Siemens APT relays – classified according to the protection characteristics of the relays

Create Date: 2024-8-30 12:03:23|Source: APT/Siemens Shanghai Ergong

(1) Sealed relay: Relay with low leakage rate by welding or other methods to seal the contacts and coils in the cover and isolate them from the surrounding medium.

(2) Enclosed relay: A relay that is sealed (not sealed) with a cover to protect the contacts and coils.

(3) Open relay: Relays that do not use protective covers to protect electric shocks and coils, etc.

The most commonly used relays in electronic production are electromagnetic relays and reed relays.
Siemens APT relays – classified according to the protection characteristics of the relays

More on that
Siemens APT Relays – Testing of Relays Siemens APT Relays – Testing of Relays

(1) Measure the resistance of the contact: use the resistance of the multimeter to measure the resistance of the normally closed contact and the moving point, and the resistance value should be 0; The resistance between the normally open contact and the moving point is infinite. From this, it is possible to distinguish which is a normally closed contact and which is normally open. (2) Coil resistance: multimeter R...

Siemens APT current transformer - working principle and characteristics of current transformer Siemens APT current transformer - working principle and characteristics of current transformer

How a current transformer works The principle of current transformer is based on the principle of electromagnetic induction. A current transformer is composed of a closed core and windings. It has a small number of turns on the primary side winding, stringed in the line where the current needs to be measured, so it often has the full current of the line ...

Siemens APT Relays – classified by their operating principle or structural characteristics Siemens APT Relays – classified by their operating principle or structural characteristics

(1) Electromagnetic relay: an electrical relay that works by using the suction force generated by the current in the input circuit between the electromagnet core and the armature. (2) Solid relay: refers to a kind of relay in which electronic components perform their functions without mechanical motion components, and the input and output are isolated.

Siemens APT Limit Switches - Introduction to the types and characteristics of limit switches Siemens APT Limit Switches - Introduction to the types and characteristics of limit switches

Conventional domestic travel switch LX19-001/111 in the LX19 series, LXK3-20S/T in the LXK3 series, JLXK1 series JLXK1-111/411/511 in the conventional travel switch are the most representative.

Siemens APT Relays – The Difference Between Solid State Relays and AC Contactors Siemens APT Relays – The Difference Between Solid State Relays and AC Contactors

1. First of all, solid-state relays have a long service life and strong reliability. The solid state relay corresponds to the CDG1 series delicacy. This solid-state relay has no mechanical parts and solid-state devices to complete the contact function. Since the parts do not move, they can work in high shock and vibration environments. Because...

Siemens APT - ALS series limit switch FAQ Siemens APT - ALS series limit switch FAQ

1. What are the installation methods of ALS limit switches? Usually the limit switch is divided into front of the board installation or board back installation, all of which are installed by screws. 2. What are the different modes of limit switch action? According to the action mode of the limit switch head, it is divided into ...

Siemens APT Relays – What should I pay attention to when selecting relays? Siemens APT Relays – What should I pay attention to when selecting relays?

1. When selecting a relay, it is necessary to understand the load and type of its contact, because the contact method of the relay of the same model is different, with multiple groups of contacts and single group contacts. When selecting a relay, you can choose the type of contact. 2. And in the peach ...

Siemens APT Relays – What are the types of protection relays? Siemens APT Relays – What are the types of protection relays?

Overcurrent Relay (OCR) It operates when a certain value or greater of current flows through. There are two elements: overcurrent detection (known as a timing element) and short-circuit current detection (as an instantaneous element). Earth Fault Overcurrent Relays (OCGR, GR) While...

Siemens APT Relays - the main product technical parameters of relays Siemens APT Relays - the main product technical parameters of relays

(1) Rated working voltage: refers to the voltage required by the coil when the relay is working normally. Depending on the type of relay, it can be either AC voltage or DC voltage. (2) DC resistance: refers to the DC resistance of the coil in the relay, which can be measured by a multimeter. ...

Siemens APT Pushbutton Switches - Introduction to the types of metal pushbutton switches Siemens APT Pushbutton Switches - Introduction to the types of metal pushbutton switches

Common types of metal button switches include self-locking switches, self-reset switches, knob gear switches, lever gear switches, locking switches, etc.; Because the metal button switch is small in size, easy to install, metal material, voltage can be used from 9-220V, and the appearance of metal texture ...

