1. What are the installation methods of LA39-A/B/C button?
There are five types in total: the Z1 diagonal screw unit, the Z2 straight screw unit, the Z3 nut device with fastening screws, the Z4 nut device without fastening screws, and the Z5 quick and convenient one-handed device
2. Can the LA39 series be used at high altitudes?
It can be used normally within 2000m above sea level, and needs to be used in capacity reduction if it exceeds 2000m.
3. What is the difference between snap-acting and slow-acting contacts?
The structure is not the same. Slow-acting contact: the contact has a large opening distance, has the function of forced disconnection, and can carry a large current. Fast-acting contact: precise and reliable action, with contact self-cleaning function, small contact opening distance, and the load can be smaller than that of the slow-acting type
4. Which LA39 products have UL certification?
At present, the LA39 series does not have UL certification
5. Which LA39 products have classification society certification?
Some products of LA39-B2 series can be used as marine products
6. Can LA39-E, F, G series small buttons achieve anti-interference?
Small buttons do not produce anti-interference products for the time being
7. What is the ambient temperature of LA39 series buttons?
-25 ℃——55 ℃
8. What is the maximum thickness of the seat of the LA39-A/B?
LA39-A/B with Z1 and Z2 seats has a maximum thickness of 8mm without accessories, and with Z3, Z4, and Z5, the maximum thickness of the panel is 5mm
9. How many contact styles can be implemented in the LA39 one-layer contact module?
There are five types of 1NO, 1NC, 1NO1NC, 2NO, and 2NC
10. How many scales are there for the head of the emergency stop knob?
Q40mm和Q60mm两种
11. How many wildcard keys can be realized in the LA39-A/B/C series key buttons?
16 wildcard keys can be realized
12. What is the viewpoint between each position of the LA39-A series knobs?
The two-position knob viewpoint is -450-+450, and the three-position knob viewpoint is -450 00 +450
13. Does the LA39 series have a knob with light?
The LA39-A/B/C Series all have short handle with light knobs and no long handle with light knobs
14. Can the reset key be pulled out in any position?
Self-resetting key button, the key pull-out direction cannot be the self-reset action direction
15. Which series of LA39 can implement square buttons and knobs?
The LA39-B series is capable of implementing square buttons and knobs
16. Can the LA39-A/B/C light button change the lamp beads by itself?
No, only the illuminated module can be replaced
17. What can be achieved with the LA39-G series contacts?
Three kinds, 1NO1NC/2NO2NC/3NO3NC
18. Does the LA39-F series lighted button need an external resistor for current limiting?
The LA39-F series lighted button must be connected in series with a current limiting resistor (supplied with the shipment), otherwise the LED will be damaged
19. How can the LA39-B flat head knob be increased to IP67?
It can be equipped with an F1 enclosure to achieve IP67
20. Does the LA39 series two-position button have a self-locking structure?
No, the action of the two-position button is instantaneous
|
More on that
|
Siemens APT current transformers – precautions for the use of current transformers
1) The wiring of the current transformer should comply with the principle of series connection: that is, the primary winding resistance should be connected in series with the tested circuit, while the secondary winding resistance should be connected in series with all instrument loads
2) According to the size of the measured current, select the appropriate transformation ratio, otherwise the error will increase. At the same time, one end of the secondary side must be grounded in case ...
|
|
Siemens APT current transformer – a common form of current transformer ratio
1. Multi-tap current transformer. The primary winding remains unchanged, and when winding the secondary winding, several taps are added to obtain a plurality of different transformation ratios. For example, two taps are added to the secondary winding, K1 and K4 are 800/1A, K1 and K3 are 600/1A, and K1 and K2 are 400/1A, that is, the transformation ratio is 400-600-800/1A...
|
|
Siemens APT current transformer - working principle and characteristics of current transformer
How a current transformer works
The principle of current transformer is based on the principle of electromagnetic induction. A current transformer is composed of a closed core and windings. It has a small number of turns on the primary side winding, stringed in the line where the current needs to be measured, so it often has the full current of the line ...
|
|
Siemens APT Relays – The action of high and low voltage relays and how to adjust the low voltage side
1. Disconnect the control power supply: Before making the low-voltage terminal contact adjustment, the control power supply should be disconnected first to avoid the current directly or indirectly passing through the relay contact, and avoid electric shock or damage to the relay.
2. Open the relay cover: Open the relay cover, you can see the inside of the relay.
|
|
Siemens APT Current Transformer - The difference between voltage transformer and current transformer
The difference between the voltage transformer and the current transformer in terms of effect principle The primary difference is that the operating conditions are very different during normal operation, and the main performance is as follows:
1) The current transformer can be short-circuited twice, but it cannot be opened; The voltage transformer can be opened twice, but it must not be short-circuited
2) ...
|
|
Siemens APT current transformers – measures to reduce errors
The excitation current is the main cause of the error of the current transformer, so reducing the excitation current can reduce the error
(1) The core is made of materials with high permeability, because the magnetic properties of the core not only affect the ratio difference and angular difference, but also affect the saturation multiple.
