Siemens APT current transformer - inspection content of current transformer

Create Date: 2024-8-30 12:03:23|Source: APT/Siemens Shanghai Ergong

1. Regularly check whether the current transformer is overheated, check whether there is discoloration in the terminal, and check whether there are sundries in the terminal box.

2. Check whether there is oil leakage in the oil level gauge in time to ensure that the oil level meets the use standard, and there is no oil leakage, and comprehensively clean the porcelain part to prevent discharge and rupture.

3. Regularly inspect the insulation of the current transformer, check the oil quality of the oil-filled current transformer, and discharge the oil according to the actual situation.

4. When checking the ammeter, the three-phase indication value is comprehensively checked to prevent overload operation and ensure that it is within the specified range.

5. Carefully check the goodness of the grounding wire on the secondary side to ensure that there is no fracture, fix the loose part, and the secondary side of the current transformer in operation shall not be opened.

6. Check the output current, if there is a large current, check whether there are alarm signals such as broken wire and differential current crossing the line.

7. Check the reliability of the grounding of the current transformer.

8. Ensure that the operating temperature of the current transformer is below 50°C.

9. If the insulation breakdown phenomenon of the current transformer is caused by factors such as overvoltage or moisture, it is necessary to repair the damaged current transformer as it is.

10. After the current transformer is repaired, it is necessary to conduct the test in time, and the inspection can only be used after the inspection meets the requirements.
Siemens APT current transformer - inspection content of current transformer

More on that
Siemens APT – X-Series Control Box FAQ Siemens APT – X-Series Control Box FAQ

1. The control box is made of ABS and PC, which material has better flame retardant performance? ABS has good flame retardant performance. 2. What are the certifications for the control box? 3C & CE (for unperforated control box only) 3. What is the color of the grey cabinet of the control box? Work...

Siemens APT Relays – Components of Solid State Relays Siemens APT Relays – Components of Solid State Relays

Solid state relays consist of three parts: the input circuit, the isolation (coupling), and the output circuit. Input circuitry According to the different categories of input voltage, the input circuit can be divided into three types: DC input circuit, AC input circuit and AC and DC input circuit. Some input control circuits are also ...

Siemens APT current transformer - classification of current transformer and its function Siemens APT current transformer - classification of current transformer and its function

1. Current transformers are classified according to the installation method According to the installation method, the current transformer can be divided into through-type current transformer, pillar type current transformer, bushing type current transformer, and busbar type current transformer. Through-type current transformer: used to pass through the screen or wall...

Siemens apt - TL series police lights frequently asked questions Siemens apt - TL series police lights frequently asked questions

1. How many light sources are there for the TL-70 police light? There are 3 types, namely LED, incandescent and xenon. 2. What are the colors of the TL-70 police light? There are 5 types, which are red, yellow, green, blue, and white. 3. What are the types of TL-70 police lights? 3 ...

Siemens APT current transformer – precautions for current transformers Siemens APT current transformer – precautions for current transformers

1. Before the installation of the open current transformer, it must be connected to the meter (or other measuring devices) for the second time to ensure that the transformer is not open for the second time; 2. Place all the open current transformers connected to the secondary line on the site and wait for installation; 3. If the on-site bus is electrical...

Siemens APT current transformers – measures to reduce errors Siemens APT current transformers – measures to reduce errors

The excitation current is the main cause of the error of the current transformer, so reducing the excitation current can reduce the error (1) The core is made of materials with high permeability, because the magnetic properties of the core not only affect the ratio difference and angular difference, but also affect the saturation multiple. (2) Increase the cross-section of the iron core and shorten the magnetic circuit.

Siemens APT Relays – the solution to common faults in solid state relays Siemens APT Relays – the solution to common faults in solid state relays

1. The simplest and most effective way is to use a new solid state relay. 2. The other is to determine the voltage of the coil to avoid the voltage provided by the coil being less than the operating voltage. 3. Check whether the polarity is reversed. 4. Reasonable power-on time for the solid state relay coil, if ...

Siemens APT Relays – The difference between solid state relays and intermediate relays Siemens APT Relays – The difference between solid state relays and intermediate relays

First, the solid-state relay has no contacts and coils in the structure, which can be opened and closed at a high frequency and will not produce sparks, and has a long service life; Second, the intermediate relay is generally only used for the control loop, and cannot work with load, and will make a "pop" sound when it is sucked in; ...