Siemens APT Relays – Principles and characteristics of photorelays Siemens APT Relays – Principles and characteristics of photorelays

When the input quantity (such as voltage, current, temperature, etc.) reaches the specified value, the controlled output circuit is turned on or off an electrical appliance. It can be divided into two categories: electrical (such as current, voltage, frequency, power, etc.) relays and non-electrical (such as temperature, pressure, speed, etc.) relays. With action ...

Siemens APT relay - common faults and solutions for high-voltage relays Siemens APT relay - common faults and solutions for high-voltage relays

1. Poor contact Poor contact is one of the most common faults in high-voltage relays, which can lead to problems such as hot terminals ® and burned contacts. Workarounds include regularly checking terminals and set screws for loose and cleaning contact surfaces. 2. Excessive wear At...

Siemens APT Pushbutton Switches – How Many Types of Pushbutton Switches Are There? Siemens APT Pushbutton Switches – How Many Types of Pushbutton Switches Are There?

There are several types of pushbutton switches: Pushbutton switches can be classified according to the way they are protected and how they are operated. It can be divided into open type and protected type, as well as waterproof type and anti-corrosion type, etc. And explosion-proof, knob-type, key-type, emergency-type, are also its ...

Siemens apt - TL series police lights frequently asked questions Siemens apt - TL series police lights frequently asked questions

1. How many light sources are there for the TL-70 police light? There are 3 types, namely LED, incandescent and xenon. 2. What are the colors of the TL-70 police light? There are 5 types, which are red, yellow, green, blue, and white. 3. What are the types of TL-70 police lights? 3 ...

Siemens APT Relays – a commonly used detection method for high and low voltage relays Siemens APT Relays – a commonly used detection method for high and low voltage relays

1. Visual inspection method: observe the appearance of the relay by the naked eye, check whether it is damaged or deformed, observe whether the contacts are tightly contacted, and whether there are copper slag and other substances attached to the contacts. 2. Parameter detection method: use test instruments to detect the parameters of the relay, such as: ...

Siemens APT Relays - Installation Precautions for High and Low Voltage Relays Siemens APT Relays - Installation Precautions for High and Low Voltage Relays

1. Choose the right relay: When choosing a high and low voltage relay, you should choose the right product according to your needs, such as selecting according to the rated voltage, current and other information 2. Installation location: high and low voltage relays should be installed in dry, ventilated, non-corrosive gas, less dusty areas, ...

Siemens APT Relays – Analysis of Common Faults and Causes of Relays Siemens APT Relays – Analysis of Common Faults and Causes of Relays

1. Overhaul of the sensing mechanism For electromagnetic (voltage, current, intermediate) relays, the sensing mechanism is the electromagnetic system. The faults of the electromagnetic system are mainly concentrated in the coil and the moving and static iron cores. (1) Coil fault maintenance Coil failure usually has a coil absolute...

Siemens APT LA39 series button FAQ Siemens APT LA39 series button FAQ

1. What are the installation methods of LA39-A/B/C button? There are five types in total: the Z1 diagonal screw unit, the Z2 straight screw unit, the Z3 nut device with fastening screws, the Z4 nut device without fastening screws, and the Z5 quick and convenient one-handed device 2. LA39 series products can be used ...

Introduction to the features of Siemens APT DY2 miniature relay Introduction to the features of Siemens APT DY2 miniature relay

Various specifications, with indicator light, with manual test button, with surge suppression loop and other functions Coil control voltage DC6V-220V, AC6V-240V(50/60HZ) The rail type is equipped with a variety of adapting sockets LED indicator, DC is green, AC is red Illuminating...

Siemens APT Relays – What are the forms of protection relays? Siemens APT Relays – What are the forms of protection relays?

Rail protection relays A protective relay that works mainly as a result of accidents that occur in transmission lines. When this method works, the circuit breakers at both ends of the faulty line will be disconnected. Busbar protection relays A protective relay, mainly due to the power plant or transformer...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top