(2) Increase the cross-section of the iron core and shorten the magnetic circuit.
|
|
Siemens APT current transformer - what need to be paid attention to in the use of current transformer
1. The secondary side of the current transformer shall not be open when working. Due to the small secondary impedance of the current transformer, the secondary side of the current transformer is close to the short-circuit state during normal operation. When the secondary side is open, a high voltage will be induced, which endangers the safety of people and equipment.
2. Electricity ...
|
|
Siemens APT Relays - Installation Precautions for High and Low Voltage Relays
1. Choose the right relay: When choosing a high and low voltage relay, you should choose the right product according to your needs, such as selecting according to the rated voltage, current and other information
2. Installation location: high and low voltage relays should be installed in dry, ventilated, non-corrosive gas, less dusty areas, ...
|
|
Introduction to the characteristics of Siemens APT relays - solid state relays
Solid state relay is a non-contact electronic switch with isolation function, no mechanical contact parts in the switching process, so in addition to having the same function as electromagnetic relay, solid state relay also has logic circuit compatibility, vibration resistance and mechanical impact resistance, unlimited installation position, and good anti-...
|
|
Siemens APT current transformer – the basis for whether the current transformer is damaged or the measurement is inaccurate
1. The inspection basis for whether the current transformer is damaged:
1. The basis for checking whether the polarity is damaged:
The primary winding of the current transformer is marked P1 and P2, and the secondary winding is marked as S1 and S2. If P1 and S1 are the same name, then this sign is called reduced polarity. Primary current from P1 ...
|
|
Siemens APT PB3 series of quick-fit pushbuttons wins CAIMRS "Automation Innovation Award"
On August 26, the CAIMRS2022 China Automation + Digital Industry Annual Conference was held in Beijing. Based on the fields of automation, digitalization, industrial robotics and industrial interconnection, this conference shared top digital innovation ideas, discussed the latest trends in the industry, and how to grasp the new round of science and technology.
|
|
Siemens APT relay - the use of solid state relay pay attention to five major matters
1. The resistive load should not exceed 60% of the rated current;
2. Overcurrent and load short circuit may cause permanent failure of the internal thyristor in SSR, so it is necessary to install a fuse or air switch, and a fuse can be used if the capacity is small;
3、 ...
|
|
Siemens APT Pushbutton Switches – How Many Types of Pushbutton Switches Are There?
There are several types of pushbutton switches:
Pushbutton switches can be classified according to the way they are protected and how they are operated. It can be divided into open type and protected type, as well as waterproof type and anti-corrosion type, etc. And explosion-proof, knob-type, key-type, emergency-type, are also its ...
|
|
Siemens APT Relays – The working principle of zero-crossing AC solid state relays
1. Working process:
AC zero-crossing solid state relays have the characteristic of turning on when the voltage crosses zero and turns off when the load current crosses zero.
Circuit diagrams, dimensions and drawings of zero-crossing AC solid state relays
When the optocoupler OPT is turned off (i.e. there is no input signal at the control end of the OPT ...
|
|
Siemens APT new x. The new product of R series relay was released
On May 8, 2019, APT held a grand online conference in Shanghai, Beijing, Guangzhou, Nanjing, Changsha and Tiantai...... and more than 20 cities across the country witnessed the new Siemens APT x. The new product of R series relay was released.
...
|
|
Siemens APT Relays – a commonly used detection method for high and low voltage relays
1. Visual inspection method: observe the appearance of the relay by the naked eye, check whether it is damaged or deformed, observe whether the contacts are tightly contacted, and whether there are copper slag and other substances attached to the contacts.
2. Parameter detection method: use test instruments to detect the parameters of the relay, such as: ...
|
|
Siemens APT relay - the cause and solution of the fault of the high-voltage relay
1. Some common faults of high-voltage relay coils
1. The common fault cause of the coil is often disconnected: whether the ultrasonic wave is used to clean the high-voltage relay, or whether the overvoltage is added to the coil will also promote the probability of the coil being disconnected.
2 ...
|
|
TL series police lights frequently asked questions
1. How many light sources are there for the TL-70 police light?
There are 3 types, namely LED, incandescent and xenon.
2. What are the colors of the TL-70 police light?
There are 5 types, which are red, yellow, green, blue, and white.
3. What are the types of TL-70 police lights?
3 ...
|
|
Siemens APT current transformer - classification of current transformer and its function
1. Current transformers are classified according to the installation method
According to the installation method, the current transformer can be divided into through-type current transformer, pillar type current transformer, bushing type current transformer, and busbar type current transformer.
Through-type current transformer: used to pass through the screen or wall...
|
|
Siemens APT Relays – Testing of Relays
(1) Measure the resistance of the contact: use the resistance of the multimeter to measure the resistance of the normally closed contact and the moving point, and the resistance value should be 0; The resistance between the normally open contact and the moving point is infinite. From this, it is possible to distinguish which is a normally closed contact and which is normally open.
(2) Coil resistance: multimeter R...
|
|