Siemens APT limit switches – what are the limits used for? Siemens APT limit switches – what are the limits used for?

daily life There are many applications of travel switches, and it is found in many electrical appliances. So what does such a simple switch do? It mainly plays the role of chain protection. The most common example is its use in washing machines and tape recorders (VCRs). ...

Siemens APT Relays – How to Choose Relays? Siemens APT Relays – How to Choose Relays?

1. The type and series of relay selection First of all, the type of relay is selected according to the work requirements of the object to be controlled or protected, and then the appropriate series is selected according to the sensitivity or accuracy requirements. When choosing a series, you should also pay attention to the compatibility of the relay with the system. (1) ...

TL series police lights frequently asked questions TL series police lights frequently asked questions

1. How many light sources are there for the TL-70 police light? There are 3 types, namely LED, incandescent and xenon. 2. What are the colors of the TL-70 police light? There are 5 types, which are red, yellow, green, blue, and white. 3. What are the types of TL-70 police lights? 3 ...

Siemens APT Relays – What should I pay attention to when selecting relays? Siemens APT Relays – What should I pay attention to when selecting relays?

1. When selecting a relay, it is necessary to understand the load and type of its contact, because the contact method of the relay of the same model is different, with multiple groups of contacts and single group contacts. When selecting a relay, you can choose the type of contact. 2. And in the peach ...

Siemens APT Current Transformers – How to view current transformers Siemens APT Current Transformers – How to view current transformers

1. Standardize current transformer: the top of the transformer verification is used as a standardizer, and the accuracy is usually more than two grades higher than that of the tested. 2. Load box: imitate the practice operation status of the tested transformer. 3. Transformer ...

Siemens APT current transformer – the basis for whether the current transformer is damaged or the measurement is inaccurate Siemens APT current transformer – the basis for whether the current transformer is damaged or the measurement is inaccurate

1. The inspection basis for whether the current transformer is damaged: 1. The basis for checking whether the polarity is damaged: The primary winding of the current transformer is marked P1 and P2, and the secondary winding is marked as S1 and S2. If P1 and S1 are the same name, then this sign is called reduced polarity. Primary current from P1 ...

Siemens APT Relays – What are the types of protection relays? Siemens APT Relays – What are the types of protection relays?

Overcurrent Relay (OCR) It operates when a certain value or greater of current flows through. There are two elements: overcurrent detection (known as a timing element) and short-circuit current detection (as an instantaneous element). Earth Fault Overcurrent Relays (OCGR, GR) While...

Siemens APT LA39 series button FAQ Siemens APT LA39 series button FAQ

1. What are the installation methods of LA39-A/B/C button? There are five types in total: the Z1 diagonal screw unit, the Z2 straight screw unit, the Z3 nut device with fastening screws, the Z4 nut device without fastening screws, and the Z5 quick and convenient one-handed device 2. LA39 series products can be used ...

Siemens APT Relays - What are the relays that burn out? Siemens APT Relays - What are the relays that burn out?

1. The position of the auxiliary contact is not suitable. After the switch has been tripped, the mechanical part has moved, worn phenomenon, resulting in the auxiliary contact position offset to the correct position, in the protection action tripping, when the auxiliary contact is not disconnected, the outlet electrical appliances, electrical appliances, relays have returned, and it is ...

Siemens APT Relays - Selection Method for Solid State Relays Siemens APT Relays - Selection Method for Solid State Relays

1. When selecting the solid-state relay used in the printed circuit board with small current specifications, because the lead terminal is made of high thermal conductivity material, the soldering should be carried out under the condition that the temperature is less than 250 °C and the time is less than 10S.

Siemens APT current transformer – wiring method of current transformer Siemens APT current transformer – wiring method of current transformer

1. The single wiring mode can only feedback the status of single-phase current. 2. Three-phase complete star wiring, usually used in transformer differential protection wiring. 3. The two-phase incomplete star wiring method is used frequently in daily work. 4. The two phases ...

Siemens APT Relays – Principles and characteristics of photorelays Siemens APT Relays – Principles and characteristics of photorelays

When the input quantity (such as voltage, current, temperature, etc.) reaches the specified value, the controlled output circuit is turned on or off an electrical appliance. It can be divided into two categories: electrical (such as current, voltage, frequency, power, etc.) relays and non-electrical (such as temperature, pressure, speed, etc.) relays. With action ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top