded in case ...
|
|
Siemens APT Relays – The difference between solid state relays and intermediate relays
First, the solid-state relay has no contacts and coils in the structure, which can be opened and closed at a high frequency and will not produce sparks, and has a long service life;